Charged Reviews

Quick reference

Hoymiles HMeter-CT-S120-RW Single-Phase Smart Meter

Model: HMeter-CT-S120-RW · SKU: Not documented

Prepared Nov 12, 2026

Common specifications

Device type
Single-Phase smart meter with current transformers, DIN railSource [1]
Max switched load (A)Not documented
Max switched load (W)Not documented
Measurement channels
Single-Phase, grid type 1P2WSource [1]
Current sensors
Current transformer, 1 m cableSource [1]
Current rating
120 ASource [1]
Voltage range
100 to 277 VSource [1]
Accuracy
1 %Source [1]
Communications
WLAN (Wi-Fi 802.11 b/g/n), Modbus TCP; RS-485, Modbus RTU; BLE 5.0Source [1]
DisplayNot documented
Power input
Power consumption 2 WSource [1]
Mounting
Snap-on DIN 35 railSource [1]
Safety listingNot documented
Weight
0.07 kg0.16 lb convertedCalculatedSource [1]
Dimensions
68.5 D × 19 W × 94.5 H mm2.7 D × 0.75 W × 3.72 H in convertedSource [1]
Enclosure volume0.12 L** Calculated from recorded external dimensions
Warranty termNot documented

All recorded specifications

Accuracy
1 %Documented claim
Conditions

Active power accuracy, printed as "Active power ±1% (conforming to IEC 62053-21 Class 1)"; the same table prints reactive power ±2%, voltage ±0.5% and current ±0.5% from 4 to 120 A.

Location: PDF page 2, Technical Specifications, Measurement Accuracy, Active power

Active power accuracy, printed as "Active power ±1% (conforming to IEC 62053-21 Class 1)"; the same table prints reactive power ±2%, voltage ±0.5% and current ±0.5% from 4 to 120 A.

Location: PDF page 2, Technical Specifications, Measurement Accuracy, Active power

[1]
Communications
WLAN (Wi-Fi 802.11 b/g/n), Modbus TCP; RS-485, Modbus RTU; BLE 5.0Documented claim
Conditions

Printed as "Supported communication interface WLAN / RS-485", "Port protocol Modbus TCP / Modbus RTU", "Wi-Fi 802.11 b/g/n" and "Bluetooth protocol BLE 5.0"; the default baud rate is printed as 9600.

Location: PDF page 2, Technical Specifications, Communication Specifications

Printed as "Supported communication interface WLAN / RS-485", "Port protocol Modbus TCP / Modbus RTU", "Wi-Fi 802.11 b/g/n" and "Bluetooth protocol BLE 5.0"; the default baud rate is printed as 9600.

Location: PDF page 2, Technical Specifications, Communication Specifications

[1]
Current rating
120 ADocumented claim
Conditions

Printed as "Current range 0 to 120 A".

Location: PDF page 2, Technical Specifications, Electrical Specifications, Current range

Printed as "Current range 0 to 120 A".

Location: PDF page 2, Technical Specifications, Electrical Specifications, Current range

[1]
Current sensors
Current transformer, 1 m cableDocumented claim
Conditions

Printed as "Current transformer cable length 1 m"; the features print a quick-connect design for the CT.

Location: PDF page 2, Technical Specifications, Mechanical Specifications, Current transformer cable length

Printed as "Current transformer cable length 1 m"; the features print a quick-connect design for the CT.

Location: PDF page 2, Technical Specifications, Mechanical Specifications, Current transformer cable length

[1]
Device type
Single-Phase smart meter with current transformers, DIN railDocumented claim
Conditions

Printed as "Grid type 1P2W", "Mounting mode Snap-on By DIN 35 Rail" and "Current transformer cable length 1 m".

Location: PDF page 2, Technical Specifications, Electrical Specifications, Grid type; Mechanical Specifications

Printed as "Grid type 1P2W", "Mounting mode Snap-on By DIN 35 Rail" and "Current transformer cable length 1 m".

Location: PDF page 2, Technical Specifications, Electrical Specifications, Grid type; Mechanical Specifications

[1]
Dimensions
68.5 D × 19 W × 94.5 H mm2.7 D × 0.75 W × 3.72 H in convertedDocumented claim
Conditions

Printed as "19 × 94.5 × 68.5 mm", width by height by depth.

Location: PDF page 2, Technical Specifications, Mechanical Specifications, Dimensions (W × H × D)

Printed as "19 × 94.5 × 68.5 mm", width by height by depth.

Location: PDF page 2, Technical Specifications, Mechanical Specifications, Dimensions (W × H × D)

[1]
Enclosure
IP20Documented claim
Conditions

Printed as "Enclosure protection rating IP20".

Location: PDF page 2, Technical Specifications, Mechanical Specifications, Enclosure protection rating

Printed as "Enclosure protection rating IP20".

Location: PDF page 2, Technical Specifications, Mechanical Specifications, Enclosure protection rating

[1]
Measurement channels
Single-Phase, grid type 1P2WDocumented claim
Conditions

Printed as "Grid type 1P2W".

Location: PDF page 2, Technical Specifications, Electrical Specifications, Grid type

Printed as "Grid type 1P2W".

Location: PDF page 2, Technical Specifications, Electrical Specifications, Grid type

[1]
Mounting
Snap-on DIN 35 railDocumented claim
Conditions

Printed as "Mounting mode Snap-on By DIN 35 Rail" and "DIN-35 rail snap-on mounting supports quick deployment".

Location: PDF page 2, Technical Specifications, Mechanical Specifications, Mounting mode; PDF page 1, features

Printed as "Mounting mode Snap-on By DIN 35 Rail" and "DIN-35 rail snap-on mounting supports quick deployment".

Location: PDF page 2, Technical Specifications, Mechanical Specifications, Mounting mode; PDF page 1, features

[1]
Operating temperature
-40 to 70 °C-40 to 158 °F convertedDocumented claim
Conditions

Printed as "Operating temperature range -40℃ to +70℃".

Location: PDF page 2, Technical Specifications, Mechanical Specifications, Operating temperature range

Printed as "Operating temperature range -40℃ to +70℃".

Location: PDF page 2, Technical Specifications, Mechanical Specifications, Operating temperature range

[1]
Power input
Power consumption 2 WDocumented claim
Conditions

Printed as "Power consumption 2 W"; frequency 50/60 Hz, overvoltage category CAT III.

Location: PDF page 2, Technical Specifications, Electrical Specifications, Power consumption

Printed as "Power consumption 2 W"; frequency 50/60 Hz, overvoltage category CAT III.

Location: PDF page 2, Technical Specifications, Electrical Specifications, Power consumption

[1]
Voltage range
100 to 277 VDocumented claim
Conditions

Printed as "Input voltage range 100 to 277 V".

Location: PDF page 2, Technical Specifications, Electrical Specifications, Input voltage range

Printed as "Input voltage range 100 to 277 V".

Location: PDF page 2, Technical Specifications, Electrical Specifications, Input voltage range

[1]
Weight
0.07 kg0.16 lb convertedCalculated71 g / 1000 g/kg = 0.071 kg
Conditions

Printed as "Weight 71 g" (written in kg).

Location: PDF page 2, Technical Specifications, Mechanical Specifications, Weight

Printed as "Weight 71 g" (written in kg).

Location: PDF page 2, Technical Specifications, Mechanical Specifications, Weight

[1]

Warranty

Certificate records

No records documented.

Sources and revisions