Charged Reviews

Quick reference

Hoymiles HiSwitch-63T-G3 Backup Switch

Model: HiSwitch-63T-G3 · SKU: Not documented

Prepared Nov 12, 2026

Common specifications

Current rating
63 ASource [1]
Voltage rating
380/400/415 V ACSource [1]
Poles
4P + PESource [1]
Operation
Automatic switchover to backup; manual or automatic reclosing; bypass functionSource [1]
Input sourcesNot documented
Transfer time
<10 msSource [1]
Enclosure
IP20Source [1]
Safety listingNot documented
Mounting
DIN-rail mountingSource [1]
Weight
0.76 kg1.68 lb convertedCalculatedSource [1]
Dimensions
79 D × 124 W × 100 H mm3.1 D × 4.88 W × 3.94 H in convertedSource [1]
Enclosure volume0.98 L** Calculated from recorded external dimensions
Warranty termNot documented

All recorded specifications

AC configuration
three-phase (3L/N/PE)Documented claim
Conditions

Printed as "3L/N/PE" in the HiSwitch-63T-G3 column of "Grid form".

Location: PDF page 2, Technical Specifications, HiSwitch-63T-G3 column (column 2 of 2), Basic Data, Grid form

Printed as "3L/N/PE" in the HiSwitch-63T-G3 column of "Grid form".

Location: PDF page 2, Technical Specifications, HiSwitch-63T-G3 column (column 2 of 2), Basic Data, Grid form

[1]
AC frequency
50/60Documented claim
Conditions

Printed once for both models as "Nominal AC frequency (Hz) 50/60".

Location: PDF page 2, Technical Specifications, HiSwitch-63T-G3 column (column 2 of 2), Basic Data, Nominal AC frequency (Hz)

Printed once for both models as "Nominal AC frequency (Hz) 50/60".

Location: PDF page 2, Technical Specifications, HiSwitch-63T-G3 column (column 2 of 2), Basic Data, Nominal AC frequency (Hz)

[1]
Certifications (as printed)
CE; RCM; IEC 60898-1; IEC 61326-1; IEC 61000-6-2/3Documented claim
Conditions

Printed once for both models as "Certification CE, RCM, IEC 60898-1, IEC 61326-1, IEC 61000-6-2/3", with metering accuracy class I and EMC class B. Manufacturer claims; no issuer directory was checked.

Location: PDF page 2, Technical Specifications, HiSwitch-63T-G3 column (column 2 of 2), General, Certification

Printed once for both models as "Certification CE, RCM, IEC 60898-1, IEC 61326-1, IEC 61000-6-2/3", with metering accuracy class I and EMC class B. Manufacturer claims; no issuer directory was checked.

Location: PDF page 2, Technical Specifications, HiSwitch-63T-G3 column (column 2 of 2), General, Certification

[1]
Communications
RS485 (RJ45), up to 100 mDocumented claim
Conditions

Printed once for both models as "Communication distance (m) ≤ 100", "Communication interface RS485" and "Interface form RJ45".

Location: PDF page 2, Technical Specifications, HiSwitch-63T-G3 column (column 2 of 2), General, Communication interface

Printed once for both models as "Communication distance (m) ≤ 100", "Communication interface RS485" and "Interface form RJ45".

Location: PDF page 2, Technical Specifications, HiSwitch-63T-G3 column (column 2 of 2), General, Communication interface

[1]
Compatible series
Hoymiles HiOne-(8-20)T-G3Documented claim
Conditions

Printed as "HiOne-(8-20)T-G3" in the HiSwitch-63T-G3 column of "Compatible inverters".

Location: PDF page 2, Technical Specifications, HiSwitch-63T-G3 column (column 2 of 2), General, Compatible inverters

Printed as "HiOne-(8-20)T-G3" in the HiSwitch-63T-G3 column of "Compatible inverters".

Location: PDF page 2, Technical Specifications, HiSwitch-63T-G3 column (column 2 of 2), General, Compatible inverters

[1]
Current rating
63 ADocumented claim
Conditions

Printed as "63" in the HiSwitch-63T-G3 column of "Nominal AC current (A)".

Location: PDF page 2, Technical Specifications, HiSwitch-63T-G3 column (column 2 of 2), Basic Data, Nominal AC current (A)

Printed as "63" in the HiSwitch-63T-G3 column of "Nominal AC current (A)".

Location: PDF page 2, Technical Specifications, HiSwitch-63T-G3 column (column 2 of 2), Basic Data, Nominal AC current (A)

[1]
Device type
Backup switch for HiOne inverters: whole-home backup with bypass, a circuit breaker with short circuit and overload protection, energy metering and a built-in CTDocumented claim
Conditions

Printed as "Function Short circuit protection Integrated Overload protection Integrated Circuit breaker function Integrated Energy metering Integrated Whole home backup function Integrated Bypass function Integrated Manual / Automatic reclosing Integrated Built-in CT Integrated" under the datasheet heading "BACKUP SWITCH".

Location: PDF page 2, Technical Specifications, HiSwitch-63T-G3 column (column 2 of 2), Function

Printed as "Function Short circuit protection Integrated Overload protection Integrated Circuit breaker function Integrated Energy metering Integrated Whole home backup function Integrated Bypass function Integrated Manual / Automatic reclosing Integrated Built-in CT Integrated" under the datasheet heading "BACKUP SWITCH".

Location: PDF page 2, Technical Specifications, HiSwitch-63T-G3 column (column 2 of 2), Function

[1]
Dimensions
79 D × 124 W × 100 H mm3.1 D × 4.88 W × 3.94 H in convertedDocumented claim
Conditions

Printed as "124 × 100 × 79" in the HiSwitch-63T-G3 column, width by height by depth.

Location: PDF page 2, Technical Specifications, HiSwitch-63T-G3 column (column 2 of 2), General, Dimensions (W × H × D [mm])

Printed as "124 × 100 × 79" in the HiSwitch-63T-G3 column, width by height by depth.

Location: PDF page 2, Technical Specifications, HiSwitch-63T-G3 column (column 2 of 2), General, Dimensions (W × H × D [mm])

[1]
Enclosure
IP20Documented claim
Conditions

Printed once for both models as "Protection degree IP20".

Location: PDF page 2, Technical Specifications, HiSwitch-63T-G3 column (column 2 of 2), General, Protection degree

Printed once for both models as "Protection degree IP20".

Location: PDF page 2, Technical Specifications, HiSwitch-63T-G3 column (column 2 of 2), General, Protection degree

[1]
Included breakers or fuses
Circuit breaker, trip curve type C, 6 kA short circuit current; short circuit and overload protectionDocumented claim
Conditions

Printed once for both models as "Trip curve type C", "Short circuit current (kA) 6", insulation voltage 500 V and impulse withstand voltage 4 kV, with short circuit and overload protection integrated.

Location: PDF page 2, Technical Specifications, HiSwitch-63T-G3 column (column 2 of 2), Basic Data and Function

Printed once for both models as "Trip curve type C", "Short circuit current (kA) 6", insulation voltage 500 V and impulse withstand voltage 4 kV, with short circuit and overload protection integrated.

Location: PDF page 2, Technical Specifications, HiSwitch-63T-G3 column (column 2 of 2), Basic Data and Function

[1]
Mounting
DIN-rail mountingDocumented claim
Conditions

Printed once for both models as "Mounting DIN-rail mounting".

Location: PDF page 2, Technical Specifications, HiSwitch-63T-G3 column (column 2 of 2), General, Mounting

Printed once for both models as "Mounting DIN-rail mounting".

Location: PDF page 2, Technical Specifications, HiSwitch-63T-G3 column (column 2 of 2), General, Mounting

[1]
Operating temperature
-30 to 75 °C-22 to 167 °F convertedDocumented claim
Conditions

Printed once for both models as "-30 to +75".

Location: PDF page 2, Technical Specifications, HiSwitch-63T-G3 column (column 2 of 2), General, Operating temperature

Printed once for both models as "-30 to +75".

Location: PDF page 2, Technical Specifications, HiSwitch-63T-G3 column (column 2 of 2), General, Operating temperature

[1]
Operation
Automatic switchover to backup; manual or automatic reclosing; bypass functionDocumented claim
Conditions

Printed once for both models as "Whole home backup function Integrated", "Bypass function Integrated" and "Manual / Automatic reclosing Integrated".

Location: PDF page 2, Technical Specifications, HiSwitch-63T-G3 column (column 2 of 2), Function

Printed once for both models as "Whole home backup function Integrated", "Bypass function Integrated" and "Manual / Automatic reclosing Integrated".

Location: PDF page 2, Technical Specifications, HiSwitch-63T-G3 column (column 2 of 2), Function

[1]
Poles
4P + PEDocumented claim
Conditions

Printed as "4P + PE" in the HiSwitch-63T-G3 column of "Circuit Breaker poles".

Location: PDF page 2, Technical Specifications, HiSwitch-63T-G3 column (column 2 of 2), Basic Data, Circuit Breaker poles

Printed as "4P + PE" in the HiSwitch-63T-G3 column of "Circuit Breaker poles".

Location: PDF page 2, Technical Specifications, HiSwitch-63T-G3 column (column 2 of 2), Basic Data, Circuit Breaker poles

[1]
Storage temperature
-40 to 85 °C-40 to 185 °F convertedDocumented claim
Conditions

Printed once for both models as "-40 to +85".

Location: PDF page 2, Technical Specifications, HiSwitch-63T-G3 column (column 2 of 2), General, Storage temperature

Printed once for both models as "-40 to +85".

Location: PDF page 2, Technical Specifications, HiSwitch-63T-G3 column (column 2 of 2), General, Storage temperature

[1]
Transfer time
<10 msDocumented claim
Conditions

Printed once for both models as a backup switch time of less than 10 ms (written with a small form less-than sign).

Location: PDF page 2, Technical Specifications, HiSwitch-63T-G3 column (column 2 of 2), Basic Data, Back-up switch time (ms)

Printed once for both models as a backup switch time of less than 10 ms (written with a small form less-than sign).

Location: PDF page 2, Technical Specifications, HiSwitch-63T-G3 column (column 2 of 2), Basic Data, Back-up switch time (ms)

[1]
Voltage rating
380/400/415 V ACDocumented claim
Conditions

Printed as "380/400/415" in the HiSwitch-63T-G3 column of "Nominal AC voltage (V)".

Location: PDF page 2, Technical Specifications, HiSwitch-63T-G3 column (column 2 of 2), Basic Data, Nominal AC voltage (V)

Printed as "380/400/415" in the HiSwitch-63T-G3 column of "Nominal AC voltage (V)".

Location: PDF page 2, Technical Specifications, HiSwitch-63T-G3 column (column 2 of 2), Basic Data, Nominal AC voltage (V)

[1]
Weight
0.76 kg1.68 lb convertedCalculated764 g / 1000 g/kg = 0.764 kg
Conditions

Printed as "764" in the HiSwitch-63T-G3 column of "Weight (g)" (written in kg).

Location: PDF page 2, Technical Specifications, HiSwitch-63T-G3 column (column 2 of 2), General, Weight (g)

Printed as "764" in the HiSwitch-63T-G3 column of "Weight (g)" (written in kg).

Location: PDF page 2, Technical Specifications, HiSwitch-63T-G3 column (column 2 of 2), General, Weight (g)

[1]

Warranty

Certificate records

No records documented.

Sources and revisions

  1. Hoymiles HiSwitch backup switch datasheet, HiSwitch-100S-G3 and HiSwitch-63T-G3 (Region: Global, REV1.4) (November 2, 2026 capture)Official datasheet · Revision REV1.4 · Checked https://w3oss.hoymiles.com/uploadfile/1/202610/4cd931930f.pdf