Charged Reviews
Quick reference
Generac SnapRS RS802 rapid shutdown device
Model: RS802 · SKU: RS802
Prepared Nov 12, 2026
Common specifications
| Device type | Module-level rapid shutdown disconnect (one per PV module, on the negative lead)Source [1] |
|---|---|
| Rapid shutdown compliance | NEC 690.12 (2017/2020)Source [2] |
| Maximum input power | Not documented |
| Maximum input voltage | 80 VSource [1, 2] |
| Maximum input current | 15 ASource [1] |
| Output voltage | Not documented |
| Maximum output current | Not documented |
| Communications | Not documented |
| Efficiency | 99.8 %Source [2] |
| Operating temperature | |
| Enclosure | NEMA Type 6PSource [1] |
| Safety listing | UL 1741, CSA 22.2 #107.1Source [1] |
| Weight | |
| Dimensions | Not documented |
| Enclosure volume | Not documented |
| Warranty term | 25 yearsSource [2] |
All recorded specifications
| Device type | Module-level rapid shutdown disconnect (one per PV module, on the negative lead)Documented claim ConditionsOne SnapRS per PV module. Location: PDF page 9, Section 2, SnapRS Specifications One SnapRS per PV module. Location: PDF page 9, Section 2, SnapRS Specifications |
|---|---|
| Efficiency | 99.8 %Documented claim ConditionsFootnote: when used with a 50 V panel. Location: PDF page 2, PDF page 1, specifications Footnote: when used with a 50 V panel. Location: PDF page 2, PDF page 1, specifications |
| Enclosure | NEMA Type 6PDocumented claim ConditionsOne cell for the three models. Location: PDF page 9, Section 2, SnapRS Specifications One cell for the three models. Location: PDF page 9, Section 2, SnapRS Specifications |
| Maximum input current | 15 ADocumented claim ConditionsThe third column. Location: PDF page 9, Section 2, SnapRS Specifications The third column. Location: PDF page 9, Section 2, SnapRS Specifications |
| Maximum input voltage | 80 VDocumented claim ConditionsPV module maximum Voc, the third column. Generac's RS802 spec sheet (A0001520570 Rev D) prints "PV MODULE MAX VOC: 75 V" instead; the manual's value is recorded. Location: PDF page 9, Section 2, SnapRS Specifications PV module maximum Voc, the third column. Generac's RS802 spec sheet (A0001520570 Rev D) prints "PV MODULE MAX VOC: 75 V" instead; the manual's value is recorded. Location: PDF page 9, Section 2, SnapRS Specifications Official installation manual · Generac Installation Manual for PV Link and SnapRS (S2502, RS801, RS801A, RS802) (November 3, 2026 capture)Official datasheet · Generac spec sheet: SnapRS 802 Inline Disconnect Switch RS802 (A0001520570 Rev D) (November 3, 2026 capture) [1, 2] |
| Operating temperature | -40 to 70 °C-40 to 158 °F convertedDocumented claim ConditionsPrinted as -40 to 70 °C. Location: PDF page 9, Section 2, SnapRS Specifications Printed as -40 to 70 °C. Location: PDF page 9, Section 2, SnapRS Specifications |
| PV short-circuit current limit | 12 ADocumented claim ConditionsMaximum STC Isc of the string, the third column. Location: PDF page 9, Section 2, SnapRS Specifications Maximum STC Isc of the string, the third column. Location: PDF page 9, Section 2, SnapRS Specifications |
| Rapid shutdown compliance | NEC 690.12 (2017/2020)Documented claim ConditionsThe spec sheet's description. Location: PDF page 1, PDF page 1 The spec sheet's description. Location: PDF page 1, PDF page 1 |
| Safety listing | UL 1741, CSA 22.2 #107.1Documented claim ConditionsOne cell for the three models. Manufacturer claims, no issuer directory was checked. Location: PDF page 9, Section 2, SnapRS Specifications One cell for the three models. Manufacturer claims, no issuer directory was checked. Location: PDF page 9, Section 2, SnapRS Specifications |
| Weight | 0.1 kg0.23 lb convertedCalculated103 g / 1000 g/kg ConditionsPrinted as 3.6 oz / 103 g; the manual's weight cell for the three models prints 2.7 oz (76.5 g). Location: PDF page 2, PDF page 1, specifications Printed as 3.6 oz / 103 g; the manual's weight cell for the three models prints 2.7 oz (76.5 g). Location: PDF page 2, PDF page 1, specifications |
Warranty
| Warranty term | 25 yearsDocumented claim ConditionsPrinted as 25 years. Location: PDF page 2, PDF page 1, specifications Printed as 25 years. Location: PDF page 2, PDF page 1, specifications |
|---|
Certificate records
No records documented.
Sources and revisions
- Generac Installation Manual for PV Link and SnapRS (S2502, RS801, RS801A, RS802) (November 3, 2026 capture)Official installation manual · Checked https://www.generac.com/globalassets/residential/dealers--installers/generac-installer-programs/solar--battery-installer-support/s2502-pv-link--rs801-rs801a-snaprs---install-manual.pdf
- Generac spec sheet: SnapRS 802 Inline Disconnect Switch RS802 (A0001520570 Rev D) (November 3, 2026 capture)Official datasheet · Revision A0001520570 REV D 09/22 · Checked https://www.generac.com/globalassets/residential/dealers--installers/generac-installer-programs/solar--battery-installer-support/snaprs_rs802_specsheet_eng-spa_web.pdf