Generac SnapRS RS801A rapid shutdown device

Model: RS801A · SKU: RS801A

Prepared Nov 12, 2026

Common specifications

Device type
Module-level rapid shutdown disconnect (one per PV module, on the negative lead)Source [1]
Rapid shutdown complianceNot documented
Maximum input powerNot documented
Maximum input voltage
80 VSource [1]
Maximum input current
14 ASource [1]
Output voltageNot documented
Maximum output currentNot documented
CommunicationsNot documented
EfficiencyNot documented
Operating temperature
-40 to 70 °C-40 to 158 °F convertedSource [1]
Enclosure
NEMA Type 6PSource [1]
Safety listing
UL 1741, CSA 22.2 #107.1Source [1]
WeightNot documented
DimensionsNot documented
Enclosure volumeNot documented
Warranty termNot documented

All recorded specifications

Device type
Module-level rapid shutdown disconnect (one per PV module, on the negative lead)Documented claim
Conditions

One SnapRS per PV module.

Location: PDF page 9, Section 2, SnapRS Specifications

One SnapRS per PV module.

Location: PDF page 9, Section 2, SnapRS Specifications

[1]
Enclosure
NEMA Type 6PDocumented claim
Conditions

One cell for the three models.

Location: PDF page 9, Section 2, SnapRS Specifications

One cell for the three models.

Location: PDF page 9, Section 2, SnapRS Specifications

[1]
Maximum input current
14 ADocumented claim
Conditions

The second column.

Location: PDF page 9, Section 2, SnapRS Specifications

The second column.

Location: PDF page 9, Section 2, SnapRS Specifications

[1]
Maximum input voltage
80 VDocumented claim
Conditions

PV module maximum Voc, the second column.

Location: PDF page 9, Section 2, SnapRS Specifications

PV module maximum Voc, the second column.

Location: PDF page 9, Section 2, SnapRS Specifications

[1]
Operating temperature
-40 to 70 °C-40 to 158 °F convertedDocumented claim
Conditions

Printed as -40 to 70 °C.

Location: PDF page 9, Section 2, SnapRS Specifications

Printed as -40 to 70 °C.

Location: PDF page 9, Section 2, SnapRS Specifications

[1]
PV short-circuit current limit
11.2 ADocumented claim
Conditions

Maximum STC Isc of the string, the second column.

Location: PDF page 9, Section 2, SnapRS Specifications

Maximum STC Isc of the string, the second column.

Location: PDF page 9, Section 2, SnapRS Specifications

[1]
Safety listing
UL 1741, CSA 22.2 #107.1Documented claim
Conditions

One cell for the three models. Manufacturer claims, no issuer directory was checked.

Location: PDF page 9, Section 2, SnapRS Specifications

One cell for the three models. Manufacturer claims, no issuer directory was checked.

Location: PDF page 9, Section 2, SnapRS Specifications

[1]

Warranty

Certificate records

No records documented.

Sources and revisions

  1. Generac Installation Manual for PV Link and SnapRS (S2502, RS801, RS801A, RS802) (November 3, 2026 capture)Official installation manual · Checked https://www.generac.com/globalassets/residential/dealers--installers/generac-installer-programs/solar--battery-installer-support/s2502-pv-link--rs801-rs801a-snaprs---install-manual.pdf