Charged Reviews

Quick reference

Generac PWRmanager 12-relay load manager (G0080090)

Model: G0080090 · SKU: G0080090

Prepared Nov 12, 2026

Common specifications

Device type
Load manager: relays that switch home circuits on and off from the PWRview app to extend PWRcell backupSource [1]
Communications
Wi-Fi, EthernetSource [1]
Supported devices
Twelve 120 V relays (six 240 V circuits) and two HVAC relaysSource [1]
PortsNot documented
DisplayNot documented
Power inputNot documented
MountingNot documented
Enclosure
NEMA 3RSource [1]
Operating temperature
-40 to 50 °C-40 to 122 °F convertedSource [1]
WeightNot documented
Dimensions
309.88 W × 139.7 H × 449.58 L mm12.2 W × 5.5 H × 17.7 L in convertedSource [1]
Enclosure volume19.46 L** Calculated from recorded external dimensions
Warranty term
10 yearsSource [1]

All recorded specifications

Certifications (as printed)
UL-916; FCC Part 15 Class B; IC; Surge IEC 61000-4-5Documented claim
Conditions

The compliance entries; the IEC entry is a surge test method. Manufacturer claims, no issuer directory was checked.

Location: PDF page 1, Feature specifications, compliance

The compliance entries; the IEC entry is a surge test method. Manufacturer claims, no issuer directory was checked.

Location: PDF page 1, Feature specifications, compliance

[1]
Communications
Wi-Fi, EthernetDocumented claim
Conditions

The connections row.

Location: PDF page 1, Feature specifications

The connections row.

Location: PDF page 1, Feature specifications

[1]
Current rating
60 ADocumented claim
Conditions

Per relay.

Location: PDF page 1, Feature specifications

Per relay.

Location: PDF page 1, Feature specifications

[1]
Device type
Load manager: relays that switch home circuits on and off from the PWRview app to extend PWRcell backupDocumented claim
Conditions

The features list.

Location: PDF page 1, Features & Benefits

The features list.

Location: PDF page 1, Features & Benefits

[1]
Dimensions
309.88 W × 139.7 H × 449.58 L mm12.2 W × 5.5 H × 17.7 L in convertedDocumented claim
Conditions

Printed as 449.58 x 309.88 x 139.7 mm (L x W x H).

Location: PDF page 1, Feature specifications

Printed as 449.58 x 309.88 x 139.7 mm (L x W x H).

Location: PDF page 1, Feature specifications

[1]
Enclosure
NEMA 3RDocumented claim
Conditions

The enclosure row.

Location: PDF page 1, Feature specifications

The enclosure row.

Location: PDF page 1, Feature specifications

[1]
Operating temperature
-40 to 50 °C-40 to 122 °F convertedDocumented claim
Conditions

Printed as -40 to +50 °C.

Location: PDF page 1, Feature specifications

Printed as -40 to +50 °C.

Location: PDF page 1, Feature specifications

[1]
Supported devices
Twelve 120 V relays (six 240 V circuits) and two HVAC relaysDocumented claim
Conditions

The relay rows.

Location: PDF page 1, Feature specifications

The relay rows.

Location: PDF page 1, Feature specifications

[1]

Warranty

Warranty term
10 yearsDocumented claim
Conditions

A 10-year limited warranty.

Location: PDF page 1, Feature specifications

A 10-year limited warranty.

Location: PDF page 1, Feature specifications

[1]

Certificate records

No records documented.

Sources and revisions

  1. Generac spec sheet: PWRmanager Advanced Load Management G0080090 (A0002198364 Rev B) (November 3, 2026 capture)Official datasheet · Revision A0002198364 REV B · Checked https://www.generac.com/globalassets/residential/solar-power-storage/pwrcell--overview/final-pwrmanager_specsheet_revb.pdf