Common specifications

Device type
Consumption current transformer (split core)Source [1]
Max switched load (A)Not documented
Max switched load (W)Not documented
Measurement channelsNot documented
Current sensors
Split coreSource [1]
Current rating
600 ASource [1]
Voltage range
Up to 277 VAC (primary)Source [1]
Accuracy
2.5 %Source [1]
CommunicationsNot documented
DisplayNot documented
Power inputNot documented
MountingNot documented
Safety listingNot documented
WeightNot documented
DimensionsNot documented
Enclosure volumeNot documented
Warranty termNot documented

All recorded specifications

Accuracy
2.5 %Documented claim
Conditions

Printed as an error rate of less than 2.5%.

Location: PDF page 1, Specifications

Printed as an error rate of less than 2.5%.

Location: PDF page 1, Specifications

[1]
Certifications (as printed)
UL 2808 (with service entrance rating)Documented claim
Conditions

Printed as "Compliance UL 2808 certified with service entrance rating, RoHS (latest version)" in the specifications table under the CT-600-277-SPLIT column; no CE, IEC, TUV or JET mark is printed anywhere in the instruction. Manufacturer claim; no issuer directory was checked.

Location: PDF page 1, Specifications

Printed as "Compliance UL 2808 certified with service entrance rating, RoHS (latest version)" in the specifications table under the CT-600-277-SPLIT column; no CE, IEC, TUV or JET mark is printed anywhere in the instruction. Manufacturer claim; no issuer directory was checked.

Location: PDF page 1, Specifications

[1]
Compatibility
IQ Gateway Commercial Pro (a set of three)Documented claim
Conditions

Printed in the instruction's introduction.

Location: PDF page 1, Introduction

Printed in the instruction's introduction.

Location: PDF page 1, Introduction

[1]
Current rating
600 ADocumented claim
Conditions

Printed as the maximum primary current.

Location: PDF page 1, Specifications

Printed as the maximum primary current.

Location: PDF page 1, Specifications

[1]
Current sensors
Split coreDocumented claim
Conditions

Printed in the current transformer type row.

Location: PDF page 1, Specifications

Printed in the current transformer type row.

Location: PDF page 1, Specifications

[1]
Device type
Consumption current transformer (split core)Documented claim
Conditions

Printed as the instruction's title and the current transformer type row.

Location: PDF page 1, Specifications

Printed as the instruction's title and the current transformer type row.

Location: PDF page 1, Specifications

[1]
Operating temperature
-40 to 85 °C-40 to 185 °F convertedDocumented claim
Conditions

Printed as -40 to 85 °C.

Location: PDF page 1, Specifications

Printed as -40 to 85 °C.

Location: PDF page 1, Specifications

[1]
Voltage range
Up to 277 VAC (primary)Documented claim
Conditions

Printed as the primary voltage range.

Location: PDF page 1, Specifications

Printed as the primary voltage range.

Location: PDF page 1, Specifications

[1]

Warranty

Certificate records

No records documented.

Sources and revisions

  1. Enphase 600 A Consumption CT installation instruction, 140-00458-01 (November 2025) (November 3, 2026 capture)Official instruction manual · Revision 140-00458-01 · Checked https://enphase.com/download/600a-consumption-current-transformer-quick-install-guide