About brandSolar batteries, inverters and system equipment.
SKU detail
conditions: EG4 prints no SKU, part number or model code for the Load Center PDP on its legacy page or in its manual; the manual prints "Product Name EG4 Load Center".
Sources: No source on record
No spec by that name.
Units
Field
Value
Conditions
Source
Weight
16.94 kg / 37.35 lb converted
Printed as "Without Shipping 6x12x43 in (15.25x30.5x109.2cm); 37.35 lb. (16.94 kg)" (without shipping); the kilogram figure is the manual's own.
Where: Manual PDF page 9, 5. Specifications, Dimensions & Weight
Load center: pre-wired power distribution panel for paralleling two EG4 6500EX inverters (AC bypass and transfer switch, battery breakers, PV disconnects, common neutral and ground bus bars)
The manual prints "The EG4 Load Center is an out-of-the-box unit that is pre-wired for support the integration of 2 EG4 6500 Inverters and batteries for both on-grid and off-grid residential solar installations." and "Warning: The EG4 Load Center must only be used with inverters running in stationary mode (Common Neutral)"; the page says "this all-in-one unit makes paralleling 2 x EG4 6500EX inverters simple and easy".
Where: Manual PDF page 5, 2. EG4 Load Center components and features; product page description
The manual prints "Two DC Isolators (PV Disconnect) # of Poles 4 Current 25A Voltage 600V DC"; the page prints "AC Bypass Voltage: 120/240VAC Battery Protection: 2 x 100A/2-Pole breakers (Battery to Inverter Breakers) PV Disconnect: 2 x 25A Isolators (600VDC)".
Where: Manual PDF page 5, 2. EG4 Load Center components and features, Two DC Isolators; product page
EG4 lists the panel under Legacy Products and titles its page "EG4® Load Center PDP [Legacy Product]" (captured November 1, 2026). The page prints no last-order or end-of-support date; the manual link stays posted.
AC bypass assembly: 2 breakers, 4 poles each, 63 A per pole; AC bypass current 126 A; 63 A per inverter Check note
EG4 documents differ. The manual prints 2 four-pole 63 A breakers in the AC bypass assembly; the product page lists 3 x 63A/4-Pole breakers (AC Breakers).
Printed as "AC Bypass Assembly (AC Protection and Transfer Switch) # of Breakers 2 Poles per Breaker 4 Current per Pole 63A AC Bypass Current 126A Inverter Input Current Limit 63A per inverter Inverter Output Current Limit 63A per inverter Voltage 120/240VAC".
Where: Manual PDF page 5, 2. EG4 Load Center components and features, AC Bypass Assembly
Sources
3 x 63A/4-Pole breakers (AC Breakers)
Printed as "What's Included 1 x Interlock Plate 1 x Ground Busbar 1 x Neutral Busbar 2 x 100A/2-Pole breakers (Battery to Inverter Breakers) 2 x 25A/4-Pole isolators (PV Disconnects) 3 x 63A/4-Pole breakers (AC Breakers)"
120/240VAC (AC bypass); 60VDC (battery breakers); 600V DC (PV isolators)
The manual prints "AC Bypass Assembly (AC Protection and Transfer Switch) # of Breakers 2 Poles per Breaker 4 Current per Pole 63A AC Bypass Current 126A Inverter Input Current Limit 63A per inverter Inverter Output Current Limit 63A per inverter Voltage 120/240VAC", "Two DC Breakers (Battery Protection and Disconnect) # of Poles 2 Current 125A per pole, 250A total Voltage 60VDC" and "Two DC Isolators (PV Disconnect) # of Poles 4 Current 25A Voltage 600V DC"; the page prints "AC Bypass Voltage: 120/240VAC Battery Protection: 2 x 100A/2-Pole breakers (Battery to Inverter Breakers) PV Disconnect: 2 x 25A Isolators (600VDC)".
Where: Manual PDF page 5, 2. EG4 Load Center components and features
Location: 2. Components and features; 5. Specifications
Retrieved Nov 1, 2026
EG4's user manual linked from the Load Center PDP legacy page (file uploaded 2024/05; version 1.0.1, copyright 2023), captured on November 1, 2026 at 19:35 UTC with the paced research fetcher (HTTP 200). It prints the pre-assembled breaker and isolator ratings, wiring, enclosure and weight; the outline dimensions are printed without saying which figure is height, width or depth. Manufacturer document, not an independent test.
Archived copies
Archived copy of a document published by EG4 Electronics. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
EG4's own page for the Load Center PDP under Legacy Products, titled "[Legacy Product]", captured on November 1, 2026 at 19:22 UTC with the paced research fetcher (HTTP 200). It prints no SKU or model code; it prints specifications and an included-parts list and links the manual. Manufacturer claims, not independent tests.
Earlier revisions, archived captures and copies published by someone other than the manufacturer. Every one stays reachable.
Archived documents
EG4 Load Center User Manual, version 1.0.1 (November 1, 2026 capture)
Archived copy of a document published by EG4 Electronics. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].