Charged Reviews
Quick reference
EcoFlow Power Link
Model: EF-PK-O05-1 · SKU: EFMM305PowerLink
Prepared Nov 12, 2026
Common specifications
| Device type | System link for the Power Kits system (sensor inputs and relays)Source [1] |
|---|---|
| Communications | Not documented |
| Supported devices | EcoFlow Power Hub, EcoFlow smart distribution panel, sensors and relaysSource [1] |
| Ports | Voltage type sensor inputs: 3 (0-35V⎓); resistance type sensor inputs: 4 (10 Ω-100 kΩ); digital input: 1; relay: 2 (Max. 42.4V⎓, 1.75A)Source [1] |
| Display | Not documented |
| Power input | EF BUS Input 12V⎓1.5A MaxSource [1] |
| Mounting | Not documented |
| Enclosure | IP20Source [1] |
| Operating temperature | |
| Weight | |
| Dimensions | |
| Enclosure volume | 0.31 L** Calculated from recorded external dimensions |
| Warranty term | Not documented |
All recorded specifications
| Device type | System link for the Power Kits system (sensor inputs and relays)Documented claim ConditionsPrinted as "EcoFlow Power Link integrates data from EcoFlow Power Hub, EcoFlow smart distribution panel, sensors, and customized relays in your RV/marine system to central control." Location: Overview Printed as "EcoFlow Power Link integrates data from EcoFlow Power Hub, EcoFlow smart distribution panel, sensors, and customized relays in your RV/marine system to central control." Location: Overview |
|---|---|
| Dimensions | 137 D × 31 D × 74 D mm5.39 D × 1.2 D × 2.9 D in convertedDocumented claim ConditionsPrinted as "137×31×74 mm (5.4×1.2×2.9 in.)" with no axes named; kept in the printed order. Location: Technical Specifications, General Printed as "137×31×74 mm (5.4×1.2×2.9 in.)" with no axes named; kept in the printed order. Location: Technical Specifications, General |
| Enclosure | IP20Documented claim ConditionsPrinted as "IP Rating IP20". Location: Technical Specifications, Environment Printed as "IP Rating IP20". Location: Technical Specifications, Environment |
| Operating temperature | -25 to 50 °C-13 to 122 °F convertedDocumented claim ConditionsPrinted as "–25℃ to 50℃ (–13℉ to 122℉)". Location: Technical Specifications, Environment Printed as "–25℃ to 50℃ (–13℉ to 122℉)". Location: Technical Specifications, Environment |
| Ports | Voltage type sensor inputs: 3 (0-35V⎓); resistance type sensor inputs: 4 (10 Ω-100 kΩ); digital input: 1; relay: 2 (Max. 42.4V⎓, 1.75A)Documented claim ConditionsThe sensor, digital input and relay rows, as printed (the relay row is headed "Number of Inputs 2"). Location: Technical Specifications The sensor, digital input and relay rows, as printed (the relay row is headed "Number of Inputs 2"). Location: Technical Specifications |
| Power input | EF BUS Input 12V⎓1.5A MaxDocumented claim ConditionsPrinted as "EF BUS Input 12V⎓1.5A Max"; EF BUS Output is printed as "12V⎓1.33A Max". Location: Technical Specifications, General Printed as "EF BUS Input 12V⎓1.5A Max"; EF BUS Output is printed as "12V⎓1.33A Max". Location: Technical Specifications, General |
| Supported devices | EcoFlow Power Hub, EcoFlow smart distribution panel, sensors and relaysDocumented claim ConditionsAs the overview names them. Location: Overview As the overview names them. Location: Overview |
| Weight | 0.12 kg0.26 lb convertedCalculated120 g / 1000 g/kg ConditionsPrinted as "Approx. 120 g (0.26 lb)". Location: Technical Specifications, General Printed as "Approx. 120 g (0.26 lb)". Location: Technical Specifications, General |
Warranty
Certificate records
No records documented.
Sources and revisions
- EcoFlow Power Link User Manual (online) (November 3, 2026 capture)Official user manual · Checked https://manuals.ecoflow.com/us/product/power-link?lang=en_US
- EcoFlow US store page: EcoFlow Power Link (November 3, 2026 capture)Official product page · Checked https://us.ecoflow.com/products/power-link