Common specifications

Current rating
100 ASource [1]
Voltage rating
40 to 60 VSource [1]
Terminal sizeNot documented
TerminalsNot documented
MaterialNot documented
Dimensions
316 D × 70 D × 143 D mm12.4 D × 2.8 D × 5.63 D in convertedSource [1]
Enclosure volume3.16 L** Calculated from recorded external dimensions
Warranty termNot documented

All recorded specifications

Current rating
100 ADocumented claim
Conditions

Printed as "40-60V⎓100A Max" for the POWER HUB port, the BATTERY 1/2 ports and the BATTERY 3 / MULTI CONNECTION port; the two 48V DC outputs are printed as "40-60V⎓ 55A Max".

Location: Technical Specifications, DC Input/Output

Printed as "40-60V⎓100A Max" for the POWER HUB port, the BATTERY 1/2 ports and the BATTERY 3 / MULTI CONNECTION port; the two 48V DC outputs are printed as "40-60V⎓ 55A Max".

Location: Technical Specifications, DC Input/Output

[1]
Device type
Battery expansion dock for the Power Kits systemDocumented claim
Conditions

Printed as "EcoFlow Power Dock enables adding up to 9 EcoFlow LFP batteries to the Power Kits system with one EcoFlow Power Hub. It can also connect with two 48V DC appliances."

Location: Overview

Printed as "EcoFlow Power Dock enables adding up to 9 EcoFlow LFP batteries to the Power Kits system with one EcoFlow Power Hub. It can also connect with two 48V DC appliances."

Location: Overview

[1]
Dimensions
316 D × 70 D × 143 D mm12.4 D × 2.8 D × 5.63 D in convertedDocumented claim
Conditions

Printed as "316×70×143 mm (12.4×2.8×5.6 in.)" with no axes named; kept in the printed order.

Location: Technical Specifications, General

Printed as "316×70×143 mm (12.4×2.8×5.6 in.)" with no axes named; kept in the printed order.

Location: Technical Specifications, General

[1]
Enclosure
IP20Documented claim
Conditions

Printed as "IP Rating IP20".

Location: Technical Specifications, Other

Printed as "IP Rating IP20".

Location: Technical Specifications, Other

[1]
Operating temperature
-25 to 45 °C-13 to 113 °F convertedDocumented claim
Conditions

Printed as "–25°C to 45°C (–13°F to 113°F)".

Location: Technical Specifications, Environment

Printed as "–25°C to 45°C (–13°F to 113°F)".

Location: Technical Specifications, Environment

[1]
Ports
POWER HUB port, BATTERY 1/2 ports, BATTERY 3 / MULTI CONNECTION port (each 40-60V⎓100A Max); 48V DC Output 1/2 (40-60V⎓ 55A Max)Documented claim
Conditions

The port rows as printed; the table also asks for an external switch with "Rated current >140A" and "Breaking capacity >140A".

Location: Technical Specifications, DC Input/Output

The port rows as printed; the table also asks for an external switch with "Rated current >140A" and "Breaking capacity >140A".

Location: Technical Specifications, DC Input/Output

[1]
Voltage rating
40 to 60 VDocumented claim
Conditions

Printed as "40-60V" on every port.

Location: Technical Specifications, DC Input/Output

Printed as "40-60V" on every port.

Location: Technical Specifications, DC Input/Output

[1]
Weight
1.8 kg4 lb convertedDocumented claim
Conditions

Printed as "Approx. 1.8 kg (4 lb)".

Location: Technical Specifications, General

Printed as "Approx. 1.8 kg (4 lb)".

Location: Technical Specifications, General

[1]

Warranty

Certificate records

No records documented.

Sources and revisions

  1. EcoFlow Power Dock User Manual (online) (November 3, 2026 capture)Official user manual · Checked https://manuals.ecoflow.com/us/product/power-dock?lang=en_US
  2. EcoFlow US store page: EcoFlow Power Dock (November 3, 2026 capture)Official product page · Checked https://us.ecoflow.com/products/power-dock