Charged Reviews

Quick reference

ARCO Zeus A4000-24V Low Turn On (LTO) High Output Alternator, 3.15"R Dual Foot, Rear Exit B+, External Only, Isolated Ground (4402)

Model: 4402 · SKU: 4402

Prepared Nov 12, 2026

Common specifications

Rated output current
144 ASource [2, 3]
Sustained output current
108 ANeeds confirmationSource See note below[2, 3]
System voltage
24 VSource [2, 3]
RotationNot documented
Ground type
Isolated GroundSource [2]
Mounting
3.15"R Dual Foot, Rear Exit B+Source [2]
Pulley
49mm K6 (6 groove)Source [2]
Cut-in speed (RPM)
1,072 RPMSource [3]
Maximum speed (RPM)
19,000 RPMSource [3]
Stator size
138 mm5.43 in convertedSource [3]
Regulator included
External OnlySource [2, 3]
Cooling
Dual cooling fansSource [2, 3]
EfficiencyNot documented
Operating temperature
100 M °CSource [3]
WeightNot documented
DimensionsNot documented
Enclosure volumeNot documented
Warranty termNot documented

All recorded specifications

Cooling
Dual cooling fansDocumented claim
Conditions

Printed as "Dual cooling fans" on ARCO's product page and "Dual Cooling fans" in the brochure's High Output Alternators list, which covers every Zeus high output alternator.

Location: Product page description, "Coolest operating temperatures" list; brochure, High Output Alternators list

Printed as "Dual cooling fans" on ARCO's product page and "Dual Cooling fans" in the brochure's High Output Alternators list, which covers every Zeus high output alternator.

Location: Product page description, "Coolest operating temperatures" list; brochure, High Output Alternators list

[2, 3]
Cut-in speed (RPM)
1,072 RPMDocumented claim
Conditions

Printed as "Cut-In RPM 1,072 Alternator RPM" in the A4000-24V LTO product page's Technical Specifications, which cover every part number of the page.

Location: Product page, Technical Specifications, Cut-In RPM row

Printed as "Cut-In RPM 1,072 Alternator RPM" in the A4000-24V LTO product page's Technical Specifications, which cover every part number of the page.

Location: Product page, Technical Specifications, Cut-In RPM row

[3]
Ground type
Isolated GroundDocumented claim
Conditions

Printed in the Ground Type column of the brochure row "24V 3,960 (144) 2,970 (108) 3.15"R Dual Foot, Rear Exit B+ External Only Isolated Ground 49mm K6 (6 groove) 4402".

Location: Brochure, A4000-24V LTO DETAILS table, Ground Type column for part 4402

Printed in the Ground Type column of the brochure row "24V 3,960 (144) 2,970 (108) 3.15"R Dual Foot, Rear Exit B+ External Only Isolated Ground 49mm K6 (6 groove) 4402".

Location: Brochure, A4000-24V LTO DETAILS table, Ground Type column for part 4402

[2]
Maximum speed (RPM)
19,000 RPMDocumented claim
Conditions

Printed as "Maximum Alt RPM 19,000" in the A4000-24V LTO product page's Technical Specifications.

Location: Product page, Technical Specifications, Maximum Alt RPM row

Printed as "Maximum Alt RPM 19,000" in the A4000-24V LTO product page's Technical Specifications.

Location: Product page, Technical Specifications, Maximum Alt RPM row

[3]
Mounting
3.15"R Dual Foot, Rear Exit B+Documented claim
Conditions

The housing (mount) ARCO's brochure prints for part 4402, row "24V 3,960 (144) 2,970 (108) 3.15"R Dual Foot, Rear Exit B+ External Only Isolated Ground 49mm K6 (6 groove) 4402"; ground type Isolated Ground, pulley 49mm K6 (6 groove).

Location: Brochure, A4000-24V LTO DETAILS table, Housing column for part 4402

The housing (mount) ARCO's brochure prints for part 4402, row "24V 3,960 (144) 2,970 (108) 3.15"R Dual Foot, Rear Exit B+ External Only Isolated Ground 49mm K6 (6 groove) 4402"; ground type Isolated Ground, pulley 49mm K6 (6 groove).

Location: Brochure, A4000-24V LTO DETAILS table, Housing column for part 4402

[2]
Operating temperature
100 M °CDocumented claim
Conditions

Printed as "Max Continuous Operating Temperature 100°C" with its Fahrenheit figure in the product page's Technical Specifications; ARCO prints a maximum continuous operating temperature only, no lower limit.

Location: Product page, Technical Specifications, Max Continuous Operating Temperature row

Printed as "Max Continuous Operating Temperature 100°C" with its Fahrenheit figure in the product page's Technical Specifications; ARCO prints a maximum continuous operating temperature only, no lower limit.

Location: Product page, Technical Specifications, Max Continuous Operating Temperature row

[3]
Pulley
49mm K6 (6 groove)Documented claim
Conditions

Printed in the Pulley column of the brochure row "24V 3,960 (144) 2,970 (108) 3.15"R Dual Foot, Rear Exit B+ External Only Isolated Ground 49mm K6 (6 groove) 4402".

Location: Brochure, A4000-24V LTO DETAILS table, Pulley column for part 4402

Printed in the Pulley column of the brochure row "24V 3,960 (144) 2,970 (108) 3.15"R Dual Foot, Rear Exit B+ External Only Isolated Ground 49mm K6 (6 groove) 4402".

Location: Brochure, A4000-24V LTO DETAILS table, Pulley column for part 4402

[2]
Rated output current
144 ADocumented claim
Conditions

The maximum output current ARCO prints for part 4402: its brochure's A4000-24V LTO DETAILS table row "24V 3,960 (144) 2,970 (108) 3.15"R Dual Foot, Rear Exit B+ External Only Isolated Ground 49mm K6 (6 groove) 4402" (Maximum Output column 3,960 (144)), and the product page's Technical Specifications row "Max Output (Cold, 9,000 RPM) at 27.5V 144 Amps - 3,960 Watts". Maximum output is the cold figure at 9,000 alternator RPM. The product page prints "Sustained Cruising Output (Hot, 6,000 RPM) at 27.5V 130 Amps" and "Sustained Idle Output (Hot, 3,000 RPM) at 27.5V 108 Amps". ARCO says "cold" testing was done at 71 °F and measures "hot" output after 60 minutes at 3,000 RPM under a plexiglass shield.

Location: Brochure, A4000-24V LTO DETAILS table, row for part 4402; product page, Technical Specifications, Max Output row

The maximum output current ARCO prints for part 4402: its brochure's A4000-24V LTO DETAILS table row "24V 3,960 (144) 2,970 (108) 3.15"R Dual Foot, Rear Exit B+ External Only Isolated Ground 49mm K6 (6 groove) 4402" (Maximum Output column 3,960 (144)), and the product page's Technical Specifications row "Max Output (Cold, 9,000 RPM) at 27.5V 144 Amps - 3,960 Watts". Maximum output is the cold figure at 9,000 alternator RPM. The product page prints "Sustained Cruising Output (Hot, 6,000 RPM) at 27.5V 130 Amps" and "Sustained Idle Output (Hot, 3,000 RPM) at 27.5V 108 Amps". ARCO says "cold" testing was done at 71 °F and measures "hot" output after 60 minutes at 3,000 RPM under a plexiglass shield.

Location: Brochure, A4000-24V LTO DETAILS table, row for part 4402; product page, Technical Specifications, Max Output row

[2, 3]
Regulator included
External OnlyDocumented claim
Conditions

ARCO's brochure prints the regulation of part 4402 as "External Only" (row "24V 3,960 (144) 2,970 (108) 3.15"R Dual Foot, Rear Exit B+ External Only Isolated Ground 49mm K6 (6 groove) 4402"). The product page explains: "These units will come with a terminal block and a P-Type harness. They will only work with an external regulator". A regulator is not part of an External Only unit; ARCO names its Zeus Bluetooth regulator for these.

Location: Brochure, A4000-24V LTO DETAILS table, Regulation column for part 4402; product page, Regulation notes

ARCO's brochure prints the regulation of part 4402 as "External Only" (row "24V 3,960 (144) 2,970 (108) 3.15"R Dual Foot, Rear Exit B+ External Only Isolated Ground 49mm K6 (6 groove) 4402"). The product page explains: "These units will come with a terminal block and a P-Type harness. They will only work with an external regulator". A regulator is not part of an External Only unit; ARCO names its Zeus Bluetooth regulator for these.

Location: Brochure, A4000-24V LTO DETAILS table, Regulation column for part 4402; product page, Regulation notes

[2, 3]
Stator size
138 mm5.43 in convertedDocumented claim
Conditions

Printed as "Stator Size 138mm" in the A4000-24V LTO product page's Technical Specifications.

Location: Product page, Technical Specifications, Stator Size row

Printed as "Stator Size 138mm" in the A4000-24V LTO product page's Technical Specifications.

Location: Product page, Technical Specifications, Stator Size row

[3]
Sustained output current
108 ANeeds confirmationARCO's brochure part-number table and product page print 108 A for part 4402; the brochure's 24V Specifications table prints 115 A for both 24V models. Neither names a revision that supersedes the other.
Conditions

The sustained idle output ARCO prints for part 4402: the brochure row "24V 3,960 (144) 2,970 (108) 3.15"R Dual Foot, Rear Exit B+ External Only Isolated Ground 49mm K6 (6 groove) 4402" (Sustained Idle Output column 2,970 (108); its footnote reads "*3,000 alternator RPM sustained under load and hot conditions for 1 hour.") and the product page's "Sustained Idle Output (Hot, 3,000 RPM) at 27.5V 108 Amps". The page also prints "Sustained Cruising Output (Hot, 6,000 RPM) at 27.5V 130 Amps". ARCO measures "hot" output after the alternator has run 60 minutes at 3,000 RPM under a plexiglass shield.

Location: Brochure, A4000-24V LTO DETAILS table, Sustained Idle Output column for part 4402; product page, Technical Specifications, Sustained Idle Output row

The sustained idle output ARCO prints for part 4402: the brochure row "24V 3,960 (144) 2,970 (108) 3.15"R Dual Foot, Rear Exit B+ External Only Isolated Ground 49mm K6 (6 groove) 4402" (Sustained Idle Output column 2,970 (108); its footnote reads "*3,000 alternator RPM sustained under load and hot conditions for 1 hour.") and the product page's "Sustained Idle Output (Hot, 3,000 RPM) at 27.5V 108 Amps". The page also prints "Sustained Cruising Output (Hot, 6,000 RPM) at 27.5V 130 Amps". ARCO measures "hot" output after the alternator has run 60 minutes at 3,000 RPM under a plexiglass shield.

Location: Brochure, A4000-24V LTO DETAILS table, Sustained Idle Output column for part 4402; product page, Technical Specifications, Sustained Idle Output row

[2, 3]
System voltage
24 VDocumented claim
Conditions

Printed as "Voltage 24V" in the product page's Technical Specifications and as the Voltage column of the brochure row "24V 3,960 (144) 2,970 (108) 3.15"R Dual Foot, Rear Exit B+ External Only Isolated Ground 49mm K6 (6 groove) 4402".

Location: Brochure, A4000-24V LTO DETAILS table, Voltage column; product page, Technical Specifications, Voltage row

Printed as "Voltage 24V" in the product page's Technical Specifications and as the Voltage column of the brochure row "24V 3,960 (144) 2,970 (108) 3.15"R Dual Foot, Rear Exit B+ External Only Isolated Ground 49mm K6 (6 groove) 4402".

Location: Brochure, A4000-24V LTO DETAILS table, Voltage column; product page, Technical Specifications, Voltage row

[2, 3]

Warranty

Certificate records

No records documented.

Sources and revisions

  1. ARCO Zeus Alternator Installation Guide 2025 (TECH-001 REV-B 8/18/25, arcomarine.com, October 29, 2026 capture)Official installation manual · Revision TECH-001 REV-B · 2025-08-18 · Checked https://cdn.shopify.com/s/files/1/0110/9521/2098/files/TECH-001_ARCO_Zeus_Alternator_Installation_Guide_2025.pdf?v=1755639945
  2. ARCO Zeus High Energy Collection brochure: Bluetooth Alternator Regulator & High Output Alternators (v2, arcomarine.com, October 27, 2026 capture)Official document · Revision 1001 Cat 1 Rev A · Checked https://cdn.shopify.com/s/files/1/0110/9521/2098/files/The_ARCO_Zeus_Collection_Brochure_v2_488a3d13-7f71-461e-8999-4f88397839fc.pdf?v=1762453970
  3. ARCO Marine product page: ARCO Zeus A4000-24V Low Turn On (LTO) High Output Alternator (arcomarine.com, October 27, 2026 capture)Official product page · Checked https://arcomarine.com/products/arco-zeus-24-volt-4kw-low-turn-on-lto-high-output-alternator
  4. ARCO Zeus High Output Alternator Wiring Connection Instructions (TECH001 - REV001 7/31/25, arcomarine.com, October 29, 2026 capture)Official document · Revision TECH001 - REV001 · 2025-07-31 · Checked https://cdn.shopify.com/s/files/1/0110/9521/2098/files/ARCO_Zeus_Alternator_insert_2025_V3.pdf?v=1754409647
  5. ARCO Zeus Alternator & Regulator OEM Troubleshooting Guide (TECH-002 REV-A 7/31/25, arcomarine.com, October 29, 2026 capture)Official instruction manual · Revision TECH-002 REV-A · 2025-07-31 · Checked https://cdn.shopify.com/s/files/1/0110/9521/2098/files/TECH-002_ARCO_Zeus_Alternator_Regulator_OEM_Troubleshooting_Guide.pdf?v=1755639958
  6. ARCO Zeus Installation Audit v1.0 (TECH-004 REV-A 7/31/2025, arcomarine.com, October 29, 2026 capture)Official instruction manual · Revision TECH-004 REV-A · 2025-07-31 · Checked https://cdn.shopify.com/s/files/1/0110/9521/2098/files/TECH-004_ARCO_Zeus_Installation_Audit_v1.0.pdf?v=1755639979
  7. ARCO Zeus High Energy Collection brochure (file The_ARCO_Zeus_Collection_Brochure.pdf, arcomarine.com, October 29, 2026 capture)Official document · Revision 1001 Cat 1 Rev A · Checked https://cdn.shopify.com/s/files/1/0110/9521/2098/files/The_ARCO_Zeus_Collection_Brochure.pdf?v=1743020364