Charged Reviews
Quick reference
APsmart Transmitter-PLC Dual Core (406000)
Model: Transmitter-PLC Dual Core · SKU: 406000
Prepared Nov 12, 2026

Common specifications
| Device type | Rapid shutdown transmitter (PLC), dual core (29 mm), no power supplySource [1] |
|---|---|
| Rapid shutdown compliance | NEC 2017, 2020 and 2023 (690.12); SunSpecSource [1] |
| Maximum input power | Not documented |
| Maximum input voltage | Not documented |
| Maximum input current | Not documented |
| Output voltage | Not documented |
| Maximum output current | Not documented |
| Communications | PLC; SunSpec rapid shutdown signalingSource [1] |
| Efficiency | Not documented |
| Operating temperature | |
| Enclosure | IP30Source [1] |
| Safety listing | Not documented |
| Weight | Not documented |
| Dimensions | |
| Enclosure volume | 0.13 L** Calculated from recorded external dimensions |
| Warranty term | Not documented |
All recorded specifications
| Certifications (as printed) | NEC 2017, 2020&2023 (690.12); UL1741; CSA C22.2 No. 330-17; FCC Part15; ICES-003Documented claim ConditionsThe safety and EMC compliance rows as printed. Manufacturer claims; no issuer directory was checked. Location: PDF page 2, Features & Compliance, Safety Compliance and EMC Compliance The safety and EMC compliance rows as printed. Manufacturer claims; no issuer directory was checked. Location: PDF page 2, Features & Compliance, Safety Compliance and EMC Compliance |
|---|---|
| Communications | PLC; SunSpec rapid shutdown signalingDocumented claim ConditionsPrinted as "Communication PLC"; the description prints "This solution complies with NEC 690.12 specifications for 2017, 2020&2023 and supports the SunSpec signaling for rapid shutdown." Location: PDF page 2, Main electrical data, Communication; PDF page 1, description Printed as "Communication PLC"; the description prints "This solution complies with NEC 690.12 specifications for 2017, 2020&2023 and supports the SunSpec signaling for rapid shutdown." Location: PDF page 2, Main electrical data, Communication; PDF page 1, description |
| Device type | Rapid shutdown transmitter (PLC), dual core (29 mm), no power supplyDocumented claim ConditionsThe ordering information prints "406000 29mm Dual Core Transmitter-PLC (no power supply)"; the description prints "The APsmart Rapid Shutdown System Transmitter-PLC is part of a rapid shutdown solution when paired with APsmart RSD, a PV module rapid shutdown unit." Location: PDF page 2, Ordering Information; PDF page 1, description The ordering information prints "406000 29mm Dual Core Transmitter-PLC (no power supply)"; the description prints "The APsmart Rapid Shutdown System Transmitter-PLC is part of a rapid shutdown solution when paired with APsmart RSD, a PV module rapid shutdown unit." Location: PDF page 2, Ordering Information; PDF page 1, description |
| Dimensions | 40 D × 90 W × 35 H mm1.6 D × 3.5 W × 1.4 H in convertedDocumented claim ConditionsPrinted as "Dimensions (W x H x D) 90 mm x 35 mm x 40 mm", width by height by depth. Location: PDF page 2, Structure data, Dimensions (W x H x D) Printed as "Dimensions (W x H x D) 90 mm x 35 mm x 40 mm", width by height by depth. Location: PDF page 2, Structure data, Dimensions (W x H x D) |
| Enclosure | IP30Documented claim ConditionsPrinted as "Enclosure Environmental Rating IP30". Location: PDF page 2, Structure data, Enclosure Environmental Rating Printed as "Enclosure Environmental Rating IP30". Location: PDF page 2, Structure data, Enclosure Environmental Rating |
| Maximum current | 320A (160A*2)Documented claim ConditionsPrinted as "320A (160A*2)" in the 29mm Core column of the core data (the 11mm Core column prints 150A (75A*2)); the datasheet does not explain the "*2". The 406000 ordering line names a 29mm core. Location: PDF page 2, Core data, Max. Current (29mm Core) Printed as "320A (160A*2)" in the 29mm Core column of the core data (the 11mm Core column prints 150A (75A*2)); the datasheet does not explain the "*2". The 406000 ordering line names a 29mm core. Location: PDF page 2, Core data, Max. Current (29mm Core) |
| Maximum system voltage | 1,500 VDocumented claim ConditionsPrinted as "Max. System Voltage 1500VDC". Location: PDF page 2, Core data, Max. System Voltage Printed as "Max. System Voltage 1500VDC". Location: PDF page 2, Core data, Max. System Voltage |
| Operating temperature | -40 to 100 °C-40 to 212 °F convertedDocumented claim ConditionsPrinted as "-40℃~+100℃". Location: PDF page 2, Environmental, Temperature Printed as "-40℃~+100℃". Location: PDF page 2, Environmental, Temperature |
| Rapid shutdown compliance | NEC 2017, 2020 and 2023 (690.12); SunSpecDocumented claim ConditionsPrinted in the features as "Meets NEC 2017, 2020&2023 (690.12) requirements" and "Meets SunSpec requirements". Manufacturer claim; no issuer directory was checked. Location: PDF page 1, features and description Printed in the features as "Meets NEC 2017, 2020&2023 (690.12) requirements" and "Meets SunSpec requirements". Manufacturer claim; no issuer directory was checked. Location: PDF page 1, features and description |
Warranty
Certificate records
No records documented.
Sources and revisions
- APsmart Transmitter-PLC datasheet, North America (Rev3.0, 2026-07-22) (November 2, 2026 capture)Official datasheet · Revision Rev3.0 · Checked https://apsmartglobal.com/wp-content/uploads/2026/07/Transmitter-PLC-datasheet_NA_EN_Rev3.0_2026-07-22.pdf