Charged Reviews
Quick reference
AIMS Power PV-RSD1 Rapid Shutdown Disconnect Switch and Cable Entry Port Set
Model: PV-RSD1 · SKU: PV-RSD1
Prepared Nov 12, 2026
Common specifications
| Device type | Rapid shutdown disconnect switch (RSD) and cable entry port (CEP) setSource [1] |
|---|---|
| Rapid shutdown compliance | Not documented |
| Maximum input power | Not documented |
| Maximum input voltage | Not documented |
| Maximum input current | Not documented |
| Output voltage | Not documented |
| Maximum output current | Not documented |
| Communications | Not documented |
| Efficiency | Not documented |
| Operating temperature | |
| Enclosure | IP65 (cable entry port)Source [1, 2] |
| Safety listing | Not documented |
| Weight | Not documented |
| Dimensions | Not documented |
| Enclosure volume | Not documented |
| Warranty term |
All recorded specifications
| Device type | Rapid shutdown disconnect switch (RSD) and cable entry port (CEP) setDocumented claim ConditionsThe instructions describe a rapid shutdown disconnect switch with a cable entry port that shuts down solar power automatically when no 12 V is present or manually with a push switch. Location: PDF page 1, title and features The instructions describe a rapid shutdown disconnect switch with a cable entry port that shuts down solar power automatically when no 12 V is present or manually with a push switch. Location: PDF page 1, title and features |
|---|---|
| Enclosure | IP65 (cable entry port)Documented claim ConditionsPrinted as a waterproof rating of IP65 for the cable entry port. The store page prints the same value. Location: PDF page 8, specifications, Cable Entry Port (CEP) table Printed as a waterproof rating of IP65 for the cable entry port. The store page prints the same value. Location: PDF page 8, specifications, Cable Entry Port (CEP) table Official instruction manual · Rapid Shutdown Disconnect Switch and Cable Entry Port Instructions, PV-RSD1 (PV-RSD022026) (November 2, 2026 capture)Official product page · AIMS Power product page for the PV-RSD1 (November 2, 2026 capture) [1, 2] |
| Input voltage range | 12 to 160 VDocumented claim ConditionsPrinted as a PV input voltage of 12 to 160 V DC. The store page prints the same range. Location: PDF page 8, specifications, Cable Entry Port (CEP) table Printed as a PV input voltage of 12 to 160 V DC. The store page prints the same range. Location: PDF page 8, specifications, Cable Entry Port (CEP) table Official instruction manual · Rapid Shutdown Disconnect Switch and Cable Entry Port Instructions, PV-RSD1 (PV-RSD022026) (November 2, 2026 capture)Official product page · AIMS Power product page for the PV-RSD1 (November 2, 2026 capture) [1, 2] |
| Maximum current | 40 ADocumented claim ConditionsPrinted as a maximum current of 40A ±5%. The store page prints the same value. Location: PDF page 8, specifications, Cable Entry Port (CEP) table Printed as a maximum current of 40A ±5%. The store page prints the same value. Location: PDF page 8, specifications, Cable Entry Port (CEP) table Official instruction manual · Rapid Shutdown Disconnect Switch and Cable Entry Port Instructions, PV-RSD1 (PV-RSD022026) (November 2, 2026 capture)Official product page · AIMS Power product page for the PV-RSD1 (November 2, 2026 capture) [1, 2] |
| Operating temperature | -40 to 85 °C-40 to 185 °F convertedCalculated(°F - 32) x 5/9: -40 °F = -40 °C, 185 °F = 85 °C ConditionsPrinted as a temperature range of -40 to 185 °F; converted to °C. Location: PDF page 8, specifications, Cable Entry Port (CEP) table Printed as a temperature range of -40 to 185 °F; converted to °C. Location: PDF page 8, specifications, Cable Entry Port (CEP) table |
Warranty
| Warranty term | 2 yearsNeeds confirmationThe PV-RSD1 instructions prints 2 years (shown); the store page prints 3 years. ConditionsPrinted as "2 Year Warranty www.aimscorp.net". A different value is printed elsewhere and kept as an alternative; the primary document value is shown. Location: PDF page 8, specifications Printed as "2 Year Warranty www.aimscorp.net". A different value is printed elsewhere and kept as an alternative; the primary document value is shown. Location: PDF page 8, specifications Official instruction manual · Rapid Shutdown Disconnect Switch and Cable Entry Port Instructions, PV-RSD1 (PV-RSD022026) (November 2, 2026 capture)Official product page · AIMS Power product page for the PV-RSD1 (November 2, 2026 capture) [1, 2] |
|---|
Certificate records
No records documented.
Sources and revisions
- Rapid Shutdown Disconnect Switch and Cable Entry Port Instructions, PV-RSD1 (PV-RSD022026) (November 2, 2026 capture)Official instruction manual · Revision 022026 · Checked https://www.aimscorp.net/wp-content/uploads/2024/03/PV-RSD022026.pdf
- AIMS Power product page for the PV-RSD1 (November 2, 2026 capture)Official product page · Checked https://www.aimscorp.net/product/solar-rapid-shutdown-switch-rsd-cable-entry-port-cep-set/