Victron Energy SmartSolar MPPT RS 450/200-MC4
Model: SmartSolar MPPT RS 450/200-MC4 · SKU: SCC145120512
Prepared Oct 30, 2026
Common specifications
| Controller type | MPPTSource [1] |
|---|---|
| Maximum PV voltage | 450 VSource [1] |
| Maximum PV input power | Not documented |
| Maximum PV input power by battery voltage | Not documented |
| PV input current / MPPT | 16 A per trackerSource [1] |
| Charge current | 200 ASource [1] |
| Battery voltage | 48 VSource [1] |
| Battery chemistry | Not documented |
| Efficiency | Not documented |
| MPPT tracking efficiency | Not documented |
| Maximum conversion efficiency | 96 %Source [1] |
| Full-load efficiency | Not documented |
| Charger efficiency | Not documented |
| Weighted efficiency | Not documented |
| Rated charge power | 11.5 kW at 57.6 VSource [1] |
| Load output current | Not documented |
| Self-consumption | 15 mASource [1] |
| Enclosure | IP21Source [1] |
| Safety listing | EN-IEC 62109-1Source [1] |
| Enclosure volume | 30.86 L** Calculated from recorded external dimensions |
| Warranty term | Not documented |
All recorded specifications
| Battery voltage | 48 VDocumented claim ConditionsPrinted in one cell spanning both columns. Location: Specifications table (PDF page 2), 450|200 column Printed in one cell spanning both columns. Location: Specifications table (PDF page 2), 450|200 column |
|---|---|
| Charge current | 200 ADocumented claim ConditionsPrinted as "Rated charge current 100 A 200 A", one figure per column; 200 A is the 450|200 column. Location: Specifications table (PDF page 2), 450|200 column Printed as "Rated charge current 100 A 200 A", one figure per column; 200 A is the 450|200 column. Location: Specifications table (PDF page 2), 450|200 column |
| Communications | VE.Direct port, VE.Can port & BluetoothDocumented claim ConditionsPrinted in one cell spanning both columns; footnote 6: the MPPT RS is currently not compatible with VE.Smart Networks. Location: Specifications table (PDF page 2), 450|200 column Printed in one cell spanning both columns; footnote 6: the MPPT RS is currently not compatible with VE.Smart Networks. Location: Specifications table (PDF page 2), 450|200 column |
| Controller type | MPPTDocumented claim ConditionsPrinted in the datasheet's description, "Ultra-fast Maximum Power Point Tracking (MPPT) Solar Charge Controller". Location: Datasheet title (PDF page 1) Printed in the datasheet's description, "Ultra-fast Maximum Power Point Tracking (MPPT) Solar Charge Controller". Location: Datasheet title (PDF page 1) |
| Dimensions | 146 D × 434 W × 487 H mm5.75 D × 17.1 W × 19.2 H in convertedDocumented claim ConditionsPrinted as "487 x 434 x 146" under "Dimensions (h x w x d) in mm" for the 450|200 column; the price list prints the same 487 x 434 x 146 (H x W x D) for article SCC145120512. Location: Specifications table (PDF page 2), 450|200 column Printed as "487 x 434 x 146" under "Dimensions (h x w x d) in mm" for the 450|200 column; the price list prints the same 487 x 434 x 146 (H x W x D) for article SCC145120512. Location: Specifications table (PDF page 2), 450|200 column |
| Enclosure | IP21Documented claim ConditionsPrinted in one cell spanning both columns. Location: Specifications table (PDF page 2), 450|200 column Printed in one cell spanning both columns. Location: Specifications table (PDF page 2), 450|200 column |
| Maximum conversion efficiency | 96 %Documented claim ConditionsPrinted in one cell spanning both columns. Location: Specifications table (PDF page 2), 450|200 column Printed in one cell spanning both columns. Location: Specifications table (PDF page 2), 450|200 column |
| Maximum PV voltage | 450 VDocumented claim ConditionsPrinted in one cell spanning both columns. Location: Specifications table (PDF page 2), 450|200 column Printed in one cell spanning both columns. Location: Specifications table (PDF page 2), 450|200 column |
| MPPT trackers | 4Documented claim ConditionsPrinted as "Number of trackers 2 4", one figure per column; 4 is the 450|200 column. Location: Specifications table (PDF page 2), 450|200 column Printed as "Number of trackers 2 4", one figure per column; 4 is the 450|200 column. Location: Specifications table (PDF page 2), 450|200 column |
| MPPT voltage range | 65 - 450 VDocumented claim ConditionsPrinted in one cell spanning both columns as "65 – 450 V" with footnote 1: the range is constrained by battery voltage; PV VOC should not exceed 8 x battery float voltage (for example, a 52.8 V float voltage results in a maximum PV VOC of 422.4 V). Location: Specifications table (PDF page 2), 450|200 column Printed in one cell spanning both columns as "65 – 450 V" with footnote 1: the range is constrained by battery voltage; PV VOC should not exceed 8 x battery float voltage (for example, a 52.8 V float voltage results in a maximum PV VOC of 422.4 V). Location: Specifications table (PDF page 2), 450|200 column |
| Operating temperature | -40 to +60 °C (fan assisted cooling)Documented claim ConditionsPrinted in one cell spanning both columns. Location: Specifications table (PDF page 2), 450|200 column Printed in one cell spanning both columns. Location: Specifications table (PDF page 2), 450|200 column |
| PV input current / MPPT | 16 A per trackerDocumented claim ConditionsPrinted in one cell spanning both columns as the maximum PV operational input current. Location: Specifications table (PDF page 2), 450|200 column Printed in one cell spanning both columns as the maximum PV operational input current. Location: Specifications table (PDF page 2), 450|200 column |
| PV short-circuit current limit | 20 A per trackerDocumented claim ConditionsPrinted in one cell spanning both columns. Footnote 2: a higher short circuit current may damage the controller if the PV array is connected in reverse polarity. Location: Specifications table (PDF page 2), 450|200 column Printed in one cell spanning both columns. Footnote 2: a higher short circuit current may damage the controller if the PV array is connected in reverse polarity. Location: Specifications table (PDF page 2), 450|200 column |
| Rated charge power | 11.5 kW at 57.6 VDocumented claim ConditionsPrinted as "Maximum charge power 5.8 kW at 57.6 V 11.5 kW at 57.6 V", one figure per column; 11.5 kW at 57.6 V is the 450|200 column. This is the charger's output power, not a PV input limit. Location: Specifications table (PDF page 2), 450|200 column Printed as "Maximum charge power 5.8 kW at 57.6 V 11.5 kW at 57.6 V", one figure per column; 11.5 kW at 57.6 V is the 450|200 column. This is the charger's output power, not a PV input limit. Location: Specifications table (PDF page 2), 450|200 column |
| Safety listing | EN-IEC 62109-1Documented claim ConditionsPrinted under Standards, Safety, in one cell spanning both columns: the standard Victron names; no certificate is recorded here. No UL or CSA listing is printed. Location: Specifications table (PDF page 2), 450|200 column Printed under Standards, Safety, in one cell spanning both columns: the standard Victron names; no certificate is recorded here. No UL or CSA listing is printed. Location: Specifications table (PDF page 2), 450|200 column |
| Self-consumption | 15 mADocumented claim ConditionsPrinted in one cell spanning both columns. Location: Specifications table (PDF page 2), 450|200 column Printed in one cell spanning both columns. Location: Specifications table (PDF page 2), 450|200 column |
| Weight | 13.7 kg30.2 lb convertedDocumented claim ConditionsPrinted as "Weight 7.9 kg 13.7 kg", one figure per column; 13.7 kg is the 450|200 column. The price list prints 14 kg for article SCC145120512; the datasheet's figure is recorded. Location: Specifications table (PDF page 2), 450|200 column Printed as "Weight 7.9 kg 13.7 kg", one figure per column; 13.7 kg is the 450|200 column. The price list prints 14 kg for article SCC145120512; the datasheet's figure is recorded. Location: Specifications table (PDF page 2), 450|200 column |
Warranty
Certificate records
No records documented.
Sources and revisions
- SmartSolar MPPT RS 450|100 & 450|200 - Isolated datasheet (September 28, 2026 capture)Official datasheet · Checked Sep 28, 2026https://www.victronenergy.com/upload/documents/Datasheet-SmartSolar-MPPT-RS-EN-.pdf
- Victron Energy price list EUR C, 2026 Q3Official document · Revision 2026-Q3 · Checked Sep 19, 2026https://www.victronenergy.com/media/pricelist/Pricelist_Victron_EUR_C_2026-Q3_Web.pdf