Common specifications
| Controller type | MPPTSource [1, 3] |
|---|---|
| Maximum PV voltage | 250Source [1, 3] |
| Maximum PV input power | 860 W (12 V) / 1720 W (24 V) / 2580 W (36 V) / 3440 W (48 V)Source [1] |
| Maximum PV input power by battery voltage | 860 W at 12 V; 1,720 W at 24 V; 2,580 W at 36 V; 3,440 W at 48 VSource [1] |
| PV input current / MPPT | Not documented |
| Charge current | 60 ASource [1, 3] |
| Battery voltage | 12/24/48 V Auto Select (software tool needed to select 36 V)Source [1] |
| Battery chemistry | Gel long life (OPzV), Gel Exide A600 (OPzV), Gel MK, Gel Victron deep discharge, Gel Exide A200, AGM Victron deep discharge, Stationary tubular plate (OPzS), AGM spiral cell, Rolls AGM, PzS tubular plate traction batteries or OPzS batteries, Lithium Iron Phosphate (LiFePo4) batteriesSource [3] |
| Efficiency | Not documented |
| MPPT tracking efficiency | Not documented |
| Maximum conversion efficiency | 99 %Source [1, 3] |
| Full-load efficiency | Not documented |
| Charger efficiency | Not documented |
| Weighted efficiency | Not documented |
| Rated charge power | Not documented |
| Load output current | Not documented |
| Self-consumption | Less than 35 mA @ 12 V / 20 mA @ 48 VSource [1] |
| Enclosure | IP43 (electronic components), IP22 (connection area)Source [1] |
| Safety listing | EN/IEC 62109-1, UL 1741, CSA C22.2Source [3] |
| Enclosure volume | 4.39 L** Calculated from recorded external dimensions |
| Warranty term | Not documented |
All recorded specifications
| Battery cable size (manual) | 35 mm² / AWG2Documented claim ConditionsPrinted as "Battery terminals 35 mm² / AWG2" in the ENCLOSURE rows of Victron Energy's MPPT solar charger manual SmartSolar MPPT 150/60 up to 250/70 (Rev 12 - 06/2026), one entry for every column; this is the battery terminal size. Section 1.2 (PDF page 6) asks for flexible multi-stranded copper cable. Location: PDF page 72, 9 Technical specifications, ENCLOSURE, Battery terminals row Printed as "Battery terminals 35 mm² / AWG2" in the ENCLOSURE rows of Victron Energy's MPPT solar charger manual SmartSolar MPPT 150/60 up to 250/70 (Rev 12 - 06/2026), one entry for every column; this is the battery terminal size. Section 1.2 (PDF page 6) asks for flexible multi-stranded copper cable. Location: PDF page 72, 9 Technical specifications, ENCLOSURE, Battery terminals row |
|---|---|
| Battery chemistry | Gel long life (OPzV), Gel Exide A600 (OPzV), Gel MK, Gel Victron deep discharge, Gel Exide A200, AGM Victron deep discharge, Stationary tubular plate (OPzS), AGM spiral cell, Rolls AGM, PzS tubular plate traction batteries or OPzS batteries, Lithium Iron Phosphate (LiFePo4) batteriesDocumented claim ConditionsPrinted as "Lithium Iron Phosphate (LiFePo4) batteries" (rotary switch position 7) in Victron Energy's MPPT solar charger manual SmartSolar MPPT 150/60 up to 250/70 (Rev 12 - 06/2026), section 5.1.2; the other names are the suggested battery types printed for positions 0 to 6 of the same table, which applies to every model the manual covers. Listed in the table's order; the app also allows a user defined algorithm. Location: PDF pages 21 and 22, 5.1.2 Settings via the rotary switch, Suggested battery type column Printed as "Lithium Iron Phosphate (LiFePo4) batteries" (rotary switch position 7) in Victron Energy's MPPT solar charger manual SmartSolar MPPT 150/60 up to 250/70 (Rev 12 - 06/2026), section 5.1.2; the other names are the suggested battery types printed for positions 0 to 6 of the same table, which applies to every model the manual covers. Listed in the table's order; the app also allows a user defined algorithm. Location: PDF pages 21 and 22, 5.1.2 Settings via the rotary switch, Suggested battery type column |
| Battery fuse or breaker (manual) | Battery fuse: minimum 70A, maximum 80ADocumented claim ConditionsPrinted as "The battery supply must be protected by a fuse as per the below table." in section 4.2 of Victron Energy's MPPT solar charger manual SmartSolar MPPT 150/60 up to 250/70 (Rev 12 - 06/2026), with the row "MPPT 150/60 and 250/60 70A 80A" under the columns "Minimum battery fuse rating" and "Maximum battery fuse rating". The manual adds "For Canada the battery fuse must comply with the C22.2 standards." Location: PDF page 15, 4.2 Battery, fuse table, MPPT 150/60 and 250/60 row Printed as "The battery supply must be protected by a fuse as per the below table." in section 4.2 of Victron Energy's MPPT solar charger manual SmartSolar MPPT 150/60 up to 250/70 (Rev 12 - 06/2026), with the row "MPPT 150/60 and 250/60 70A 80A" under the columns "Minimum battery fuse rating" and "Maximum battery fuse rating". The manual adds "For Canada the battery fuse must comply with the C22.2 standards." Location: PDF page 15, 4.2 Battery, fuse table, MPPT 150/60 and 250/60 row |
| Battery terminal torque (manual) | 2.4 N·mDocumented claim ConditionsPrinted as "IMPORTANT: Torque the battery and PV connections at 2.4Nm." in section 4.6 of Victron Energy's MPPT solar charger manual SmartSolar MPPT 150/60 up to 250/70 (Rev 12 - 06/2026); one figure for the battery and PV connections, recorded on both the PV and the battery terminal keys. Printed unit spelling "Nm". Location: PDF page 18, 4.6 Electrical connections, IMPORTANT note Printed as "IMPORTANT: Torque the battery and PV connections at 2.4Nm." in section 4.6 of Victron Energy's MPPT solar charger manual SmartSolar MPPT 150/60 up to 250/70 (Rev 12 - 06/2026); one figure for the battery and PV connections, recorded on both the PV and the battery terminal keys. Printed unit spelling "Nm". Location: PDF page 18, 4.6 Electrical connections, IMPORTANT note |
| Battery voltage | 12/24/48 V Auto Select (software tool needed to select 36 V)Documented claim ConditionsPrinted as "Battery voltage 12 / 24 / 48 V Auto Select (software tool needed to select 36 V)", applying to both rated currents, captured September 28, 2026. Location: Specifications table, Battery voltage row Printed as "Battery voltage 12 / 24 / 48 V Auto Select (software tool needed to select 36 V)", applying to both rated currents, captured September 28, 2026. Location: Specifications table, Battery voltage row |
| Charge current | 60 ADocumented claim ConditionsPrinted as "MPPT 250/60 250V 60A 12, 24, 36 and 48V" in the section 2.1 table (PDF page 8) of Victron Energy's MPPT solar charger manual SmartSolar MPPT 150/60 up to 250/70 (Rev 12 - 06/2026), and in this model's column of the Maximum battery current row of chapter 9. Re-cited on 1 October 2026 to the manufacturer's own document; previously cited to Victron Energy (victronenergy.com), which stays listed as an additional source. Location: PDF page 8, 2.1 table of solar chargers covered, this model's row; PDF page 72, 9 Technical specifications, Maximum battery current row Printed as "MPPT 250/60 250V 60A 12, 24, 36 and 48V" in the section 2.1 table (PDF page 8) of Victron Energy's MPPT solar charger manual SmartSolar MPPT 150/60 up to 250/70 (Rev 12 - 06/2026), and in this model's column of the Maximum battery current row of chapter 9. Re-cited on 1 October 2026 to the manufacturer's own document; previously cited to Victron Energy (victronenergy.com), which stays listed as an additional source. Location: PDF page 8, 2.1 table of solar chargers covered, this model's row; PDF page 72, 9 Technical specifications, Maximum battery current row Official installation manual · Victron Energy MPPT solar charger manual SmartSolar MPPT 150/60 up to 250/70 (Rev 12 - 06/2026)Official datasheet · SmartSolar Charge Controllers with screw- or MC4 PV connection MPPT 250/60 & MPPT 250/70 datasheet (September 28, 2026 capture) [1, 3] |
| Communication ports (manual) | VE.Direct socketDocumented claim ConditionsPrinted as "D VE.Direct socket." in the connection overview of Victron Energy's MPPT solar charger manual SmartSolar MPPT 150/60 up to 250/70 (Rev 12 - 06/2026). The same list also names relay screw terminals and remote on/off terminals; Bluetooth is built in. Location: PDF page 17, 4.5 Connection overview, ID Description list Printed as "D VE.Direct socket." in the connection overview of Victron Energy's MPPT solar charger manual SmartSolar MPPT 150/60 up to 250/70 (Rev 12 - 06/2026). The same list also names relay screw terminals and remote on/off terminals; Bluetooth is built in. Location: PDF page 17, 4.5 Connection overview, ID Description list |
| Communications | VE.Direct or BluetoothDocumented claim ConditionsPrinted as "Data communication port VE.Direct or Bluetooth", applying to both rated currents, captured September 28, 2026. Location: Specifications table, Data communication port row Printed as "Data communication port VE.Direct or Bluetooth", applying to both rated currents, captured September 28, 2026. Location: Specifications table, Data communication port row |
| Controller type | MPPTDocumented claim ConditionsPrinted as "MPPT solar charger manual" on the cover of Victron Energy's MPPT solar charger manual SmartSolar MPPT 150/60 up to 250/70 (Rev 12 - 06/2026). Re-cited on 1 October 2026 to the manufacturer's own document; previously cited to Victron Energy (victronenergy.com), which stays listed as an additional source. Location: PDF page 1, cover title Printed as "MPPT solar charger manual" on the cover of Victron Energy's MPPT solar charger manual SmartSolar MPPT 150/60 up to 250/70 (Rev 12 - 06/2026). Re-cited on 1 October 2026 to the manufacturer's own document; previously cited to Victron Energy (victronenergy.com), which stays listed as an additional source. Location: PDF page 1, cover title Official installation manual · Victron Energy MPPT solar charger manual SmartSolar MPPT 150/60 up to 250/70 (Rev 12 - 06/2026)Official datasheet · SmartSolar Charge Controllers with screw- or MC4 PV connection MPPT 250/60 & MPPT 250/70 datasheet (September 28, 2026 capture) [1, 3] |
| Dimensions | 95 D × 250 W × 185 H mm3.7 D × 9.84 W × 7.28 H in convertedDocumented claim ConditionsPrinted as "Tr models: 185 x 250 x 95 mm" in Victron Energy's MPPT solar charger manual SmartSolar MPPT 150/60 up to 250/70 (Rev 12 - 06/2026); the recorded text is the Tr or MC4 entry for this model's column. Re-cited on 1 October 2026 to the manufacturer's own document; previously cited to Victron Energy (victronenergy.com), which stays listed as an additional source. The document labels the row "Dimensions (h x w x d)" and prints "185 x 250 x 95 mm" for this model. Revised on 13 October 2026: stored as text before; converted to numbers using the axis order the document prints (height x width x depth). Location: PDF page 72, 9 Technical specifications, Dimensions (h x w x d) row Printed as "Tr models: 185 x 250 x 95 mm" in Victron Energy's MPPT solar charger manual SmartSolar MPPT 150/60 up to 250/70 (Rev 12 - 06/2026); the recorded text is the Tr or MC4 entry for this model's column. Re-cited on 1 October 2026 to the manufacturer's own document; previously cited to Victron Energy (victronenergy.com), which stays listed as an additional source. The document labels the row "Dimensions (h x w x d)" and prints "185 x 250 x 95 mm" for this model. Revised on 13 October 2026: stored as text before; converted to numbers using the axis order the document prints (height x width x depth). Location: PDF page 72, 9 Technical specifications, Dimensions (h x w x d) row Official installation manual · Victron Energy MPPT solar charger manual SmartSolar MPPT 150/60 up to 250/70 (Rev 12 - 06/2026)Official datasheet · SmartSolar Charge Controllers with screw- or MC4 PV connection MPPT 250/60 & MPPT 250/70 datasheet (September 28, 2026 capture) [1, 3] |
| Enclosure | IP43 (electronic components), IP22 (connection area)Documented claim ConditionsPrinted as "Protection category IP43 (electronic components), IP22 (connection area)", applying to both rated currents, captured September 28, 2026. Location: Specifications table, Protection category row Printed as "Protection category IP43 (electronic components), IP22 (connection area)", applying to both rated currents, captured September 28, 2026. Location: Specifications table, Protection category row |
| Grounding (manual) | The solar charger can be installed in a positive or in a negative grounded system.; Apply a single ground connection, preferably close to the battery, to prevent system issues or ground loops.; The positive and negative of the PV array should not be grounded.; This charge controller must be used with an external GFDI device as required by the Article 690 of the USA National Electrical Code for the installation location.Documented claim ConditionsPrinted as "The solar charger can be installed in a positive or in a negative grounded system." in section 4.4 of Victron Energy's MPPT solar charger manual SmartSolar MPPT 150/60 up to 250/70 (Rev 12 - 06/2026), which also prints the other quoted sentences on PV array grounding and ground fault detection. The connection overview names a ground screw. Location: PDF page 17, 4.4 Grounding Printed as "The solar charger can be installed in a positive or in a negative grounded system." in section 4.4 of Victron Energy's MPPT solar charger manual SmartSolar MPPT 150/60 up to 250/70 (Rev 12 - 06/2026), which also prints the other quoted sentences on PV array grounding and ground fault detection. The connection overview names a ground screw. Location: PDF page 17, 4.4 Grounding |
| Installation clearances (manual) | Minimum clearance of 10cm under and above the solar chargerDocumented claim ConditionsPrinted as "Observe a minimum clearance of 10cm under and above the solar charger for optimal cooling." in section 4.1 of Victron Energy's MPPT solar charger manual SmartSolar MPPT 150/60 up to 250/70 (Rev 12 - 06/2026). Location: PDF page 15, 4.1 Mounting Printed as "Observe a minimum clearance of 10cm under and above the solar charger for optimal cooling." in section 4.1 of Victron Energy's MPPT solar charger manual SmartSolar MPPT 150/60 up to 250/70 (Rev 12 - 06/2026). Location: PDF page 15, 4.1 Mounting |
| Maximum conversion efficiency | 99 %Documented claim ConditionsPrinted as "Peak efficiency 99%" in Victron Energy's MPPT solar charger manual SmartSolar MPPT 150/60 up to 250/70 (Rev 12 - 06/2026), one entry for every column of the table. Re-cited on 1 October 2026 to the manufacturer's own document; previously cited to Victron Energy (victronenergy.com), which stays listed as an additional source. Location: PDF page 72, 9 Technical specifications, Peak efficiency row Printed as "Peak efficiency 99%" in Victron Energy's MPPT solar charger manual SmartSolar MPPT 150/60 up to 250/70 (Rev 12 - 06/2026), one entry for every column of the table. Re-cited on 1 October 2026 to the manufacturer's own document; previously cited to Victron Energy (victronenergy.com), which stays listed as an additional source. Location: PDF page 72, 9 Technical specifications, Peak efficiency row Official installation manual · Victron Energy MPPT solar charger manual SmartSolar MPPT 150/60 up to 250/70 (Rev 12 - 06/2026)Official datasheet · SmartSolar Charge Controllers with screw- or MC4 PV connection MPPT 250/60 & MPPT 250/70 datasheet (September 28, 2026 capture) [1, 3] |
| Maximum PV input power | 860 W (12 V) / 1720 W (24 V) / 2580 W (36 V) / 3440 W (48 V)Documented claim ConditionsPrinted as this model's own Nominal PV power figures at each supported battery voltage, captured September 28, 2026. Location: Specifications table, Nominal PV power rows Printed as this model's own Nominal PV power figures at each supported battery voltage, captured September 28, 2026. Location: Specifications table, Nominal PV power rows |
| Maximum PV input power by battery voltage | 860 W at 12 V; 1,720 W at 24 V; 2,580 W at 36 V; 3,440 W at 48 VDocumented claim ConditionsPrinted in the "Nominal PV power" rows of Victron Energy's SmartSolar MPPT 250/60 and 250/70 datasheet, this model's column: 860 W at 12 V / 1720 W at 24 V / 2580 W at 36 V / 3440 W at 48 V. Footnote 1a) of the same table: "If more PV power is connected, the controller will limit input power." The controller limits its input to this figure, so it is the maximum PV input power the controller uses. Manufacturer claim, captured September 28, 2026. Location: Specifications table, Nominal PV power rows, this model's column Printed in the "Nominal PV power" rows of Victron Energy's SmartSolar MPPT 250/60 and 250/70 datasheet, this model's column: 860 W at 12 V / 1720 W at 24 V / 2580 W at 36 V / 3440 W at 48 V. Footnote 1a) of the same table: "If more PV power is connected, the controller will limit input power." The controller limits its input to this figure, so it is the maximum PV input power the controller uses. Manufacturer claim, captured September 28, 2026. Location: Specifications table, Nominal PV power rows, this model's column |
| Maximum PV voltage | 250Documented claim ConditionsPrinted as "250V absolute maximum coldest conditions 245V start-up and operating maximum" in Victron Energy's MPPT solar charger manual SmartSolar MPPT 150/60 up to 250/70 (Rev 12 - 06/2026); the 245 V start-up and operating maximum is printed beside it. Re-cited on 1 October 2026 to the manufacturer's own document; previously cited to Victron Energy (victronenergy.com), which stays listed as an additional source. Location: PDF page 72, 9 Technical specifications, Maximum PV open circuit voltage row Printed as "250V absolute maximum coldest conditions 245V start-up and operating maximum" in Victron Energy's MPPT solar charger manual SmartSolar MPPT 150/60 up to 250/70 (Rev 12 - 06/2026); the 245 V start-up and operating maximum is printed beside it. Re-cited on 1 October 2026 to the manufacturer's own document; previously cited to Victron Energy (victronenergy.com), which stays listed as an additional source. Location: PDF page 72, 9 Technical specifications, Maximum PV open circuit voltage row Official installation manual · Victron Energy MPPT solar charger manual SmartSolar MPPT 150/60 up to 250/70 (Rev 12 - 06/2026)Official datasheet · SmartSolar Charge Controllers with screw- or MC4 PV connection MPPT 250/60 & MPPT 250/70 datasheet (September 28, 2026 capture) [1, 3] |
| Mounting orientation (manual) | Vertically on a non-flammable substrate, with the electrical terminals facing downwardsDocumented claim ConditionsPrinted as "Mount the solar charger vertically on a non-flammable substrate, with the electrical terminals facing downwards." in section 4.1 of Victron Energy's MPPT solar charger manual SmartSolar MPPT 150/60 up to 250/70 (Rev 12 - 06/2026). The same section adds "Mount the solar charger within 3 meters from the battery, but never directly above the battery." Location: PDF page 15, 4.1 Mounting Printed as "Mount the solar charger vertically on a non-flammable substrate, with the electrical terminals facing downwards." in section 4.1 of Victron Energy's MPPT solar charger manual SmartSolar MPPT 150/60 up to 250/70 (Rev 12 - 06/2026). The same section adds "Mount the solar charger within 3 meters from the battery, but never directly above the battery." Location: PDF page 15, 4.1 Mounting |
| Operating temperature | -30 to +60 °C (full rated output up to 40 °C)Documented claim ConditionsPrinted as "Operating temperature -30 to +60 °C (full rated output up to 40 °C)", applying to both rated currents, captured September 28, 2026. Location: Specifications table, Operating temperature row Printed as "Operating temperature -30 to +60 °C (full rated output up to 40 °C)", applying to both rated currents, captured September 28, 2026. Location: Specifications table, Operating temperature row |
| PV conductors (manual) | Tr models: 35 mm² / AWG2Documented claim ConditionsPrinted as "PV terminals Tr models: 35 mm² / AWG2" in the ENCLOSURE rows of Victron Energy's MPPT solar charger manual SmartSolar MPPT 150/60 up to 250/70 (Rev 12 - 06/2026); this model is a Tr (screw terminal) model, and the figure is the PV terminal size. Location: PDF page 72, 9 Technical specifications, ENCLOSURE, PV terminals row Printed as "PV terminals Tr models: 35 mm² / AWG2" in the ENCLOSURE rows of Victron Energy's MPPT solar charger manual SmartSolar MPPT 150/60 up to 250/70 (Rev 12 - 06/2026); this model is a Tr (screw terminal) model, and the figure is the PV terminal size. Location: PDF page 72, 9 Technical specifications, ENCLOSURE, PV terminals row |
| PV disconnect (manual) | Provide a means to disconnect all current-carrying conductors of a photo-voltaic power source from all other conductors in a building or other structure.Documented claim ConditionsPrinted as "Provide a means to disconnect all current-carrying conductors of a photo-voltaic power source from all other conductors in a building or other structure." in section 4.3 of Victron Energy's MPPT solar charger manual SmartSolar MPPT 150/60 up to 250/70 (Rev 12 - 06/2026). No rating for the disconnect is printed. Location: PDF page 16, 4.3 PV array Printed as "Provide a means to disconnect all current-carrying conductors of a photo-voltaic power source from all other conductors in a building or other structure." in section 4.3 of Victron Energy's MPPT solar charger manual SmartSolar MPPT 150/60 up to 250/70 (Rev 12 - 06/2026). No rating for the disconnect is printed. Location: PDF page 16, 4.3 PV array |
| PV terminal torque (manual) | 2.4 N·mDocumented claim ConditionsPrinted as "IMPORTANT: Torque the battery and PV connections at 2.4Nm." in section 4.6 of Victron Energy's MPPT solar charger manual SmartSolar MPPT 150/60 up to 250/70 (Rev 12 - 06/2026); one figure for the battery and PV connections, recorded on both the PV and the battery terminal keys. Printed unit spelling "Nm". Location: PDF page 18, 4.6 Electrical connections, IMPORTANT note Printed as "IMPORTANT: Torque the battery and PV connections at 2.4Nm." in section 4.6 of Victron Energy's MPPT solar charger manual SmartSolar MPPT 150/60 up to 250/70 (Rev 12 - 06/2026); one figure for the battery and PV connections, recorded on both the PV and the battery terminal keys. Printed unit spelling "Nm". Location: PDF page 18, 4.6 Electrical connections, IMPORTANT note |
| Safety listing | EN/IEC 62109-1, UL 1741, CSA C22.2Documented claim ConditionsPrinted as "Safety EN/IEC 62109-1, UL 1741, CSA C22.2" in the STANDARDS rows of Victron Energy's MPPT solar charger manual SmartSolar MPPT 150/60 up to 250/70 (Rev 12 - 06/2026), one entry for every column of the table. Manufacturer claim as printed. Location: PDF page 72, 9 Technical specifications, STANDARDS, Safety row Printed as "Safety EN/IEC 62109-1, UL 1741, CSA C22.2" in the STANDARDS rows of Victron Energy's MPPT solar charger manual SmartSolar MPPT 150/60 up to 250/70 (Rev 12 - 06/2026), one entry for every column of the table. Manufacturer claim as printed. Location: PDF page 72, 9 Technical specifications, STANDARDS, Safety row |
| Self-consumption | Less than 35 mA @ 12 V / 20 mA @ 48 VDocumented claim ConditionsPrinted as "Self-consumption Less than 35 mA @ 12 V / 20 mA @ 48 V", applying to both rated currents, captured September 28, 2026. Location: Specifications table, Self-consumption row Printed as "Self-consumption Less than 35 mA @ 12 V / 20 mA @ 48 V", applying to both rated currents, captured September 28, 2026. Location: Specifications table, Self-consumption row |
| Weight | 3 kg6.6 lb convertedDocumented claim ConditionsPrinted as "Weight 3 kg" in Victron Energy's MPPT solar charger manual SmartSolar MPPT 150/60 up to 250/70 (Rev 12 - 06/2026), read for this model's column. Re-cited on 1 October 2026 to the manufacturer's own document; previously cited to Victron Energy (victronenergy.com), which stays listed as an additional source. Location: PDF page 72, 9 Technical specifications, Weight row Printed as "Weight 3 kg" in Victron Energy's MPPT solar charger manual SmartSolar MPPT 150/60 up to 250/70 (Rev 12 - 06/2026), read for this model's column. Re-cited on 1 October 2026 to the manufacturer's own document; previously cited to Victron Energy (victronenergy.com), which stays listed as an additional source. Location: PDF page 72, 9 Technical specifications, Weight row Official installation manual · Victron Energy MPPT solar charger manual SmartSolar MPPT 150/60 up to 250/70 (Rev 12 - 06/2026)Official datasheet · SmartSolar Charge Controllers with screw- or MC4 PV connection MPPT 250/60 & MPPT 250/70 datasheet (September 28, 2026 capture) [1, 3] |
Warranty
Certificate records
| EN/IEC 62109-1 | Claimed · Listed when checkedApplies to: unresolved document set Victron Energy's own range datasheet prints "Safety EN/IEC 62109-1, UL 1741, CSA C22.2" under STANDARDS for this model family, captured September 28, 2026. Recorded as printed: no certificate number or issuing body file number is given, so it is a manufacturer claim and not issuer-verified. [1] |
|---|---|
| UL 1741 | Claimed · Listed when checkedApplies to: unresolved document set Victron Energy's own range datasheet prints "Safety EN/IEC 62109-1, UL 1741, CSA C22.2" under STANDARDS for this model family, captured September 28, 2026. Recorded as printed: no certificate number or issuing body file number is given, so it is a manufacturer claim and not issuer-verified. [1] |
| CSA C22.2 | Claimed · Listed when checkedApplies to: unresolved document set Victron Energy's own range datasheet prints "Safety EN/IEC 62109-1, UL 1741, CSA C22.2" under STANDARDS for this model family, captured September 28, 2026. Recorded as printed: no certificate number or issuing body file number is given, so it is a manufacturer claim and not issuer-verified. [1] |
Sources and revisions
- SmartSolar Charge Controllers with screw- or MC4 PV connection MPPT 250/60 & MPPT 250/70 datasheet (September 28, 2026 capture)Official datasheet · Checked Sep 28, 2026https://www.victronenergy.com/upload/documents/Datasheet-SmartSolar-charge-controller-MPPT-250-60-and-250-70-EN.pdf
- SmartSolar MPPT 150/60 up to 250/70 product page (September 28, 2026 capture)Official product page · Checked Sep 28, 2026https://www.victronenergy.com/solar-charge-controllers/smartsolar-250-85-250-100
- Victron Energy MPPT solar charger manual SmartSolar MPPT 150/60 up to 250/70 (Rev 12 - 06/2026)Official installation manual · Revision Rev 12 · 2026-06 · Checked Oct 1, 2026https://www.victronenergy.com/upload/documents/Manual_SmartSolar_MPPT_150-60_up_to_250-70/29694-MPPT_solar_charger_manual-pdf-en.pdf