Common specifications
| Controller type | MPPTSource [2] |
|---|---|
| Maximum PV voltage | 150 VSource [2] |
| Maximum PV input power | 750 W at 12 V; 1500 W at 24 V; 3000 W at 48 V; 3750 W at 60 VSource [2] |
| Maximum PV input power by battery voltage | Not documented |
| PV input current / MPPT | Not documented |
| Charge current | 60 ASource [1] |
| Battery voltage | 12, 24, 36, 48 or 60 VDC (single model, selectable)Source [2] |
| Battery chemistry | Not documented |
| Efficiency | Not documented |
| MPPT tracking efficiency | Not documented |
| Maximum conversion efficiency | 98.1 %Source [2] |
| Full-load efficiency | Not documented |
| Charger efficiency | Not documented |
| Weighted efficiency | Not documented |
| Rated charge power | Not documented |
| Load output current | Not documented |
| Self-consumption | Not documented |
| Enclosure | Indoor Type 1Source [2] |
| Safety listing | Not documented |
| Enclosure volume | Not documented |
| Warranty term | 5 yearsSource [2] |
All recorded specifications
| Battery voltage | 12, 24, 36, 48 or 60 VDC (single model, selectable)Documented claim ConditionsPrinted as one model, selectable at start-up. Location: PDF page 2, FLEXmax 60/80 Specifications, FLEXmax 60 column Printed as one model, selectable at start-up. Location: PDF page 2, FLEXmax 60/80 Specifications, FLEXmax 60 column |
|---|---|
| Charge current | 60 ADocumented claim ConditionsPrinted as 60 amps maximum continuous output current (up to 40°C without thermal derating) in the owner's manual; the 2019 spec sheet prints 60A @ 104°F (40°C) with adjustable current limit. Location: PDF page 7, Introduction, features Printed as 60 amps maximum continuous output current (up to 40°C without thermal derating) in the owner's manual; the 2019 spec sheet prints 60A @ 104°F (40°C) with adjustable current limit. Location: PDF page 7, Introduction, features |
| Controller type | MPPTDocumented claim ConditionsPrinted as continuous MPPT. Location: PDF page 1, Page 1, title Printed as continuous MPPT. Location: PDF page 1, Page 1, title |
| Enclosure | Indoor Type 1Documented claim ConditionsPrinted as Indoor Type 1. Location: PDF page 2, FLEXmax 60/80 Specifications, FLEXmax 60 column Printed as Indoor Type 1. Location: PDF page 2, FLEXmax 60/80 Specifications, FLEXmax 60 column |
| Maximum conversion efficiency | 98.1 %Documented claim ConditionsPrinted as power conversion efficiency, typical. Location: PDF page 2, FLEXmax 60/80 Specifications, FLEXmax 60 column Printed as power conversion efficiency, typical. Location: PDF page 2, FLEXmax 60/80 Specifications, FLEXmax 60 column |
| Maximum PV input power | 750 W at 12 V; 1500 W at 24 V; 3000 W at 48 V; 3750 W at 60 VDocumented claim ConditionsPrinted as the NEC recommended solar array STC nameplate per battery voltage. Location: PDF page 2, FLEXmax 60/80 Specifications, FLEXmax 60 column Printed as the NEC recommended solar array STC nameplate per battery voltage. Location: PDF page 2, FLEXmax 60/80 Specifications, FLEXmax 60 column |
| Maximum PV voltage | 150 VDocumented claim ConditionsPrinted as 150VDC absolute maximum at the coldest conditions (145VDC start-up and operating maximum). Location: PDF page 2, FLEXmax 60/80 Specifications, FLEXmax 60 column Printed as 150VDC absolute maximum at the coldest conditions (145VDC start-up and operating maximum). Location: PDF page 2, FLEXmax 60/80 Specifications, FLEXmax 60 column |
| Operating temperature | -40 to 60 °C-40 to 140 °F convertedDocumented claim ConditionsPrinted as –40 to 60°C, power derated above 40°C. Location: PDF page 2, FLEXmax 60/80 Specifications, FLEXmax 60 column Printed as –40 to 60°C, power derated above 40°C. Location: PDF page 2, FLEXmax 60/80 Specifications, FLEXmax 60 column |
Warranty
| Warranty term | 5 yearsDocumented claim ConditionsPrinted as standard 5 year, extended 10 year available. Location: PDF page 2, FLEXmax 60/80 Specifications, FLEXmax 60 column Printed as standard 5 year, extended 10 year available. Location: PDF page 2, FLEXmax 60/80 Specifications, FLEXmax 60 column |
|---|
Certificate records
No records documented.
Sources and revisions
- OutBack Power FLEXmax Series Charge Controllers (FLEXmax 80) Owner's Manual (900-0009-01-00 Rev D)Official installation manual · Revision Rev D · 2020-01 · Checked https://outbackpower.com/wp-content/uploads/2026/06/owner_manual.pdf
- FLEXmax 60/80 Specifications, #980-00080-01-001 REV A, 09/2019 (OutBack Power)Official datasheet · Revision #980-00080-01-001 REV A · Checked https://outbackpower.com/downloads/documents/charge_controllers/flexmax_6080/specsheet.pdf