Charged ReviewsSaved 0Compare 0Login

Charged Reviews

Quick reference

Morningstar TriStar MPPT 60A Solar Controller

Model: TS-MPPT-60 · SKU: TS-MPPT-60

Prepared

Common specifications

FieldValueSources
Controller typeMPPT[1]
Max PV voltage150 V[2] [1]
Max PV input power3,200 W[1]
Max PV input power12: 1,100, 24: 2,100, 48: 4,200 W[1]
Max PV current?
Charge current60 A[2] [1]
Battery voltage12, 24, or 48 volts DC[1]
Supported chemistrySealed; AGM/Flooded; Flooded; Custom[2]
Efficiency99 %[1]
MPPT tracking efficiency?
Max conversion efficiency?
Full load efficiency?
Charger efficiency?
Weighted efficiency?
Rated charge powerNominal Maximum Output Power: 800 Watts (12 Volt); 1600 Watts (24 Volt); 3200 Watts (48 Volt)[2]
Load output?
Self consumption1.3 - 2.7 Watts[2]
Enclosure ratingType 1 (indoor and vented), IP20[1]
ListingEN60335-1 and EN60335-2-29 (battery chargers)[2]
Warranty term5 years[1]

All recorded specifications

FieldValueSources
ListingEN60335-1 and EN60335-2-29 (battery chargers)[2]
GroundingUse a copper wire to connect the grounding terminal in the wiring box to earth ground.; Do not connect the system negative conductor to this terminal.[2]
Weight4.14 kg Needs confirmation[2]
PV wire size2.5 mm2 / #14 AWG minimum; 33.6 mm2 / #2 AWG maximum[2]
Clearancesat least 6” (150 mm) above and below and at least 1” (25 mm) on each side[2]
Dimensions29.1 × 13.0 × 14.2 cm[1]
PV disconnect80 Amps[2]
CommunicationsMeterBus, RS-232, EIA-485 (60A models), Ethernet (60A models), EMC-1[1]
Efficiency99 %[1]
Controller typeMPPT[1]
Charge current60 A[2] [1]
Enclosure ratingType 1 (indoor and vented), IP20[1]
Ground wire size8 AWG (8 mm2)[2]
Max PV voltage150 V[2] [1]
Battery voltage12, 24, or 48 volts DC[1]
Battery wire size#4 AWG at 30ºC, #3 AWG above 40°C (raceway, cable, or earth); #6 AWG (free air); 16 - 25 mm2[2]
Battery protection75 or 80 Amps[2]
Max PV input power3,200 W[1]
PV terminal torque50 in-lb[2]
Rated charge powerNominal Maximum Output Power: 800 Watts (12 Volt); 1600 Watts (24 Volt); 3200 Watts (48 Volt)[2]
Self consumption1.3 - 2.7 Watts[2]
Communication portsMeterBus port (RJ-11); Ethernet port (RJ-45); Serial RS-232 port (DB-9); EIA-485 port (four position screw terminal)[2]
Supported chemistrySealed; AGM/Flooded; Flooded; Custom[2]
Max PV input power12: 1,100, 24: 2,100, 48: 4,200 W[1]
Mounting orientationVertical surface[2]
Battery terminal torque50 in-lb[2]
Battery voltage range8 - 72 Volts dc[2]
Operating temperature-40 °C to +45 °C Needs confirmation[2]

Warranty

FieldValueSources
Warranty term5 years[1]

Certificate records

StandardRecordEvidenceSources
UL 1741Claimed · present at observation[1]
CSA C22.2 No. 107.1-01Claimed · present at observation[1]
FCC Class B Part 15Claimed · present at observation[1]
IEC 62109-1Claimed · present at observation[1]

Sources and revisions

  1. Morningstar's own TriStar MPPT datasheet, control #MS-001901, revision 2/2025, from morningstarcorp.com's own TriStar MPPT product page. Manufacturer datasheet (PDF) · Checked Sep 27, 2026 https://www.morningstarcorp.com/wp-content/uploads/datasheet-tristar-mppt-en.pdf
  2. Morningstar TriStar MPPT Solar Charging System Controller Installation, Operation and Maintenance Manual (MS-000946 v7.2) Installation manual · Revision MS-000946 v7.2 · Checked Oct 1, 2026 https://www.morningstarcorp.com/wp-content/uploads/operation-manual-tristar-mppt-en.pdf