Key specs

Charge current45 A
Weight1.6 kg
Max PV voltage125 V
Load output45 A

All specifications

Identity

BrandMorningstar · Website
ModelTS-45
MarketUnknown
Manufacturer SKUTS-45
About brandMorningstar Corporation, based in Newtown, Pennsylvania since 1993, makes solar charge controllers and inverters used in off-grid, industrial and hazardous-location power systems worldwide; its datasheets describe the company as employee-owned with well over three million products made.
SKU detail
locator: Versions line
conditions: Printed as this model's own version, no meter (the meter-equipped version in this line, TS-60M, is a 60A model built as a separate record).
Sources: [1]
FieldValueConditionsSource
GroundingUse the grounding terminal in the wiring compartment to connect a copper wire to an earth ground or similar grounding point.
Printed as "Use the grounding terminal in the wiring compartment to connect a copper wire to an earth ground or similar grounding point." in Morningstar's TriStar Installation, Operation and Maintenance Manual (MS-001156 v4.7), Step 6 Ground Connection, for all TriStar models. The TriStar negative terminals are common negative.
Where: PDF page 15, section 2.3, Step 6, Ground Connection
[2]
Weight1.6 kgPrinted as a single value shared across both models.
Where: Mechanical block, Weight row
[1]
PV wire size16 mm2 (6 AWG) with 75C wire; 10 mm2 (8 AWG) with 90C wire (ambient to 45C)
Printed as "TS-45 75C Wire 90C Wire TS-60 75C Wire 90C Wire" in Morningstar's TriStar Installation, Operation and Maintenance Manual (MS-001156 v4.7), Table 2.3-6b, the TS-45 columns (75C wire, 90C wire) for ambient temperatures to 45C. The table applies to the wires carrying the system current. The power terminals are sized for 35 - 2.5 mm2 (2-14 AWG) wire (PDF page 14).
Where: PDF page 15, section 2.3, Step 6, Table 2.3-6b (Minimum Wire Size)
[2]
Clearancesopen space above and below the heat sink, and at least 75 mm (3 inches) clearance around the heat sink
Printed as "There should be open space above and below the heat sink, and at least 75 mm (3 inches) clearance around the heat sink to allow free air flow for cooling." in Morningstar's TriStar Installation, Operation and Maintenance Manual (MS-001156 v4.7), section 2.3, Step 2, for all TriStar models.
Where: PDF page 10, section 2.3, Step 2 (Mounting)
[2]
DimensionsW 127 × H 260 × D 71 mm / W 5 × H 10.3 × D 2.8 in
Printed as a single value shared across both models (height, width, depth). Printed as "Dimensions Height: 26.0cm/10.3 in Width: 12.7cm/5.0 in Depth: 7.1cm/2.8 in" in Morningstar's TriStar datasheet. Revised on 13 October 2026: stored as text before; converted to numbers using the axis order the document prints (height x width x depth).
Where: Mechanical block, Dimensions row
Sources
Converted: 26 x 12.7 x 7.1 cm x 10 mm/cm
[1]
Load output45 A
Printed as this model's own rated current, which the datasheet states applies equally to charge, load or diversion control.
Where: Electrical block, Rated solar, load or diversion current row
[1]
PV disconnectmaximum of 70 amps
Printed as "must be a maximum of 70 amps for the TriStar-PWM-45, and 90 amps for the TriStar-PWM-60/M" in Morningstar's TriStar Installation, Operation and Maintenance Manual (MS-001156 v4.7), section 2.1, which says solar and battery fuses or DC breakers are required and gives the maximum for the TriStar-PWM-45. Section 2.3 (PDF page 15) says the NEC requires manually operated disconnect switches or circuit breakers between the TriStar and the battery.
Where: PDF page 9, section 2.1 (General Information), warning on fuses and DC breakers
[2]
CommunicationsRS-232Printed describing the controller's communication capability.
Where: Key Features and Benefits
[1]
Controller typePWM
Printed in the datasheet's own product name, describing the pulse-width-modulation regulation the controller uses for charge control.
Where: Title
[1]
Charge current45 A
Printed as this model's own rated current.
Where: Electrical block, Rated solar, load or diversion current row
[1]
Enclosure ratingType 1, indoor rated, IP20Printed as a single value shared across both models.
Where: Mechanical block, Enclosure row
[1]
Ground wire size10 AWG (5 mm2)
Printed as "TS-45 10 AWG (5 mm2)" in Morningstar's TriStar Installation, Operation and Maintenance Manual (MS-001156 v4.7), Step 6 Ground Connection, the minimum copper grounding wire size printed for the TS-45. Or a wire of the same or greater cross-sectional area as the PV wires.
Where: PDF page 15, section 2.3, Step 6, Ground Connection
[2]
Max PV voltage125 V
Printed as "Never exceed a Voc (open-circuit voltage) of 125V." in Morningstar's TriStar Installation, Operation and Maintenance Manual (MS-001156 v4.7), the section 2.3 safety notes, for all TriStar models. Re-cited on 1 October 2026 to the manufacturer's own document; previously cited to Morningstar (morningstarcorp.com), which stays listed as an additional source.
Where: PDF page 10, section 2.3 (Installation Steps), safety notes
[2] [1]
Battery voltage12, 24, 48VPrinted as a single value shared across both models.
Where: Electrical block, System Voltage row
[1]
Battery wire size16 mm2 (6 AWG) with 75C wire; 10 mm2 (8 AWG) with 90C wire (ambient to 45C)
Printed as "TS-45 75C Wire 90C Wire TS-60 75C Wire 90C Wire" in Morningstar's TriStar Installation, Operation and Maintenance Manual (MS-001156 v4.7), Table 2.3-6b, the TS-45 columns (75C wire, 90C wire) for ambient temperatures to 45C. The minimum copper wire the NEC allows for the system current; aluminum must be one size larger. The power terminals are sized for 35 - 2.5 mm2 (2-14 AWG) wire.
Where: PDF page 15, section 2.3, Step 6, Table 2.3-6b (Minimum Wire Size)
[2]
Battery protectionmaximum of 70 amps
Printed as "must be a maximum of 70 amps for the TriStar-PWM-45, and 90 amps for the TriStar-PWM-60/M" in Morningstar's TriStar Installation, Operation and Maintenance Manual (MS-001156 v4.7), section 2.1, which says solar and battery fuses or DC breakers are required and gives the maximum for the TriStar-PWM-45. Breakers and fuses may require lower ratings so as not to exceed a wire's ampacity.
Where: PDF page 9, section 2.1 (General Information), warning on fuses and DC breakers
[2]
PV terminal torque5.65 N·m
Printed as "Torque terminals 5.65 Nm / 50 in-lb" in Morningstar's TriStar Installation, Operation and Maintenance Manual (MS-001156 v4.7), the Technical Specifications Mechanical list, printed once for all TriStar models; the printed spelling is "Nm".
Where: PDF page 33, Technical Specifications, Mechanical, Torque terminals row
[2]
Self consumption ma20 mA
Printed as the controller's own maximum self-consumption, shared across both models; the datasheet separately prints 7.5mA for the optional meter.
Where: Electrical block, Self-consumption row
[1]
Supported chemistrylead-acid (12, 24 or 48 volt) with the standard battery charging programs
Printed as "Charge only 12, 24, or 48 volt lead-acid batteries when using the standard battery charging programs in the TriStar." in Morningstar's TriStar Installation, Operation and Maintenance Manual (MS-001156 v4.7), section 2.3 safety notes, for all TriStar models.
Where: PDF page 10, section 2.3 (Installation Steps), safety notes
[2]
Battery terminal torque5.65 N·m
Printed as "Torque terminals 5.65 Nm / 50 in-lb" in Morningstar's TriStar Installation, Operation and Maintenance Manual (MS-001156 v4.7), the Technical Specifications Mechanical list, printed once for all TriStar models; the printed spelling is "Nm".
Where: PDF page 33, Technical Specifications, Mechanical, Torque terminals row
[2]
Operating temperature–40 to +45ºC Check note
The manual and the data sheet print different operating temperature ranges. Morningstar's TriStar Operator's Manual (MS-001156 v4.7) prints an ambient temperature range of –40 to +45ºC; Morningstar's TriStar data sheet prints -40°C to +60°C.
Printed as "Ambient temperature –40 to +45ºC" in Morningstar's TriStar Installation, Operation and Maintenance Manual (MS-001156 v4.7), the Technical Specifications Environmental list, printed once for all TriStar models. Revised on 1 October 2026: The installation and operation manual is the primary source; it prints an ambient temperature range of –40 to +45ºC, while the data sheet prints -40°C to +60°C.
Where: PDF page 33, Technical Specifications, Environmental, Ambient temperature row
Sources
-40°C to +60°C

Printed as a single value shared across both models; both may derate above 55°C.

[1]
[2]

Owner reviews

No owner reviews yet
Write a review

Sellers

No listed sellers in this data.

Price history

No seller price history.

Quick reference sheet

Controller type
PWM
Maximum PV voltage (Voc)
125 V
Rated charge current
45 A
Battery voltages
12, 24, 48V
Maximum PV input power
Not stated
Peak efficiency
Not stated

Evidence score

This category has no Evidence score.

Certificates

What this shows: what each record says and how far it reaches. It does not mean the product is approved.
UL 1741manufacturer claimpresent at observation[1]
Scope
equipment listing
Covered models
tristar-45
Limitations
Printed in the manufacturer's own datasheet Certifications block, captured September 28, 2026; no certificate number or issuer file number is given, so it is a manufacturer claim and not issuer-verified.
Record detail
Issued: Not stated
Valid from: Not stated
Expiry: Not stated
Not checked
Source
[1]
CSA-C22.2 No.107.1-95manufacturer claimpresent at observation[1]
Scope
equipment listing
Covered models
tristar-45
Limitations
Printed in the manufacturer's own datasheet Certifications block, captured September 28, 2026; no certificate number or issuer file number is given, so it is a manufacturer claim and not issuer-verified.
Record detail
Issued: Not stated
Valid from: Not stated
Expiry: Not stated
Not checked
Source
[1]
IEC 62109-1manufacturer claimpresent at observation[1]
Scope
unresolved document set
Covered models
tristar-45
Limitations
Printed in the manufacturer's own datasheet Certifications block, captured September 28, 2026; no certificate number or issuer file number is given, so it is a manufacturer claim and not issuer-verified.
Record detail
Issued: Not stated
Valid from: Not stated
Expiry: Not stated
Not checked
Source
[1]
EN 60335-1manufacturer claimpresent at observation[1]
Scope
unresolved document set
Covered models
tristar-45
Limitations
Printed in the manufacturer's own datasheet Certifications block, captured September 28, 2026; no certificate number or issuer file number is given, so it is a manufacturer claim and not issuer-verified.
Record detail
Issued: Not stated
Valid from: Not stated
Expiry: Not stated
Not checked
Source
[1]
EN 60335-2-29manufacturer claimpresent at observation[1]
Scope
unresolved document set
Covered models
tristar-45
Limitations
Printed in the manufacturer's own datasheet Certifications block, captured September 28, 2026; no certificate number or issuer file number is given, so it is a manufacturer claim and not issuer-verified.
Record detail
Issued: Not stated
Valid from: Not stated
Expiry: Not stated
Not checked
Source
[1]

Warranty

Unknown: no warranty facts recorded.

Recalls / legal notices

No recalls on file. All notices · Report a notice

This register is incomplete. A missing notice does not establish that a product has no recalls.

Documents

Archive and older revisions

Archive and older revisions0

Earlier revisions, archived captures and copies published by someone other than the manufacturer. Every one stays reachable.

Archived documents

Morningstar's own TriStar (PWM) datasheet, control no. MS-001798, revision 3/2025, from morningstarcorp.com's own TriStar product page.

Archived copy of a document published by Morningstar. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].

Archived backupRevision not recorded · 0.24 MB

Archived copy, unaltered, kept as a record of what Morningstar published. Original address: https://www.morningstarcorp.com/wp-content/uploads/datasheet-tristar-en.pdf. Copyright and takedown

Source first found
This copy captured
Archived
File detailsOriginal source
Embedded creation date
Embedded modification date
Pages
2

Embedded dates are file metadata, not independent proof of publication.

SHA-256: 50078faad81c76be986e473c003974b935d0d95649474b3281d803c43afac1b6

Morningstar TriStar Solar Charging System Controller Installation, Operation and Maintenance Manual (MS-001156 v4.7)

Archived copy of a document published by Morningstar. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].

Archived backupMS-001156 v4.7 · 0.85 MB

Archived copy, unaltered, kept as a record of what Morningstar published. Original address: https://www.morningstarcorp.com/wp-content/uploads/operation-manual-tristar-en.pdf. Copyright and takedown

Source first found
This copy captured
Archived
File detailsOriginal source
Embedded creation date
Embedded modification date
Pages
39

Embedded dates are file metadata, not independent proof of publication.

SHA-256: 702ce615ba67f91b8517e2943c8a61fc6734ef24f633be0b0db3191f3a338df5

Submit a document

Parts and accessories

No sourced accessories or replacement parts listed yet.

Model history

Model identity

Model
TS-45

Manufacturer SKU TS-45

No historical observations recorded yet.

Other recorded fields

FieldValueConditionsSource
Evidence breakdownUnknown

Community discussions

No discussions linked yet. Search DIY Solar Forum

Sources

  1. Morningstar's own TriStar (PWM) datasheet, control no. MS-001798, revision 3/2025, from morningstarcorp.com's own TriStar product page. (Morningstar · manufacturer · observed Sep 27, 2026)
  2. Morningstar TriStar Solar Charging System Controller Installation, Operation and Maintenance Manual (MS-001156 v4.7) (Morningstar · manufacturer · MS-001156 v4.7 · observed Oct 1, 2026)

Sign in to report an error on this page

Similar products

All with a price