About brandMorningstar Corporation, based in Newtown, Pennsylvania since 1993, makes solar charge controllers and inverters used in off-grid, industrial and hazardous-location power systems worldwide; its datasheets describe the company as employee-owned with well over three million products made.
SKU detail
locator: VERSIONS / Ratings row
conditions: Printed as one of nine current SunSaver PWM versions listed together in the datasheet's own Ratings row.
Printed as "Safety: EN60335-1 and EN60335-2-29 (battery chargers)" in Morningstar's SunSaver Installation and Operation Manual (MS-001272 v4.1), section 2.3, the safety standards the SunSaver controllers are stated to comply with. Section 2.3 also lists EMC standards EN61000-6-2:1999 and EN55022:1994. These are the maker's claims as printed, not checked against any directory.
Where: PDF page 7, section 2.3 (Regulatory Information)
The SunSaver is a negative ground controller.; Any one negative conductor can be earth grounded as required.; Grounding is recommended, but not required for correct operation.
Printed as "The SunSaver is a negative ground controller. Any one negative conductor can be earth grounded as required. Grounding is recommended, but not required for correct operation." in Morningstar's SunSaver Installation and Operation Manual (MS-001272 v4.1), the section 3.4 notes, for all SunSaver models.
Printed as "WARM AIR COOL AIR AT LEAST 2” (51 mm) AT LEAST 2” (51 mm)" in Morningstar's SunSaver Installation and Operation Manual (MS-001272 v4.1), Figure 3 (Mounting and cooling) of section 3.3, for all SunSaver models.
Where: PDF page 11, section 3.3 (Mounting), Step 2 and Figure 3
Printed as "Max. Load Current 6 A 10 A 20 A" in Morningstar's SunSaver Installation and Operation Manual (MS-001272 v4.1), the Specification Summary inside the front cover (columns SS-6/6L, SS-10/10L, SS-20L); 6 A is the column for the SS-6-12V. Re-cited on 1 October 2026 to the manufacturer's own document; previously cited to Morningstar (morningstarcorp.com), which stays listed as an additional source.
Where: PDF page 2, Specification Summary, Max. Load Current row
Maximum pv input current as printed in Morningstar SunSaver PV System Controllers Installation and Operation Manual (MS-001272 v4.1): "6.5", Ratings, Max. Solar Current row, SS-6/6L column.
Where: Ratings, Max. Solar Current row, SS-6/6L column
Printed as "Max. solar input voltage 30 or 60V" in Morningstar's SunSaver Installation and Operation Manual (MS-001272 v4.1), section 7.0 Electrical; 30V is for 12 V and 60V for 24 V models, so 30V applies to the SS-6-12V. Re-cited on 1 October 2026 to the manufacturer's own document; previously cited to Morningstar (morningstarcorp.com), which stays listed as an additional source.
Where: PDF page 23, section 7.0, Electrical, Max. solar input voltage row
Printed as "Power terminals wire size (max.) Solid #10 AWG / 5 mm2 Multistrand #10 AWG / 5 mm2 Fine strand #10 AWG / 5 mm2" in Morningstar's SunSaver Installation and Operation Manual (MS-001272 v4.1), section 7.0 Mechanical, printed once for all SunSaver models (solid, multistrand and fine strand). The wire charts on PDF pages 24 and 25 give sizes by current and one-way distance; the Fusing Chart limits fuses to 15 Amps on 14 AWG, 20 Amps on 12 AWG and 30 Amps on 10 AWG.
Where: PDF page 24, section 7.0, Mechanical, Power terminals wire size (max.)
in-line fuse holder no more than 6 inches (150 mm) from the battery positive terminal, or a circuit breaker
Printed as "Wire an in-line fuse holder no more than 6 inches (150" in Morningstar's SunSaver Installation and Operation Manual (MS-001272 v4.1), section 3.4, Step 2, a statement for all SunSaver models. Fuse size follows the Fusing Chart on PDF page 24 (maximum 15 Amps on 14 AWG, 20 Amps on 12 AWG and 30 Amps on 10 AWG copper wire).
Where: PDF page 13, section 3.4, Step 2 (Battery Wiring)
Printed as "Power terminals torque (max.) 10.6 in-lb / 1.2 Nm" in Morningstar's SunSaver Installation and Operation Manual (MS-001272 v4.1), section 7.0 Mechanical, printed once for all SunSaver models.
Where: PDF page 24, section 7.0, Mechanical, Power terminals torque (max.) row
Printed as "Sealed 12 V or 24 V Flooded/AGM 12 V or 24 V" in Morningstar's SunSaver Installation and Operation Manual (MS-001272 v4.1), the section 7.0 Battery Set-points table (columns Sealed and Flooded/AGM). Section 3.1 (PDF page 8) says "The SunSaver charging algorithm is compatible with lead-acid or NiCd batteries. NiMH, Li-ion, and other battery chemistries are not compatible with the SunSaver charging algorithm."
Where: PDF page 23, section 7.0, Battery Set-points table
Printed as "Locate the SunSaver on a vertical surface protected from direct sun, high temperatures, and water." in Morningstar's SunSaver Installation and Operation Manual (MS-001272 v4.1), section 3.3, Step 1, for all SunSaver models. The same step says mounting on a horizontal surface does not provide optimal airflow and could lead to overheating.
Where: PDF page 11, section 3.3 (Mounting), Step 1
Printed as "Power terminals torque (max.) 10.6 in-lb / 1.2 Nm" in Morningstar's SunSaver Installation and Operation Manual (MS-001272 v4.1), section 7.0 Mechanical, printed once for all SunSaver models.
Where: PDF page 24, section 7.0, Mechanical, Power terminals torque (max.) row
Printed as "Battery voltage range 6 -15V or 6-30V" in Morningstar's SunSaver Installation and Operation Manual (MS-001272 v4.1), section 7.0 Electrical; the first figure is for 12 V and the second for 24 V models, so 6 -15V applies to the 12 V SS-6-12V.
Where: PDF page 23, section 7.0, Electrical, Battery voltage range row
What this shows: what each record says and how far it reaches. It does not mean the product is approved.
StandardEvidenceStatusSource
UL 1741manufacturer claimpresent at observation[1]
Scope
equipment listing
Covered models
sunsaver-ss-6-12v
Limitations
Printed in the manufacturer's own datasheet Certifications block, captured September 28, 2026; no certificate number or issuer file number is given, so it is a manufacturer claim and not issuer-verified.
CSA C22.2 No. 213-M1987manufacturer claimpresent at observation[1]
Scope
equipment listing
Covered models
sunsaver-ss-6-12v
Limitations
Printed in the manufacturer's own datasheet Certifications block, captured September 28, 2026; no certificate number or issuer file number is given, so it is a manufacturer claim and not issuer-verified.
IEC/EN 62109-1manufacturer claimpresent at observation[1]
Scope
unresolved document set
Covered models
sunsaver-ss-6-12v
Limitations
Printed in the manufacturer's own datasheet Certifications block, captured September 28, 2026; no certificate number or issuer file number is given, so it is a manufacturer claim and not issuer-verified.
FCC Title 47 Part 15 Subpart Bmanufacturer claimpresent at observation[1]
Scope
unresolved document set
Covered models
sunsaver-ss-6-12v
Limitations
Printed in the manufacturer's own datasheet Certifications block, captured September 28, 2026; no certificate number or issuer file number is given, so it is a manufacturer claim and not issuer-verified.
UL1604/ANSI/ISA 12.12.01-2000manufacturer claimpresent at observation[1]
Scope
unresolved document set
Covered models
sunsaver-ss-6-12v
Limitations
Printed in the manufacturer's own datasheet Certifications block, captured September 28, 2026; no certificate number or issuer file number is given, so it is a manufacturer claim and not issuer-verified.
Location: Cover page (SunSaver Models Included in this Manual) and section 7.0 (Technical Specifications)
Retrieved Oct 1, 2026
Morningstar's own installation, operation and maintenance manual for the SunSaver models SS-6-12V / SS-6L-12V, SS-10-12V, SS-10L-12V / SS-10L-24V and SS-20L-12V / SS-20L-24V, captured 1 October 2026 from morningstarcorp.com, where the product page links it; revision MS-001272 v4.1 as printed on the back cover. Manufacturer instructions and specifications, not independent tests.
Archived copies
Archived copy of a document published by Morningstar. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
UL 1741Manufacturer claim · equipment listingClaimedListed when checked
Printed in the manufacturer's own datasheet Certifications block, captured September 28, 2026; no certificate number or issuer file number is given, so it is a manufacturer claim and not issuer-verified.
CSA C22.2 No. 213-M1987Manufacturer claim · equipment listingClaimedListed when checked
Printed in the manufacturer's own datasheet Certifications block, captured September 28, 2026; no certificate number or issuer file number is given, so it is a manufacturer claim and not issuer-verified.
IEC/EN 62109-1Manufacturer claim · unresolved document setClaimedListed when checked
Printed in the manufacturer's own datasheet Certifications block, captured September 28, 2026; no certificate number or issuer file number is given, so it is a manufacturer claim and not issuer-verified.
FCC Title 47 Part 15 Subpart BManufacturer claim · unresolved document setClaimedListed when checked
Printed in the manufacturer's own datasheet Certifications block, captured September 28, 2026; no certificate number or issuer file number is given, so it is a manufacturer claim and not issuer-verified.
UL1604/ANSI/ISA 12.12.01-2000Manufacturer claim · unresolved document setClaimedListed when checked
Printed in the manufacturer's own datasheet Certifications block, captured September 28, 2026; no certificate number or issuer file number is given, so it is a manufacturer claim and not issuer-verified.
Captured by scripts/prepare-brand-sweep-sep21.mjs on 2026-09-28.
Location: VERSIONS/Ratings table and Technical Specifications block
Retrieved Sep 27, 2026
Primary source for the SunSaver PWM models.
Archived copies
Archived copy of a document published by Morningstar. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Earlier revisions, archived captures and copies published by someone other than the manufacturer. Every one stays reachable.
Archived documents
Morningstar's own SunSaver (PWM) datasheet, control #MS-002634 REV 6/2026.EN, from morningstarcorp.com's own SunSaver product page.
Archived copy of a document published by Morningstar. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Morningstar SunSaver PV System Controllers Installation and Operation Manual (MS-001272 v4.1)