Charged ReviewsSaved 0Compare 0Login
Morningstar ProStar MPPT 25A Solar Controller
Morningstar
Charge controller

Morningstar ProStar MPPT 25A Solar Controller

5.0 (1 owner review)Write a review

Key specs

Charge current25 A
Weight1.4 kg
Max PV voltage120 V
Load output25 A

All specifications

Identity

BrandMorningstar · Website
ModelPS-MPPT-25
MarketUnknown
Manufacturer SKUPS-MPPT-25
About brandMorningstar Corporation, based in Newtown, Pennsylvania since 1993, makes solar charge controllers and inverters used in off-grid, industrial and hazardous-location power systems worldwide; its datasheets describe the company as employee-owned with well over three million products made.
SKU detail
locator: Versions line
conditions: Printed as this model's own version designation (the meter-equipped "M" suffix versions, PS-MPPT-25M and PS-MPPT-40M, are built as separate records: same electrical specifications, only a factory-fitted meter).
Sources: [1]
FieldValueConditionsSource
ListingUL1741; CSA C22.2#107.1-01; UL121201/CSA C22.2 #213; IEC/EN 62109-1
Printed as "UL1741 INVERTERS, CONVERTERS, AND CONTROLLERS AND INTERCONNECTION SYSTEM EQUIPMENT FOR USE WITH DISTRIBUTED ENERGY SOURCES" in Morningstar's ProStar MPPT Operator's Manual (MS-001537 v3.8), the ProStar MPPT Addendum to Operator's Manual, Certifications, a list for the ProStar MPPT. UL121201/CSA C22.2 #213 covers Class I, Division 2 hazardous locations. These are the maker's claims as printed, not checked against the listing bodies' directories.
Where: PDF page 46, Certifications addendum
[2]
GroundingUse copper wire to connect the grounding terminal in the case, and other dead metal, to earth ground.; DO NOT bond DC system electrical negative to earth grounding terminal on the controller.
Printed as "Use copper wire to connect the grounding terminal in the case, and other dead metal, to earth ground." in Morningstar's ProStar MPPT Operator's Manual (MS-001537 v3.8), Step 4, a statement for all ProStar MPPT models. The manual says the unit has no internal ground fault protection and must be used with an external GFDI device where Article 690 of the National Electrical Code requires one.
Where: PDF page 20, section 3.4.3, Step 4 (Grounding and Ground Fault Interruption)
[2]
Weight1.4 kg
Printed as a single standard-enclosure value shared across both models; a wire-box option changes this figure.
Where: Mechanical Specifications, Weight row
[1]
PV wire size#14 - 2 AWG (2.5 - 33.6 mm2); maximum #6 AWG (16 mm2) with the standard terminal cover
Printed as "The power terminals are sized for #14 - 2 AWG (2.5 - 33.6 mm2) wire." in Morningstar's ProStar MPPT Operator's Manual (MS-001537 v3.8), section 3.4.1, a statement for all ProStar MPPT power terminals. Up to #2 AWG only inside an enclosure or with the Wiring Box accessory. The manual requires PV wire ampacity of at least 156% of the PV array Isc.
Where: PDF page 15, section 3.4.1 (Wire Sizing)
[2]
Clearancesat least 15 cm (6 in) of space above and below the controller, and 50 mm (2 in) at the sides
Printed as "allow at least 15 cm (6 in) of space above and below the controller, and 50 mm (2 in) at the sides" in Morningstar's ProStar MPPT Operator's Manual (MS-001537 v3.8), section 3.3, a statement for all ProStar MPPT models.
Where: PDF page 14, section 3.3 (Mounting)
[2]
DimensionsW 200 × L 194 × D 70 mm / W 7.87 × L 7.62 × D 2.76 in Check note
The manual and the data sheet print different dimensions. Morningstar's ProStar MPPT Operator's Manual (MS-001537 v3.8) prints 20.0(W) x 19.4(L) x 7.0(D) cm for the standard version; Morningstar's ProStar MPPT data sheet prints 20 x 17 x 7 cm.
Printed as "Dimensions: Standard 7.87(W) x 7.62(L) x 2.76(D) in. / 20.0(W) x 19.4(L) x 7.0(D) cm" in Morningstar's ProStar MPPT Operator's Manual (MS-001537 v3.8), section 7.0, the Standard version (without the Wire Box option). With the Wire Box option the manual prints 20.0 (W) x 28.5 (L) x 9.2(D) cm. Revised on 1 October 2026: The installation and operation manual is the primary source; its standard-version length (19.4 cm) differs from the data sheet figure (17 cm). Revised on 13 October 2026: stored as text before; converted to numbers using the axis order the document prints (width x length x depth).
Where: PDF page 40, section 7.0, Mechanical, Dimensions: Standard row
Sources
Converted: 20 x 19.4 x 7 cm x 10 mm/cm
20 × 17 × 7 cm

Printed as a single standard-enclosure value shared across both models; a wire-box option changes this figure.

[1]
[2]
Load output25 A
Printed as "Load Current Rating 25 Amps 30 Amps" in Morningstar's ProStar MPPT Operator's Manual (MS-001537 v3.8), section 7.0; 25 Amps is the PS-MPPT-25 column. Re-cited on 1 October 2026 to the manufacturer's own document; previously cited to Morningstar (morningstarcorp.com), which stays listed as an additional source.
Where: PDF page 40, section 7.0, Electrical, Load Current Rating row, PS-MPPT-25 column
[2] [1]
PV disconnect40 Amps
Printed as "Maximum PV breaker or fuse ratings are:" in Morningstar's ProStar MPPT Operator's Manual (MS-001537 v3.8), section 3.4.2, the maximum PV breaker or fuse rating for the PS-MPPT-25. PV input disconnect switches must be rated at least 1.25 times the PV array Isc.
Where: PDF page 17, section 3.4.2, PV input disconnect and over-current protection device sizing
[2]
CommunicationsMeterBus, MODBUS, SNMP (enabled through EMC-1)Printed as a single value shared across both models.
Where: Data & Communications block
[1]
Efficiency97.3 % Check note
The manual and the data sheet print different peak efficiencies. Morningstar's ProStar MPPT Operator's Manual (MS-001537 v3.8) prints a peak conversion efficiency of 97.3%; Morningstar's ProStar MPPT data sheet prints 98%.
Printed as "Conversion Efficiency (peak) All: 97.3%" in Morningstar's ProStar MPPT Operator's Manual (MS-001537 v3.8), section 7.0, printed once for all ProStar MPPT models. Revised on 1 October 2026: The installation and operation manual is the primary source; it prints a peak conversion efficiency of 97.3%, while the data sheet prints 98%.
Where: PDF page 40, section 7.0, Electrical, Conversion Efficiency (peak) row
Sources
98 %

Printed as a single peak efficiency value shared across both models.

[1]
[2]
Controller typeMPPTPrinted in the datasheet's own product name.
Where: Title
[1]
Charge current25 A
Printed as "Max. Battery Current 25 Amps 40 Amps" in Morningstar's ProStar MPPT Operator's Manual (MS-001537 v3.8), section 7.0; 25 Amps is the PS-MPPT-25 column (columns PS-MPPT-25, PS-MPPT-40). Re-cited on 1 October 2026 to the manufacturer's own document; previously cited to Morningstar (morningstarcorp.com), which stays listed as an additional source.
Where: PDF page 40, section 7.0, Electrical, Max. Battery Current row, PS-MPPT-25 column
[2] [1]
Enclosure ratingIP20, Type 1Printed as a single value shared across both models.
Where: Mechanical Specifications, Enclosure row
[1]
Ground wire size10 AWG (5 mm2)
Printed as "ProStar MPPT-25 10 AWG (5 mm2)" in Morningstar's ProStar MPPT Operator's Manual (MS-001537 v3.8), Step 4, the minimum equipment copper grounding wire size per NEC printed for the ProStar MPPT-25. Per IEC 62109 the manual prints "ProStar MPPT-25 7 AWG (10 mm2)", or a wire of the same or greater cross-sectional area as the PV wires.
Where: PDF page 20, section 3.4.3, Step 4 (Grounding and Ground Fault Interruption)
[2]
Max PV voltage120 V
Printed as "Max. PV Open-Circuit Voltage All: 120 Volts" in Morningstar's ProStar MPPT Operator's Manual (MS-001537 v3.8), section 7.0, printed once for all ProStar MPPT models. Re-cited on 1 October 2026 to the manufacturer's own document; previously cited to Morningstar (morningstarcorp.com), which stays listed as an additional source.
Where: PDF page 40, section 7.0, Electrical, Max. PV Open-Circuit Voltage row
[2] [1]
Battery voltage12V or 24V
Printed as a single value shared across both models.
Where: Electrical block, Nominal Battery Voltage row
[1]
Battery wire size10 AWG at 30ºC, 8 AWG above 35°C, 6 above 55ºC (raceway, cable, or earth); 10 AWG (free air); 6-10 mm2
Printed as "PS-MPPT 25 10 AWG 8 AWG > 35°C 6 > 55ºC 10 AWG 10 AWG 6-10" in Morningstar's ProStar MPPT Operator's Manual (MS-001537 v3.8), Table C-1, the PS-MPPT-25 row (columns: wire size in a raceway, cable, or earth at 30ºC and 30º-60ºC; in free air at 30ºC and 30º-45ºC; metric size in mm2). Minimum sizes for 75ºC or 90ºC rated stranded copper. Section 3.4.1 (PDF page 15) says the power terminals are sized for #14 - 2 AWG (2.5 - 33.6 mm2) wire, with #6 AWG the maximum under the standard terminal cover.
Where: PDF page 44, Appendix C, Table C-1 (Minimum DC battery wire sizes), PS-MPPT-25 row
[2]
Battery protection40 Amps
Printed as "PS-MPPT-25: 40 Amps" in Morningstar's ProStar MPPT Operator's Manual (MS-001537 v3.8), section 3.4.2, the recommended battery circuit fuse or breaker rating for the PS-MPPT-25. Section 3.1 (PDF page 13) requires over-current protection interrupt ratings of at least 2000A for 12V systems and 4000A for 24V systems.
Where: PDF page 17, section 3.4.2, Battery disconnect and over-current protection device sizing
[2]
Max PV input power700W / 880W W
Printed as this model's own nominal output power and max recommended solar PV input on a 24 volt battery, the higher of the two nominal voltages; the 12 volt battery figure is kept as an alternative.
Where: Electrical block, Nominal Maximum Output Power / Max Recommended Solar PV Input row
Sources
350W / 440W W

Printed as this model's own nominal output power and max recommended solar PV input on a 12 volt battery.

[1]
[1]
PV terminal torque35 in-lb
Printed as "torque tightly up to 35 in-lb" in Morningstar's ProStar MPPT Operator's Manual (MS-001537 v3.8), section 3.4.1, for all ProStar MPPT power terminals. Section 7.0 (PDF page 40) prints "Maximum torque 35 in-lb" for the power terminals.
Where: PDF page 15, section 3.4.1 (Wire Sizing)
[2]
Self consumption~0.6W (no meter) ~1.0W (w/backlit meter)
Printed as "Self-Consumption All: ~0.6W (no meter) ~1.0W (w/backlit meter)" in Morningstar's ProStar MPPT Operator's Manual (MS-001537 v3.8), section 7.0, printed once for all ProStar MPPT models. The manual states self-consumption in watts, not milliamps.
Where: PDF page 40, section 7.0, Electrical, Self-Consumption row
[2]
Communication portsMeterBus port (RJ-11)
Printed as "11 - MeterBusTM Port RJ-11 socket for Morningstar MeterBusTM network connections" in Morningstar's ProStar MPPT Operator's Manual (MS-001537 v3.8), section 2.4 Features, item 11. Section 7.0 (PDF page 41) lists the communication protocols "Morningstar MeterBus; MODBUS".
Where: PDF page 10, section 2.4 (Features), item 11
[2]
Supported chemistrySealed; AGM/Flooded; Flooded; L-16; Custom
Printed as "off-off-off 1 - Sealed* 14.00" in Morningstar's ProStar MPPT Operator's Manual (MS-001537 v3.8), Table 3.1, the battery types selectable with DIP switches 4, 5 and 6. The table's footnote says the "Sealed" battery type includes gel and AGM batteries.
Where: PDF page 14, section 3.2, Table 3.1 (battery charging settings for each selectable battery type)
[2]
Max PV input power12: 440, 24: 880 W
Printed in the "Nominal Maximum Output Power / Max Recommended Solar PV Input" rows of Morningstar's ProStar MPPT data sheet: "12 volt battery 350W / 440W" and "24 volt battery 700W / 880W" in the PS-MPPT-25 column; the second figure of each pair is the max recommended solar PV input. Footnote: "The PV array power rating may exceed the controller's Max Nominal Output Power specification."
Where: Electrical block, Nominal Maximum Output Power / Max Recommended Solar PV Input rows, PS-MPPT-25 column
[1]
Mounting orientationvertical surface; heat sink fins up and down
Printed as "Mount the ProStar MPPT to a vertical surface" in Morningstar's ProStar MPPT Operator's Manual (MS-001537 v3.8), section 3.3, a statement for all ProStar MPPT models.
Where: PDF page 14, section 3.3 (Mounting)
[2]
Battery terminal torque35 in-lb
Printed as "torque tightly up to 35 in-lb" in Morningstar's ProStar MPPT Operator's Manual (MS-001537 v3.8), section 3.4.1, for all ProStar MPPT power terminals. Section 7.0 (PDF page 40) prints "Maximum torque 35 in-lb" for the power terminals.
Where: PDF page 15, section 3.4.1 (Wire Sizing)
[2]
Battery voltage range10-35 Volts
Printed as "Battery Voltage Range All: 10-35 Volts" in Morningstar's ProStar MPPT Operator's Manual (MS-001537 v3.8), section 7.0, printed once for all ProStar MPPT models.
Where: PDF page 40, section 7.0, Electrical, Battery Voltage Range row
[2]
Operating temperature-40°C to +60°C
Printed as "T4 Certified -40°C to +60°C T5 Certified -40°C to +45°C" in Morningstar's ProStar MPPT Operator's Manual (MS-001537 v3.8), section 7.0, Ambient Temperature Range, the T4 Certified figure; printed once for all ProStar MPPT models. The T5 Certified range is -40°C to +45°C. Re-cited on 1 October 2026 to the manufacturer's own document; previously cited to Morningstar (morningstarcorp.com), which stays listed as an additional source.
Where: PDF page 41, section 7.0, Environmental, Ambient Temperature Range
[2] [1]

Owner reviews

5.0 (1 owner review)
5/5

@friendly_porcupine 0 points · Unverified ·

Great product. Mine are the version with the built in meter.

Reliability
5/5
Build quality
5/5
Ease of install
5/5

I put two of these into service in 2007 and 2008 on small off-grid systems. Both are working perfectly. The optional built in meter is really convenient, so I recommend getting the version with the meter.

Helpful? Sign in to vote
Request removal

Published reviews are their authors’ statements. A request about personal information is normally answered by anonymizing the review rather than removing it, unless the law requires removal.

Write a review

Sellers

No listed sellers in this data.

Price history

No seller price history.

Quick reference sheet

Controller type
MPPT
Maximum PV voltage (Voc)
120 V
Rated charge current
25 A
Battery voltages
12V or 24V
Maximum PV input power
700W / 880W
Peak efficiency
Not stated

Evidence score

This category has no Evidence score.

Certificates

What this shows: what each record says and how far it reaches. It does not mean the product is approved.
UL 1741manufacturer claimpresent at observation[1]
Scope
equipment listing
Covered models
prostar-mppt-25
Limitations
Printed in the manufacturer's own datasheet Certifications block, captured September 28, 2026; no certificate number or issuer file number is given, so it is a manufacturer claim and not issuer-verified.
Record detail
Issued: Not stated
Valid from: Not stated
Expiry: Not stated
Not checked
Source
[1]
CSA C22.2 No.107.1manufacturer claimpresent at observation[1]
Scope
equipment listing
Covered models
prostar-mppt-25
Limitations
Printed in the manufacturer's own datasheet Certifications block, captured September 28, 2026; no certificate number or issuer file number is given, so it is a manufacturer claim and not issuer-verified.
Record detail
Issued: Not stated
Valid from: Not stated
Expiry: Not stated
Not checked
Source
[1]
IEC 62109-1manufacturer claimpresent at observation[1]
Scope
unresolved document set
Covered models
prostar-mppt-25
Limitations
Printed in the manufacturer's own datasheet Certifications block, captured September 28, 2026; no certificate number or issuer file number is given, so it is a manufacturer claim and not issuer-verified.
Record detail
Issued: Not stated
Valid from: Not stated
Expiry: Not stated
Not checked
Source
[1]
FCC Part-15 Class Bmanufacturer claimpresent at observation[1]
Scope
unresolved document set
Covered models
prostar-mppt-25
Limitations
Printed in the manufacturer's own datasheet Certifications block, captured September 28, 2026; no certificate number or issuer file number is given, so it is a manufacturer claim and not issuer-verified.
Record detail
Issued: Not stated
Valid from: Not stated
Expiry: Not stated
Not checked
Source
[1]
UL121201/CSA C22.2 #213manufacturer claimpresent at observation[1]
Scope
unresolved document set
Covered models
prostar-mppt-25
Limitations
Printed in the manufacturer's own datasheet Certifications block, captured September 28, 2026; no certificate number or issuer file number is given, so it is a manufacturer claim and not issuer-verified.
Record detail
Issued: Not stated
Valid from: Not stated
Expiry: Not stated
Not checked
Source
[1]
ATEXmanufacturer claimpresent at observation[1]
Scope
unresolved document set
Covered models
prostar-mppt-25
Limitations
Printed in the manufacturer's own datasheet Certifications block, captured September 28, 2026; no certificate number or issuer file number is given, so it is a manufacturer claim and not issuer-verified.
Record detail
Issued: Not stated
Valid from: Not stated
Expiry: Not stated
Not checked
Source
[1]
IECExmanufacturer claimpresent at observation[1]
Scope
unresolved document set
Covered models
prostar-mppt-25
Limitations
Printed in the manufacturer's own datasheet Certifications block, captured September 28, 2026; no certificate number or issuer file number is given, so it is a manufacturer claim and not issuer-verified.
Record detail
Issued: Not stated
Valid from: Not stated
Expiry: Not stated
Not checked
Source
[1]

Warranty

FieldValueConditionsSource
Warranty term5 yearsPrinted as a single warranty statement shared across both models.
Where: Final page, WARRANTY line
[1]

Recalls / legal notices

No recalls on file. All notices · Report a notice

This register is incomplete. A missing notice does not establish that a product has no recalls.

Documents

Archive and older revisions

Archive and older revisions0

Earlier revisions, archived captures and copies published by someone other than the manufacturer. Every one stays reachable.

Archived documents

Morningstar's own ProStar MPPT datasheet, control #MS-001724 REV 01/2025.EN, from morningstarcorp.com's own ProStar MPPT product page.

Archived copy of a document published by Morningstar. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].

Archived backupRevision not recorded · 0.14 MB

Archived copy, unaltered, kept as a record of what Morningstar published. Original address: https://www.morningstarcorp.com/wp-content/uploads/datasheet-prostar-mppt-en.pdf. Copyright and takedown

Source first found
This copy captured
Archived
File detailsOriginal source
Embedded creation date
Embedded modification date
Pages
2

Embedded dates are file metadata, not independent proof of publication.

SHA-256: a4b07ab7c32a1bd185d9012bf9f95fc0db6da6d436e190e0be89f20b1c10c636

Morningstar ProStar MPPT Solar Charging System Controller Installation, Operation and Maintenance Manual (MS-001537 v3.8)

Archived copy of a document published by Morningstar. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].

Archived backupMS-001537 v3.8 · 1.77 MB

Archived copy, unaltered, kept as a record of what Morningstar published. Original address: https://www.morningstarcorp.com/wp-content/uploads/operation-manual-prostar-mppt-en.pdf. Copyright and takedown

Source first found
This copy captured
Archived
File detailsOriginal source
Embedded creation date
Embedded modification date
Pages
47

Embedded dates are file metadata, not independent proof of publication.

SHA-256: 47a6922fde1edba48646ca2f9d6a4011cbceb85461eb40afe79103b1051c110b

Submit a document

Parts and accessories

No sourced accessories or replacement parts listed yet.

Model history

Model identity

Model
PS-MPPT-25

Manufacturer SKU PS-MPPT-25

No historical observations recorded yet.

Other recorded fields

FieldValueConditionsSource
Evidence breakdownUnknown

Community discussions

No discussions linked yet. Search DIY Solar Forum

Sources

  1. Morningstar's own ProStar MPPT datasheet, control #MS-001724 REV 01/2025.EN, from morningstarcorp.com's own ProStar MPPT product page. (Morningstar · manufacturer · observed Sep 27, 2026)
  2. Morningstar ProStar MPPT Solar Charging System Controller Installation, Operation and Maintenance Manual (MS-001537 v3.8) (Morningstar · manufacturer · MS-001537 v3.8 · observed Oct 1, 2026)

Sign in to report an error on this page

Similar products

All with a price