About brandMorningstar Corporation, based in Newtown, Pennsylvania since 1993, makes solar charge controllers and inverters used in off-grid, industrial and hazardous-location power systems worldwide; its datasheets describe the company as employee-owned with well over three million products made.
SKU detail
locator: Versions list
conditions: Printed as this model's own version, no meter (its meter-equipped "M" version, PS-30M, is built as a separate record: a factory-fitted meter, with a higher self-consumption printed for it).
Printed as "PROSTAR GEN 3 ADDENDUM TO OPERATOR’S MANUAL Certifications UL1741" in Morningstar's ProStar Operator's Manual (MS-001533 v4.3), the ProStar Gen 3 Addendum, Certifications, a list for the ProStar. UL121201/CSA C22.2 #213 covers Class I, Division 2 hazardous locations. These are the maker's claims as printed, not checked against the listing bodies' directories.
Where: PDF page 49, ProStar Gen 3 Addendum to Operator's Manual, Certifications
DO NOT bond DC system electrical negative to earth grounding terminal on the controller.; system negative must be bonded to earth ground at only one point, and through a GFPD, if required
Printed as "DO NOT bond DC system electrical negative to earth grounding terminal on the controller." in Morningstar's ProStar Operator's Manual (MS-001533 v4.3), the grounding step of section 3.4.3, a statement for all ProStar models. The safety section (PDF page 6) adds that a permanent, reliable earth ground must be established with connection to the ProStar ground terminal.
Printed as "The power terminals are sized for #14 - 6 AWG (2.5 - 13.3 mm2) wire." in Morningstar's ProStar Operator's Manual (MS-001533 v4.3), section 3.4.1, a statement for all ProStar power terminals. The manual requires PV input wire ampacity of at least 156% of the PV array Isc.
at least 15 cm (6 in) of space above and below the controller, and 50 mm (2 in) at the sides
Printed as "allow at least 15 cm (6 in) of space above and below the controller, and 50 mm (2 in) at the sides" in Morningstar's ProStar Operator's Manual (MS-001533 v4.3), section 3.3, a statement for all ProStar models.
Printed as a single value shared across both models. Printed as "Dimensions: 15.3(W) x 10.5(L) x 5.5(D) cm / 6.0(W) x 4.1(L) x 2.2(D) in" in Morningstar's ProStar datasheet. Revised on 13 October 2026: stored as text before; converted to numbers using the axis order the document prints (width x length x depth).
Printed as "Load Current Rating 15 Amps 30 Amps" in Morningstar's ProStar Operator's Manual (MS-001533 v4.3), section 7.0; 30 Amps is the PS-30 column. Re-cited on 1 October 2026 to the manufacturer's own document; previously cited to Morningstar (morningstarcorp.com), which stays listed as an additional source.
Where: PDF page 45, section 7.0, Electrical, Load Current Rating row, PS-30 column
Printed as "ProStar-30 / M: 40 Amps" in Morningstar's ProStar Operator's Manual (MS-001533 v4.3), section 3.4.2, the maximum PV breaker or fuse rating for the ProStar-30 / M (list headed "Maximum PV breaker or fuse ratings are:" on PDF page 19). PV input disconnect switches must be rated at least 1.25 times the PV array Isc.
Where: PDF page 20, section 3.4.2, PV input disconnect and over-current protection device sizing
Printed as "Max. Battery Current 15 Amps 30 Amps" in Morningstar's ProStar Operator's Manual (MS-001533 v4.3), section 7.0; 30 Amps is the PS-30 column (columns PS-15, PS-30). Re-cited on 1 October 2026 to the manufacturer's own document; previously cited to Morningstar (morningstarcorp.com), which stays listed as an additional source.
Where: PDF page 45, section 7.0, Electrical, Max. Battery Current row, PS-30 column
Printed as "Max. PV Open- Circuit Voltage* 30 or 60V 30 or 60V" in Morningstar's ProStar Operator's Manual (MS-001533 v4.3), the Specification Summary (columns PS-15 / PS-15M and PS-30 / PS-30M), the PS-30 column, footnoted "Array voltage should never exceed this limit". The two figures follow the nominal battery voltage printed in the same summary ("12 or 24V"): 30V for 12 V systems and 60V for 24 V systems. Section 7.0 (PDF page 45) prints a single "60 Volts" row footnoted "Hardware specification - not for design purposes", which is not the design limit. Revised on 1 October 2026: The installation and operation manual is the primary source; its Specification Summary prints the maximum PV open-circuit voltage as 30 or 60V by system voltage (12 or 24V), a fuller statement than the single figure recorded from the data sheet.
Where: PDF page 2, Specification Summary (inside front cover), Max. PV Open-Circuit Voltage row
Sources
60 V
Printed as the maximum PV open circuit voltage for this model's own nominal battery voltage (24V bat).
ProStar-30/M: #8 AWG (10 mm2) or #10 AWG (6 mm2) if greater than 50°C inside conduit
Printed as "ProStar-30/M: #8 AWG (10 mm2) or #10 AWG (6 mm2) if greater than 50°C inside conduit" in Morningstar's ProStar Operator's Manual (MS-001533 v4.3), section 3.4.1, the minimum battery wire size printed for the ProStar-30/M. The same section says the power terminals are sized for #14 - 6 AWG (2.5 - 13.3 mm2) wire.
Printed as "Recommended battery circuit fuse or breaker current ratings:" in Morningstar's ProStar Operator's Manual (MS-001533 v4.3), section 3.4.2, the recommended battery circuit fuse or breaker rating for the ProStar-30/M. Section 3.1 (PDF page 14) requires over-current protection interrupt ratings of at least 2000A for 12V systems and 4000A for 24V systems.
Where: PDF page 19, section 3.4.2, Battery disconnect and over-current protection device sizing
Printed as "torque tightly up to 35 in-lb (4 N-m)" in Morningstar's ProStar Operator's Manual (MS-001533 v4.3), section 3.4.1, for all ProStar power terminals. Section 7.0 (PDF page 45) prints "Maximum Torque 35 in-lb (4 N-m)".
Printed as "Communication Port MeterBus (RJ-11)" in Morningstar's ProStar Operator's Manual (MS-001533 v4.3), section 7.0, printed once for all ProStar models. The protocols printed are "Morningstar MeterBus; MODBUS".
Where: PDF page 46, section 7.0, Data & Communications, Communication Port row
The manual and the data sheet print different self-consumption figures. Morningstar's ProStar Operator's Manual (MS-001533 v4.3) prints <22mA (no meter) and <40mA (meter); Morningstar's ProStar data sheet prints 20 mA.
Printed as "Self Consumption <22mA (no meter) <40mA (meter)" in Morningstar's ProStar Operator's Manual (MS-001533 v4.3), section 7.0, printed once for all ProStar models. Revised on 1 October 2026: The installation and operation manual is the primary source; it prints self-consumption as under 22 mA without the meter and under 40 mA with it, while the data sheet prints 20 mA.
Where: PDF page 45, section 7.0, Electrical, Self Consumption row
Sources
20 mA
Printed as a single maximum figure shared across both models; the datasheet separately notes 35-50 mA for metered versions.
Printed as "off-off-off 1 - Sealed* 14.00" in Morningstar's ProStar Operator's Manual (MS-001533 v4.3), section 3.2, the battery types selectable with DIP switches 4, 5 and 6. The table's footnote says the "Sealed" battery type includes gel and AGM batteries.
Printed as "Mount the ProStar to a vertical surface" in Morningstar's ProStar Operator's Manual (MS-001533 v4.3), section 3.3, a statement for all ProStar models.
Printed as "torque tightly up to 35 in-lb (4 N-m)" in Morningstar's ProStar Operator's Manual (MS-001533 v4.3), section 3.4.1, for all ProStar power terminals. Section 7.0 (PDF page 45) prints "Maximum Torque 35 in-lb (4 N-m)".
Printed as "Battery voltage Range 10-35 Volts" in Morningstar's ProStar Operator's Manual (MS-001533 v4.3), section 7.0, printed once for the PS-15, PS-30, PS-15M and PS-30M.
Where: PDF page 45, section 7.0, Electrical, Battery voltage Range row
Printed as "Ambient Temperature Range: T5 Certified -40°C to +60°C" in Morningstar's ProStar Operator's Manual (MS-001533 v4.3), section 7.0, printed once for all ProStar models. Re-cited on 1 October 2026 to the manufacturer's own document; previously cited to Morningstar (morningstarcorp.com), which stays listed as an additional source.
Where: PDF page 46, section 7.0, Environmental, Ambient Temperature Range
What this shows: what each record says and how far it reaches. It does not mean the product is approved.
StandardEvidenceStatusSource
UL 62109manufacturer claimpresent at observation[1]
Scope
equipment listing
Covered models
prostar-30
Limitations
Printed in the manufacturer's own datasheet Certifications block, captured September 28, 2026; no certificate number or issuer file number is given, so it is a manufacturer claim and not issuer-verified.
CSA 107.1manufacturer claimpresent at observation[1]
Scope
equipment listing
Covered models
prostar-30
Limitations
Printed in the manufacturer's own datasheet Certifications block, captured September 28, 2026; no certificate number or issuer file number is given, so it is a manufacturer claim and not issuer-verified.
IEC 62109manufacturer claimpresent at observation[1]
Scope
unresolved document set
Covered models
prostar-30
Limitations
Printed in the manufacturer's own datasheet Certifications block, captured September 28, 2026; no certificate number or issuer file number is given, so it is a manufacturer claim and not issuer-verified.
FCC Part-15 Class Bmanufacturer claimpresent at observation[1]
Scope
unresolved document set
Covered models
prostar-30
Limitations
Printed in the manufacturer's own datasheet Certifications block, captured September 28, 2026; no certificate number or issuer file number is given, so it is a manufacturer claim and not issuer-verified.
UL121201/CSA C22.2 #213manufacturer claimpresent at observation[1]
Scope
unresolved document set
Covered models
prostar-30
Limitations
Printed in the manufacturer's own datasheet Certifications block, captured September 28, 2026; no certificate number or issuer file number is given, so it is a manufacturer claim and not issuer-verified.
Printed in the manufacturer's own datasheet Certifications block, captured September 28, 2026; no certificate number or issuer file number is given, so it is a manufacturer claim and not issuer-verified.
Printed in the manufacturer's own datasheet Certifications block, captured September 28, 2026; no certificate number or issuer file number is given, so it is a manufacturer claim and not issuer-verified.
Location: Cover page (MODELS list) and section 7.0 (Technical Specifications)
Retrieved Oct 1, 2026
Morningstar's own installation, operation and maintenance manual for the ProStar models PS-15, PS-30, PS-15M and PS-30M (with a ProStar Gen 3 certifications addendum), captured 1 October 2026 from morningstarcorp.com, where the product page links it; revision MS-001533 v4.3 as printed on the back cover. Manufacturer instructions and specifications, not independent tests.
Archived copies
Archived copy of a document published by Morningstar. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
UL 62109Manufacturer claim · equipment listingClaimedListed when checked
Printed in the manufacturer's own datasheet Certifications block, captured September 28, 2026; no certificate number or issuer file number is given, so it is a manufacturer claim and not issuer-verified.
CSA 107.1Manufacturer claim · equipment listingClaimedListed when checked
Printed in the manufacturer's own datasheet Certifications block, captured September 28, 2026; no certificate number or issuer file number is given, so it is a manufacturer claim and not issuer-verified.
IEC 62109Manufacturer claim · unresolved document setClaimedListed when checked
Printed in the manufacturer's own datasheet Certifications block, captured September 28, 2026; no certificate number or issuer file number is given, so it is a manufacturer claim and not issuer-verified.
FCC Part-15 Class BManufacturer claim · unresolved document setClaimedListed when checked
Printed in the manufacturer's own datasheet Certifications block, captured September 28, 2026; no certificate number or issuer file number is given, so it is a manufacturer claim and not issuer-verified.
UL121201/CSA C22.2 #213Manufacturer claim · unresolved document setClaimedListed when checked
Printed in the manufacturer's own datasheet Certifications block, captured September 28, 2026; no certificate number or issuer file number is given, so it is a manufacturer claim and not issuer-verified.
ATEXManufacturer claim · unresolved document setClaimedListed when checked
Printed in the manufacturer's own datasheet Certifications block, captured September 28, 2026; no certificate number or issuer file number is given, so it is a manufacturer claim and not issuer-verified.
IECExManufacturer claim · unresolved document setClaimedListed when checked
Printed in the manufacturer's own datasheet Certifications block, captured September 28, 2026; no certificate number or issuer file number is given, so it is a manufacturer claim and not issuer-verified.
Captured by scripts/prepare-brand-sweep-sep21.mjs on 2026-09-28.
Location: Versions list and Technical Specifications block
Retrieved Sep 27, 2026
Primary source for the ProStar PWM models.
Archived copies
Archived copy of a document published by Morningstar. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Earlier revisions, archived captures and copies published by someone other than the manufacturer. Every one stays reachable.
Archived documents
Morningstar's own ProStar (PWM) datasheet, control #MS-001991 REV 01/2025.EN, from morningstarcorp.com's own ProStar product page.
Archived copy of a document published by Morningstar. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Morningstar ProStar Solar Charging System Controller Installation, Operation, and Maintenance Manual (MS-001533 v4.3)
Archived copy of a document published by Morningstar. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].