Charged Reviews
Quick reference
ACOPOWER HY-MPPT40 40A MPPT Solar Charge Controller
Model: HY-MPPT40 · SKU: HY-MPPT40
Prepared Nov 12, 2026
Common specifications
| Controller type | MPPTSource [1, 2] |
|---|---|
| Maximum PV voltage | 100V at minimum operating environment temperature; 92V at 25℃ environment temperatureSource [1, 2] |
| Maximum PV input power | Not documented |
| Maximum PV input power by battery voltage | |
| PV input current / MPPT | 40 ASource [1, 2] |
| Charge current | 40 ASource [1, 2] |
| Battery voltage | 12/24VDC AutoSource [1, 2] |
| Battery chemistry | |
| Efficiency | Not documented |
| MPPT tracking efficiency | ≥ 99.5%Source [1, 2] |
| Maximum conversion efficiency | 98 %Source [1, 2] |
| Full-load efficiency | Not documented |
| Charger efficiency | Not documented |
| Weighted efficiency | Not documented |
| Rated charge power | 520W/12V 1040W/24VSource [1, 2] |
| Load output current | 40 ASource [1, 2] |
| Self-consumption | |
| Enclosure | IP30Source [1, 2] |
| Safety listing | Not documented |
| Enclosure volume | Not documented |
| Warranty term | Not documented |
All recorded specifications
| Battery chemistry | Sealed, Gel, Flooded, UserNeeds confirmationThe 36-page HY-MPPT Series manual (V1.4) offers Sealed, Gel, Flooded and User battery types; the 40-page HY-MPPT manual (version 1.0) says "Compatible with lead-acid and lithium-ion batteries". The 36-page manual's list is recorded. ConditionsPrinted as "Battery Type ①Sealed (Default) ②Gel ③Flooded ④ User"; the overview says "Support 3 charging preprogram options: Sealed, Gel, Flooded." The User type is set through the MT50 meter or the PC software. Location: PDF page 20 (printed page 17), section 3.4 Battery Type Printed as "Battery Type ①Sealed (Default) ②Gel ③Flooded ④ User"; the overview says "Support 3 charging preprogram options: Sealed, Gel, Flooded." The User type is set through the MT50 meter or the PC software. Location: PDF page 20 (printed page 17), section 3.4 Battery Type |
|---|---|
| Battery fuse or breaker (manual) | battery fuse as close to the battery as possible, suggested within 150 mmDocumented claim ConditionsPrinted as "The battery fuse should be installed as close to battery as possible. The suggested distance is within 150mm." The 40-page manual (PDF page 15) adds "A fuse which current is 1.25 to 2 times the rated current of the controller, must be installed on the battery side with a distance from the battery not greater than 150 mm." Location: PDF page 15 (printed page 12), installation note 3 Printed as "The battery fuse should be installed as close to battery as possible. The suggested distance is within 150mm." The 40-page manual (PDF page 15) adds "A fuse which current is 1.25 to 2 times the rated current of the controller, must be installed on the battery side with a distance from the battery not greater than 150 mm." Location: PDF page 15 (printed page 12), installation note 3 Official user manual · ACOPOWER HY-MPPT Series MPPT Solar Charge Controller User Manual (HY-MPPT10/20/30/40, V1.4)Official user manual · ACOPOWER HY-MPPT Series MPPT Solar Charge Controller User Manual (HY-MPPT10/20/30/40 and Tracer1206AN/2206AN, version 1.0) [1, 2] |
| Battery operating voltage | 8V~32VDocumented claim ConditionsPrinted as "Battery input voltage range 8V~32V", shared by the four HY-MPPT columns; the 40-page manual prints "Battery voltage range 8~32V". Location: PDF page 25 (printed page 22), section 5 Technical Specifications, Electrical Parameters table, Battery input voltage range row Printed as "Battery input voltage range 8V~32V", shared by the four HY-MPPT columns; the 40-page manual prints "Battery voltage range 8~32V". Location: PDF page 25 (printed page 22), section 5 Technical Specifications, Electrical Parameters table, Battery input voltage range row Official user manual · ACOPOWER HY-MPPT Series MPPT Solar Charge Controller User Manual (HY-MPPT10/20/30/40, V1.4)Official user manual · ACOPOWER HY-MPPT Series MPPT Solar Charge Controller User Manual (HY-MPPT10/20/30/40 and Tracer1206AN/2206AN, version 1.0) [1, 2] |
| Battery voltage | 12/24VDC AutoDocumented claim ConditionsPrinted as "Nominal system voltage 12/24VDC Auto", one value shared by the four HY-MPPT columns. The 40-page manual prints "System nominal voltage 12/24VDC Auto" with a footnote that with a lithium-ion battery the system voltage can't be identified automatically. Location: PDF page 25 (printed page 22), section 5 Technical Specifications, Electrical Parameters table, Nominal system voltage row Printed as "Nominal system voltage 12/24VDC Auto", one value shared by the four HY-MPPT columns. The 40-page manual prints "System nominal voltage 12/24VDC Auto" with a footnote that with a lithium-ion battery the system voltage can't be identified automatically. Location: PDF page 25 (printed page 22), section 5 Technical Specifications, Electrical Parameters table, Nominal system voltage row Official user manual · ACOPOWER HY-MPPT Series MPPT Solar Charge Controller User Manual (HY-MPPT10/20/30/40, V1.4)Official user manual · ACOPOWER HY-MPPT Series MPPT Solar Charge Controller User Manual (HY-MPPT10/20/30/40 and Tracer1206AN/2206AN, version 1.0) [1, 2] |
| Charge current | 40 ADocumented claim ConditionsThe 36-page manual's table prints "Rated charge current 10A 20A 30A 40A" for the HY-MPPT10, HY-MPPT20, HY-MPPT30 and HY-MPPT40 columns; this is the HY-MPPT40 column. The 40-page manual (PDF page 28) prints the same 40A in its sixth (HY-MPPT 40) column, after two Tracer AN columns. Location: PDF page 25 (printed page 22), section 5 Technical Specifications, Electrical Parameters table, Rated charge current row, HY-MPPT40 column The 36-page manual's table prints "Rated charge current 10A 20A 30A 40A" for the HY-MPPT10, HY-MPPT20, HY-MPPT30 and HY-MPPT40 columns; this is the HY-MPPT40 column. The 40-page manual (PDF page 28) prints the same 40A in its sixth (HY-MPPT 40) column, after two Tracer AN columns. Location: PDF page 25 (printed page 22), section 5 Technical Specifications, Electrical Parameters table, Rated charge current row, HY-MPPT40 column Official user manual · ACOPOWER HY-MPPT Series MPPT Solar Charge Controller User Manual (HY-MPPT10/20/30/40, V1.4)Official user manual · ACOPOWER HY-MPPT Series MPPT Solar Charge Controller User Manual (HY-MPPT10/20/30/40 and Tracer1206AN/2206AN, version 1.0) [1, 2] |
| Communications | RS485 (RJ45 interface), ModbusDocumented claim ConditionsPrinted as "Communication RS485(RJ45 interface)" and, in the overview, "With RS-485 communication bus interface and Modbus communication protocol". The 40-page manual prints "RS485 interface 5VDC/100mA". Location: PDF page 25 (printed page 22), section 5 Technical Specifications, Electrical Parameters table, Communication row; PDF page 4, Overview Printed as "Communication RS485(RJ45 interface)" and, in the overview, "With RS-485 communication bus interface and Modbus communication protocol". The 40-page manual prints "RS485 interface 5VDC/100mA". Location: PDF page 25 (printed page 22), section 5 Technical Specifications, Electrical Parameters table, Communication row; PDF page 4, Overview Official user manual · ACOPOWER HY-MPPT Series MPPT Solar Charge Controller User Manual (HY-MPPT10/20/30/40, V1.4)Official user manual · ACOPOWER HY-MPPT Series MPPT Solar Charge Controller User Manual (HY-MPPT10/20/30/40 and Tracer1206AN/2206AN, version 1.0) [1, 2] |
| Controller type | MPPTDocumented claim ConditionsPrinted as "Maximum Power Point Tracking (MPPT) controller in HY-MPPT series"; the 40-page manual's tables print HY-MPPT40 beside the Tracer AN models under its MPPT title. Location: PDF page 2, Important Safety Instructions Printed as "Maximum Power Point Tracking (MPPT) controller in HY-MPPT series"; the 40-page manual's tables print HY-MPPT40 beside the Tracer AN models under its MPPT title. Location: PDF page 2, Important Safety Instructions Official user manual · ACOPOWER HY-MPPT Series MPPT Solar Charge Controller User Manual (HY-MPPT10/20/30/40, V1.4)Official user manual · ACOPOWER HY-MPPT Series MPPT Solar Charge Controller User Manual (HY-MPPT10/20/30/40 and Tracer1206AN/2206AN, version 1.0) [1, 2] |
| Dimensions | 252 x 180 x 63 mmDocumented claim ConditionsThe Mechanical Parameters table prints "Dimension 228mmx164mmx55mm 252mmx180mmx63mm"; this is the second (HY-MPPT40) column. No length, width or height labels are printed, so the figures stay in the printed order. The 40-page manual (PDF page 29) prints the same figures in its fourth (HY-MPPT40) column. Location: PDF page 26 (printed page 23), section 5 Mechanical Parameters table, Dimension row, HY-MPPT40 column The Mechanical Parameters table prints "Dimension 228mmx164mmx55mm 252mmx180mmx63mm"; this is the second (HY-MPPT40) column. No length, width or height labels are printed, so the figures stay in the printed order. The 40-page manual (PDF page 29) prints the same figures in its fourth (HY-MPPT40) column. Location: PDF page 26 (printed page 23), section 5 Mechanical Parameters table, Dimension row, HY-MPPT40 column Official user manual · ACOPOWER HY-MPPT Series MPPT Solar Charge Controller User Manual (HY-MPPT10/20/30/40, V1.4)Official user manual · ACOPOWER HY-MPPT Series MPPT Solar Charge Controller User Manual (HY-MPPT10/20/30/40 and Tracer1206AN/2206AN, version 1.0) [1, 2] |
| Enclosure | IP30Documented claim ConditionsPrinted as "Enclosure IP30" in both ACOPOWER HY-MPPT manuals. Location: PDF page 25 (printed page 22), section 5 Technical Specifications, Environmental Parameters table, Enclosure row Printed as "Enclosure IP30" in both ACOPOWER HY-MPPT manuals. Location: PDF page 25 (printed page 22), section 5 Technical Specifications, Environmental Parameters table, Enclosure row Official user manual · ACOPOWER HY-MPPT Series MPPT Solar Charge Controller User Manual (HY-MPPT10/20/30/40, V1.4)Official user manual · ACOPOWER HY-MPPT Series MPPT Solar Charge Controller User Manual (HY-MPPT10/20/30/40 and Tracer1206AN/2206AN, version 1.0) [1, 2] |
| Grounding (manual) | common positive; the HY-MPPT series is a positive ground controllerNeeds confirmationACOPOWER's 36-page HY-MPPT Series manual (V1.4) prints "Grounding Common positive" and "The HY-MPPT series is a positive ground controller."; ACOPOWER's 40-page HY-MPPT manual (version 1.0, which also covers the Tracer1206AN/2206AN) prints "Grounding Common negative" in a row shared by every column, including the HY-MPPT columns. Neither manual is dated and they may describe different hardware revisions; check the unit's own label and manual before wiring. Both values are kept; neither is confirmed. ConditionsPrinted as "Grounding Common positive" in the section 5 table and "The HY-MPPT series is a positive ground controller. Any positive connection of solar, load or battery can be earth grounded as required." in the installation notes; the overview (PDF page 4) says "Based on common positive design". The 40-page manual prints common negative (kept below); the two manuals disagree. Location: PDF page 25 (printed page 22), section 5 Technical Specifications, Electrical Parameters table, Grounding row; PDF page 15 (printed page 12), installation note 4 Printed as "Grounding Common positive" in the section 5 table and "The HY-MPPT series is a positive ground controller. Any positive connection of solar, load or battery can be earth grounded as required." in the installation notes; the overview (PDF page 4) says "Based on common positive design". The 40-page manual prints common negative (kept below); the two manuals disagree. Location: PDF page 25 (printed page 22), section 5 Technical Specifications, Electrical Parameters table, Grounding row; PDF page 15 (printed page 12), installation note 4 |
| Installation clearances (manual) | at least 150mm of clearance above and belowDocumented claim ConditionsPrinted as "The controller requires at least 150mm of clearance above and below for proper air flow." in both ACOPOWER HY-MPPT manuals. Location: PDF page 14 (printed page 11), section 2.4 Mounting Printed as "The controller requires at least 150mm of clearance above and below for proper air flow." in both ACOPOWER HY-MPPT manuals. Location: PDF page 14 (printed page 11), section 2.4 Mounting Official user manual · ACOPOWER HY-MPPT Series MPPT Solar Charge Controller User Manual (HY-MPPT10/20/30/40, V1.4)Official user manual · ACOPOWER HY-MPPT Series MPPT Solar Charge Controller User Manual (HY-MPPT10/20/30/40 and Tracer1206AN/2206AN, version 1.0) [1, 2] |
| Load output current | 40 ADocumented claim ConditionsPrinted as "Rated discharge current 10A 20A 30A 40A" for the four HY-MPPT columns; this is the HY-MPPT40 column. The 40-page manual prints the same 40A in its sixth (HY-MPPT 40) column. Location: PDF page 25 (printed page 22), section 5 Technical Specifications, Electrical Parameters table, Rated discharge current row, HY-MPPT40 column Printed as "Rated discharge current 10A 20A 30A 40A" for the four HY-MPPT columns; this is the HY-MPPT40 column. The 40-page manual prints the same 40A in its sixth (HY-MPPT 40) column. Location: PDF page 25 (printed page 22), section 5 Technical Specifications, Electrical Parameters table, Rated discharge current row, HY-MPPT40 column Official user manual · ACOPOWER HY-MPPT Series MPPT Solar Charge Controller User Manual (HY-MPPT10/20/30/40, V1.4)Official user manual · ACOPOWER HY-MPPT Series MPPT Solar Charge Controller User Manual (HY-MPPT10/20/30/40 and Tracer1206AN/2206AN, version 1.0) [1, 2] |
| Maximum conversion efficiency | 98 %Documented claim ConditionsPrinted as "with maximum conversion efficiency of 98%" in the series features; the 40-page manual prints the same. Manufacturer claim, not an independent test. Location: PDF page 4 (printed page 1), Overview features Printed as "with maximum conversion efficiency of 98%" in the series features; the 40-page manual prints the same. Manufacturer claim, not an independent test. Location: PDF page 4 (printed page 1), Overview features Official user manual · ACOPOWER HY-MPPT Series MPPT Solar Charge Controller User Manual (HY-MPPT10/20/30/40, V1.4)Official user manual · ACOPOWER HY-MPPT Series MPPT Solar Charge Controller User Manual (HY-MPPT10/20/30/40 and Tracer1206AN/2206AN, version 1.0) [1, 2] |
| Maximum PV input power by battery voltage | 1,560 W at 12 V; 3,120 W at 24 VNeeds confirmationThe 36-page HY-MPPT Series manual (V1.4) prints a Max. PV Array Power of 1560W/12V 3120W/24V (it says the array must not exceed three times the rated charge power); the 40-page HY-MPPT manual (version 1.0) prints a recommended Max. PV Array Power of 780W/12V 1560W/24V (at most 1.5 times the rated charge power). The 36-page manual's value is recorded. ConditionsPrinted as "HY-MPPT40 40A 520W/12V 1040W/24V 1560W/12V 3120W/24V": Max. PV Array Power 1560W/12V 3120W/24V. The manual warns the controller is damaged when the array's actual operating power exceeds three times the rated charge power (1.5 times with reversed polarity). The section 5 table's "Max. PV input power" row prints the rated charge power figures instead. Location: PDF page 13 (printed page 10), section 2.2 PV array table, HY-MPPT40 row, Max. PV Array Power column Printed as "HY-MPPT40 40A 520W/12V 1040W/24V 1560W/12V 3120W/24V": Max. PV Array Power 1560W/12V 3120W/24V. The manual warns the controller is damaged when the array's actual operating power exceeds three times the rated charge power (1.5 times with reversed polarity). The section 5 table's "Max. PV input power" row prints the rated charge power figures instead. Location: PDF page 13 (printed page 10), section 2.2 PV array table, HY-MPPT40 row, Max. PV Array Power column |
| Maximum PV voltage | 100V at minimum operating environment temperature; 92V at 25℃ environment temperatureDocumented claim ConditionsPrinted as "Max. PV open circuit voltage 100V at minimum operating environment temperature 92V at 25℃ environment temperature", shared by the four HY-MPPT columns. The 40-page manual prints 100V (footnote: at minimum operating environment temperature) and 92V (footnote: at 25℃) across its four HY-MPPT columns; its Tracer AN columns print 60V and 46V instead. Location: PDF page 25 (printed page 22), section 5 Technical Specifications, Electrical Parameters table, Max. PV open circuit voltage row Printed as "Max. PV open circuit voltage 100V at minimum operating environment temperature 92V at 25℃ environment temperature", shared by the four HY-MPPT columns. The 40-page manual prints 100V (footnote: at minimum operating environment temperature) and 92V (footnote: at 25℃) across its four HY-MPPT columns; its Tracer AN columns print 60V and 46V instead. Location: PDF page 25 (printed page 22), section 5 Technical Specifications, Electrical Parameters table, Max. PV open circuit voltage row Official user manual · ACOPOWER HY-MPPT Series MPPT Solar Charge Controller User Manual (HY-MPPT10/20/30/40, V1.4)Official user manual · ACOPOWER HY-MPPT Series MPPT Solar Charge Controller User Manual (HY-MPPT10/20/30/40 and Tracer1206AN/2206AN, version 1.0) [1, 2] |
| MPPT tracking efficiency | ≥ 99.5%Documented claim ConditionsPrinted as "Advanced Maximum Power Point Tracking (MPPT) technology, with efficiency no less than 99.5%"; the 40-page manual prints "Advanced MPPT technology, with efficiency no less than 99.5%". Location: PDF page 4 (printed page 1), Overview features Printed as "Advanced Maximum Power Point Tracking (MPPT) technology, with efficiency no less than 99.5%"; the 40-page manual prints "Advanced MPPT technology, with efficiency no less than 99.5%". Location: PDF page 4 (printed page 1), Overview features Official user manual · ACOPOWER HY-MPPT Series MPPT Solar Charge Controller User Manual (HY-MPPT10/20/30/40, V1.4)Official user manual · ACOPOWER HY-MPPT Series MPPT Solar Charge Controller User Manual (HY-MPPT10/20/30/40 and Tracer1206AN/2206AN, version 1.0) [1, 2] |
| MPPT voltage range | VBAT+2V~72VDocumented claim ConditionsPrinted as "MPP Voltage range VBAT+2V~72V" (battery voltage plus 2 V up to 72 V), shared by the four HY-MPPT columns; the 40-page manual prints "(Battery voltage +2V)~ 72V" across its HY-MPPT columns. Location: PDF page 25 (printed page 22), section 5 Technical Specifications, Electrical Parameters table, MPP Voltage range row Printed as "MPP Voltage range VBAT+2V~72V" (battery voltage plus 2 V up to 72 V), shared by the four HY-MPPT columns; the 40-page manual prints "(Battery voltage +2V)~ 72V" across its HY-MPPT columns. Location: PDF page 25 (printed page 22), section 5 Technical Specifications, Electrical Parameters table, MPP Voltage range row Official user manual · ACOPOWER HY-MPPT Series MPPT Solar Charge Controller User Manual (HY-MPPT10/20/30/40, V1.4)Official user manual · ACOPOWER HY-MPPT Series MPPT Solar Charge Controller User Manual (HY-MPPT10/20/30/40 and Tracer1206AN/2206AN, version 1.0) [1, 2] |
| Operating temperature | -25 to 45 °C-13 to 113 °F convertedNeeds confirmationThe 36-page HY-MPPT Series manual (V1.4) prints "-25℃~+45℃" (derate beyond the permitted range); the 40-page HY-MPPT manual (version 1.0) prints "-25℃~+50℃(100% input and output)". The 36-page manual's value is recorded. ConditionsPrinted as "Working environment temperature range* -25℃~+45℃", with the footnote "Please operate controller at permitted ambient temperature. If over permissible range, please derate capacity in service." Location: PDF page 25 (printed page 22), section 5 Technical Specifications, Environmental Parameters table, Working environment temperature range row Printed as "Working environment temperature range* -25℃~+45℃", with the footnote "Please operate controller at permitted ambient temperature. If over permissible range, please derate capacity in service." Location: PDF page 25 (printed page 22), section 5 Technical Specifications, Environmental Parameters table, Working environment temperature range row |
| PV input current / MPPT | 40 ADocumented claim ConditionsPrinted as "HY-MPPT40 40A 16/6" (Max. PV input current, then Max. PV wire size in mm2/AWG). The 40-page manual (PDF page 13) prints the same 40A. Location: PDF pages 13 and 14 (printed pages 10 and 11), section 2.3 PV Wire Size table, HY-MPPT40 row Printed as "HY-MPPT40 40A 16/6" (Max. PV input current, then Max. PV wire size in mm2/AWG). The 40-page manual (PDF page 13) prints the same 40A. Location: PDF pages 13 and 14 (printed pages 10 and 11), section 2.3 PV Wire Size table, HY-MPPT40 row Official user manual · ACOPOWER HY-MPPT Series MPPT Solar Charge Controller User Manual (HY-MPPT10/20/30/40, V1.4)Official user manual · ACOPOWER HY-MPPT Series MPPT Solar Charge Controller User Manual (HY-MPPT10/20/30/40 and Tracer1206AN/2206AN, version 1.0) [1, 2] |
| Rated charge power | 520W/12V 1040W/24VDocumented claim ConditionsPrinted as "HY-MPPT40 40A 520W/12V 1040W/24V 1560W/12V 3120W/24V" (Rated Charge Current, Rated Charge Power, Max. PV Array Power). The section 5 Electrical Parameters table of both manuals prints the same 520W/12V 1040W/24V in a row labeled "Max. PV input power". The 40-page manual's PV array table prints the same rated charge power. Location: PDF page 13 (printed page 10), section 2.2 PV array table, HY-MPPT40 row, Rated Charge Power column Printed as "HY-MPPT40 40A 520W/12V 1040W/24V 1560W/12V 3120W/24V" (Rated Charge Current, Rated Charge Power, Max. PV Array Power). The section 5 Electrical Parameters table of both manuals prints the same 520W/12V 1040W/24V in a row labeled "Max. PV input power". The 40-page manual's PV array table prints the same rated charge power. Location: PDF page 13 (printed page 10), section 2.2 PV array table, HY-MPPT40 row, Rated Charge Power column Official user manual · ACOPOWER HY-MPPT Series MPPT Solar Charge Controller User Manual (HY-MPPT10/20/30/40, V1.4)Official user manual · ACOPOWER HY-MPPT Series MPPT Solar Charge Controller User Manual (HY-MPPT10/20/30/40 and Tracer1206AN/2206AN, version 1.0) [1, 2] |
| Self-consumption | ≤20mA(12V); ≤16mA(24V)Needs confirmationThe 36-page HY-MPPT Series manual (V1.4) prints "≤20mA(12V); ≤16mA(24V)"; the 40-page HY-MPPT manual (version 1.0) prints "≤12mA". The 36-page manual's value is recorded. ConditionsPrinted as "Self-consumption ≤20mA(12V); ≤16mA(24V)", shared by the four HY-MPPT columns. Location: PDF page 25 (printed page 22), section 5 Technical Specifications, Electrical Parameters table, Self-consumption row Printed as "Self-consumption ≤20mA(12V); ≤16mA(24V)", shared by the four HY-MPPT columns. Location: PDF page 25 (printed page 22), section 5 Technical Specifications, Electrical Parameters table, Self-consumption row |
| Storage temperature | -35 to 80 °C-31 to 176 °F convertedNeeds confirmationThe 36-page HY-MPPT Series manual (V1.4) prints "-35℃~+80℃"; the 40-page HY-MPPT manual (version 1.0) prints "-20℃~+70℃". The 36-page manual's value is recorded. ConditionsPrinted as "Storage temperature range -35℃~+80℃". Location: PDF page 25 (printed page 22), section 5 Technical Specifications, Environmental Parameters table, Storage temperature range row Printed as "Storage temperature range -35℃~+80℃". Location: PDF page 25 (printed page 22), section 5 Technical Specifications, Environmental Parameters table, Storage temperature range row |
| Weight | 1.9 kg4.2 lb convertedNeeds confirmationThe 36-page HY-MPPT Series manual (V1.4) prints 1.9kg; the 40-page HY-MPPT manual (version 1.0) prints 1.65kg. The 36-page manual's value is recorded. ConditionsThe Mechanical Parameters table prints "Weight 1.2kg 1.9kg"; this is the second (HY-MPPT40) column. Location: PDF page 26 (printed page 23), section 5 Mechanical Parameters table, Weight row, HY-MPPT40 column The Mechanical Parameters table prints "Weight 1.2kg 1.9kg"; this is the second (HY-MPPT40) column. Location: PDF page 26 (printed page 23), section 5 Mechanical Parameters table, Weight row, HY-MPPT40 column |
Warranty
Certificate records
No records documented.
Sources and revisions
- ACOPOWER HY-MPPT Series MPPT Solar Charge Controller User Manual (HY-MPPT10/20/30/40, V1.4)Official user manual · Revision V1.4 · Checked https://cdn.shopify.com/s/files/1/0095/7431/8146/files/HY-MPPT2-20-30-40-4.pdf?3097
- ACOPOWER HY-MPPT Series MPPT Solar Charge Controller User Manual (HY-MPPT10/20/30/40 and Tracer1206AN/2206AN, version 1.0)Official user manual · Revision 1.0 · Checked https://cdn.shopify.com/s/files/1/0095/7431/8146/files/acopower_MPPT10-40A_Tracer-AN-SMS-EL-V1.0_3.pdf?3299