About brandYoshino Power sells solid-state portable power stations, expansion batteries, solar panels and accessories from its own US store, whose metadata gives Rancho Cucamonga, California as its location.
SKU detail
locator: products[].variants[].sku for yoshino-exb1-solid-state-expansion-battery-for-b4000-sst-2562wh
conditions: Yoshino Power's ordering SKU for the unit alone, printed as "sku":"EXB1" in the yoshinopower.com listing captured on September 26, 2026.
Printed as "Capacity 2562Wh 47.45V, 54Ah". The specification page is laid out as a grid of labeled cells; text extraction runs the cells together, so each value was assigned to its label by its position on the page (read from the PDF's text coordinates).
Printed as "12-60VDC/20A Max 1200W Max" under Solar Input. The specification page is laid out as a grid of labeled cells; text extraction runs the cells together, so each value was assigned to its label by its position on the page (read from the PDF's text coordinates).
Charged Reviews classified this product from the documents it is based on. It is our own grouping, not a manufacturer claim.
Printed as "The Master Power Station can be connected with an Expansion Battery (EXB1) to expand capacity". Classified as Portable expansion from the maker's own words for this model (PM decision, October 13, 2026: an expansion or extra battery for a power station is Portable expansion).
Printed as "32 to 131°F / 0 to 55°C" beside Charging Temperature. The specification page is laid out as a grid of labeled cells; text extraction runs the cells together, so each value was assigned to its label by its position on the page (read from the PDF's text coordinates).
Where: Specifications, TEMPERATURE / HUMIDITY, Charging Temperature
Printed as "-0.4 to 140°F / -18 to 60°C" beside Discharging Temperature. The specification page is laid out as a grid of labeled cells; text extraction runs the cells together, so each value was assigned to its label by its position on the page (read from the PDF's text coordinates).
Where: Specifications, TEMPERATURE / HUMIDITY, Discharging Temperature
33.88 L* (Calculated enclosure volume: W × H × D in mm ÷ 1,000,000)W: 260 × H: 240 × L: 543 mm / W: 10.2 × H: 9.45 × L: 21.4 in20.2 kg / 44.5 lb0.08 kWh/L* (Rated or usable capacity shown on this card ÷ enclosure volume)
Evidence score
14/100Missing details40% documented
The Evidence score uses the priorities you choose. It counts published documents, such as certificates and warranty terms, and it compares a documented figure with the best documented figure of the same kind. It does not count owner reviews, and it is not a verdict on product quality or on how many people have reviewed it. A low score can mean little is documented, or that a documented figure is below the best of its kind. Undisclosed data scores 0.
Missing details. This number counts only the evidence recorded so far. The source review for this product is not finished, or the maker has not disclosed enough, so the number can only go up.
Missing for this product: Certificates evidence needed; Warranty energy disclosure evidence needed; Cell model disclosure evidence needed.
48 V · Portable expansion · Expansion · Rated capacity
The warranty term and the lifetime energy are each scored against the best documented value for an expansion battery: a value earns its share of that best, times the weight. A documented value always earns points; an undisclosed one earns 0.
Research pending, 0 points: Certificates, Warranty energy disclosure, Cell model disclosure.
Computed from public specifications and evidence records. Warranty duration is not service quality; certificate evidence points are not a safety rating. Compatibility and installation limits still apply.
Captured by scripts/prepare-brand-sweep-sep21.mjs on 2026-09-26.
Location: Specifications (PDF page 18)
Retrieved Sep 26, 2026
Yoshino Power's user manual for the EXB1, linked from the yoshinopower.com Downloads page and captured on September 26, 2026. Its Specifications page prints capacity, battery type, cycle life, outputs, inputs, weight, dimensions, warranty and temperatures. The specification page is laid out as a grid of labeled cells; text extraction runs the cells together, so each value was assigned to its label by its position on the page (read from the PDF's text coordinates). The date is read from the file name. Manufacturer claims, not independent tests.
Archived copies
Archived copy of a document published by Yoshino Power. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Captured by scripts/prepare-brand-sweep-sep21.mjs on 2026-09-26.
Location: Feature copy; Specifications; product media
Retrieved Sep 26, 2026
Yoshino Power's own US product page for the EXB1, captured on September 26, 2026. It repeats most of the manual's specification figures, adds feature copy and publishes the product photographs. Where it differs from the user manual the manual is recorded as the fact and the page as an alternative. Manufacturer claims, not independent tests.
Captured by scripts/prepare-brand-sweep-sep21.mjs on 2026-09-26.
Location: User Manuals
Retrieved Sep 26, 2026
Yoshino Power's own Downloads page, captured on September 26, 2026. Kept as the page that links each US user manual cited here; no specification is read from it.
Yoshino EXB1 User Manual (US, file dated 20250409)
Archived copy of a document published by Yoshino Power. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
No sourced accessories or replacement parts listed yet.
Model history
Model identity
Model
EXB1
Manufacturer SKU EXB1 · US market
No historical observations recorded yet.
Other recorded fields
Field
Value
Conditions
Source
Evidence breakdown
method version: 0.21-personal
documented pct: 40
basis: nominal
missing:
Certificates evidence needed
Warranty energy disclosure evidence needed
Cell model disclosure evidence needed
criteria:
key: certificateEvidence
label: Certificates
value: 0
unit: evidence points
shown: Research pending
shown detail: Unknown
state: pending
points: 0
ceiling: 45
weight: 45
share: 0
covered: no
missing: yes
folded: yes
reason: Unknown
reason text: Unknown
note: No qualifying applicable evidence recorded. This is not proof that certification is absent. Applies: UL 1973; CEC not assessed without a recorded parent system; UL 9540 not assessed without a recorded parent system.