Weight140 kg / 309 lb converted
Nominal energy13.5 kWh
Continuous output7 kW

2 specs not documented yet: chemistry, usable energyHelp fill in ›

All specifications

Identity

BrandTesla · Website
ModelPowerwall+
MarketUS
Manufacturer SKU1850000-xx-y
About brandPowerwall home storage and integrated energy equipment.
SKU detail
locator: Technical specifications table
conditions: Printed as "Powerwall+ Model Number 1850000-xx-y". The datasheet separately prints a "Solar Assembly Model Number 1538000-xx-y" for the integrated solar inverter assembly that ships as part of the same unit; that is a component model number, not an alternate SKU for the Powerwall+ product, and is recorded in identity_notes rather than merged here. See alternatives for the warranty document's differing suffix.
Sources: [1]
alternatives:
state: documented
value: 1850000-xx-x
locator: Rev. 2.6 page 1, Applies to table, Powerwall+ row
printed:
Powerwall+ Part Number 1850000-xx-x
conditions: Printed under the heading "Powerwall+" using an "-xx-x" suffix rather than the datasheet's "-xx-y" suffix; otherwise the same part-number family.
Sources: [2]
FieldValueConditionsSource
ChemistryUnknown
No chemistry statement is printed in the Powerwall+ datasheet; not assumed from the Powerwall 2 datasheet's lithium-ion statement, since they are different products.
No source on record
Weight140 kg / 309 lb converted
Printed as "Total Weight 140 kg (310 lb) 9"; the datasheet separately prints Battery Assembly 118 kg (261 lb) and Solar Assembly 22 kg (49 lb), and footnote 9 says the total excludes the mounting bracket (an additional 9 kg / 20 lb).
Where: Mechanical specifications table
[1]
DimensionsW 1,596 × H 755 × D 160 mm / W 62.83 × H 29.7 × D 6.3 in converted
Printed as "Dimensions 1596 x 755 x 160 mm (62.8 x 29.7 x 6.3 in)".
Where: Mechanical specifications table
[1]
Battery format
Wall / floor
Site classificationBased onOfficial datasheet
Details

Charged Reviews classified this product from the documents it is based on. It is our own grouping, not a manufacturer claim.

Printed as "Mounting Options Floor or wall mount". Classified as Wall / floor from the maker's own words for this model (wall or floor mounting, the catalog's combined Wall / floor value).

Official datasheet: Tesla Powerwall+ Datasheet 2024 (energylibrary.tesla.com)

Location: Tesla Powerwall+ Datasheet 2024 (energylibrary.tesla.com), mechanical specifications, page 3

CommunicationsWi-Fi; Ethernet; Cellular (LTE/4G)
Printed as "Internet Connectivity Wi-Fi, Ethernet, Cellular (LTE/4G) 7"; footnote 7 says cellular connectivity is subject to network service coverage.
Where: Technical specifications table
[1]
Enclosure ratingType 3R; IP56 (Battery Assembly Wiring Compartment); IP67 (Battery & Power Electronics); IP55 (Solar Assembly Wiring Compartment)
Printed as "Enclosure Type Type 3R", "Solar Assembly Ingress Rating IP55 (Wiring Compartment)" and "Battery Assembly Ingress Rating IP56 (Wiring Compartment) IP67 (Battery & Power Electronics)".
Where: Environmental specifications table
[1]
Load start a LRA118 A LRA
Upper end of the printed range "Load Start Capability 98 - 118 A LRA 3"; footnote 3 says load start capability may vary.
Where: Technical specifications table
[1]
Apparent power5.8 kVA
Printed as "Maximum Continuous Power On-Grid 7.6 kVA with sun / 5.8 kVA no sun 1,2"; the no-sun figure is recorded as the battery-only apparent power rating.
Where: Technical specifications table
[1]
Nominal energy13.5 kWh
Printed as "Nominal Battery Energy 13.5 kWh 1"; footnote 1 states values are for 25 C (77 F), 3.3 kW charge/discharge power.
Where: Technical specifications table
[1]
Certification claimsUL 1699B; UL 1741; UL 3741; UL 1741 SA; UL 1741 SB; UL 1998 (US); IEEE 1547-2018; IEEE 1547.1; UL 1642; UL 1741 PCS; UL 1973; UL 9540; UN 38.3; FCC Part 15 Class B; RoHS Directive 2011/65/EU; AC156; IEEE 693-2005
Manufacturer claim recorded exactly as printed across the separate PV Certifications and Battery Energy Storage System Certifications rows, plus the Emissions, Environmental and Seismic rows. Standards printed in both the PV and BESS lists (UL 1741, UL 1741 SA, UL 1741 SB, IEEE 1547-2018, IEEE 1547.1) are listed once.
Where: Compliance information tables
[1]
Continuous output7 kW
Printed as "Maximum Continuous Power Off-Grid 9.6 kW with sun / 7 kW no sun"; the figure printed for operation without sun (7 kW) is recorded here and the figure with sun (9.6 kW) is kept beside it. The on-grid rating is printed separately in apparent power (kVA).
Where: Technical specifications table
Sources
9.6 kW

Printed as "9.6 kW with sun" in the same Maximum Continuous Power Off-Grid row.

[1]
[1]
Storage temperature-20C to 30C (-4F to 86F) °C/°F
Printed as the storage condition range; up to 95% RH non-condensing.
Where: Environmental specifications table
[1]
Continuous AC output40 A
Printed as "Maximum Continuous Current Off-Grid 40 A output"; on-grid current is printed separately as 32 A.
Where: Technical specifications table
[1]
Operating temperature-20C to 50C (-4F to 122F) °C/°F
Printed as the operating temperature range with Fahrenheit equivalent; footnote 8 says performance may be derated below 10C (50F) or above 43C (109F).
Where: Environmental specifications table
[1]
Round trip efficiency90 %
Printed as "Round Trip Efficiency 90% 1,6"; footnote 6 says AC to battery to AC, at beginning of life.
Where: Technical specifications table
[1]

Owner reviews

No owner reviews yet
Write a review

Sellers

No listed sellers in this data.

Price history

No seller price history.

Quick reference sheet

Basic specs
13.5 kWhDischarge 7 kWCharge Unknown
$ / rated kWh
Unavailable
Warranty
10 yearsSee terms
Lifetime production
37.8 MWhWarranty limit
Size
192.8 L* (Calculated enclosure volume: W × H × D in mm ÷ 1,000,000)W: 1,596 × H: 755 × D: 160 mm / W: 62.83 × H: 29.7 × D: 6.3 in140 kg / 309 lb0.07 kWh/L* (Rated or usable capacity shown on this card ÷ enclosure volume)

Evidence score

58/100Missing details65% documented

The Evidence score uses the priorities you choose. It counts published documents, such as certificates and warranty terms, and it compares a documented figure with the best documented figure of the same kind. It does not count owner reviews, and it is not a verdict on product quality or on how many people have reviewed it. A low score can mean little is documented, or that a documented figure is below the best of its kind. Undisclosed data scores 0.

Missing details. This number counts only the evidence recorded so far. The source review for this product is not finished, or the maker has not disclosed enough, so the number can only go up.

Missing for this product: Warranty energy disclosure evidence needed; Lifetime / capacity evidence needed; Cell model disclosure evidence needed.

AC-coupled · Wall / floor · Usable capacity

The warranty term and the lifetime energy are each scored against the best documented value for a home storage battery: a value earns its share of that best, times the weight. A documented value always earns points; an undisclosed one earns 0.

CertificatesCEC · UL 1699B +15CEC listed45 / 45

100 evidence points · 45% weight

CEC listing: full credit for the certificate criterion. Exact model found in the dated CEC equipment list. This is not a safety certification or system approval. Applies: CEC; UL 9540; UL 1973.

100 / 100 × 45 = 45 points.

[3] [4]

Warranty term10 years13.33 / 20

10 years · 20% weight

10 of 15 years, the best documented for a home storage battery (printed by the maker): Blue Ion LX battery energy storage system (125 kW / 128 kWh)

Datasheet prints "Warranty 10 years" after the Protections row; the warranty document's Ten Year Limited Warranty section covers Powerwall+ by part number.

66.7 / 100 × 20 = 13.33 points.

[1] [2]

Warranty energy disclosure37.8 MWh · not confirmed0 / 10

0 evidence points · 10% weight

No qualifying quantified warranty energy recorded. This is an evidence gap, not a performance judgment.

0 / 100 × 10 = 0 points.

[2]

Lifetime / capacity37.8 MWh · not confirmed0 / 20

No qualifying figure · 20% weight

Lifetime amount or capacity needs confirmation. No lifetime-production bonus.

A value is on file but is not counted: it carries a warning or is not confirmed.

[2]

Research pending, 0 points: Cell model disclosure.

Computed from public specifications and evidence records. Warranty duration is not service quality; certificate evidence points are not a safety rating. Compatibility and installation limits still apply.

Certificates

What this shows: what each record says and how far it reaches. It does not mean the product is approved.
UL 1699Bmanufacturer claimpresent at observation[1]
Scope
equipment listing
Covered models
Powerwall+
Limitations
Printed exactly as shown in the Compliance Information tables of Tesla's Powerwall+ datasheet: "PV Certifications UL 1699B, UL 1741, UL 3741, UL 1741 SA, UL 1741 SB, UL 1998 (US), IEEE 1547-2018, IEEE 1547.1". No certificate number, issuer or scope is printed beyond this row; no issuer directory was checked.
Record detail
Issued: Not stated
Valid from: Not stated
Expiry: Not stated
Not checked
Source
[1]
UL 1741manufacturer claimpresent at observation[1]
Scope
equipment listing
Covered models
Powerwall+
Limitations
Printed exactly as shown in the Compliance Information tables of Tesla's Powerwall+ datasheet: "PV Certifications UL 1699B, UL 1741, UL 3741, UL 1741 SA, UL 1741 SB, UL 1998 (US), IEEE 1547-2018, IEEE 1547.1". No certificate number, issuer or scope is printed beyond this row; no issuer directory was checked.
Record detail
Issued: Not stated
Valid from: Not stated
Expiry: Not stated
Not checked
Source
[1]
UL 1973manufacturer claimpresent at observation[1]
Scope
equipment listing
Covered models
Powerwall+
Limitations
Printed exactly as shown in the Compliance Information tables of Tesla's Powerwall+ datasheet: "Battery Energy Storage System Certifications UL 1642, UL 1741, UL 1741 PCS, UL 1741 SA, UL 1741 SB, UL 1973, UL 9540, IEEE 1547-2018, IEEE 1547.1, UN 38.3". No certificate number, issuer or scope is printed beyond this row; no issuer directory was checked.
Record detail
Issued: Not stated
Valid from: Not stated
Expiry: Not stated
Not checked
Source
[1]
UL 9540manufacturer claimpresent at observation[1]
Scope
equipment listing
Covered models
Powerwall+
Limitations
Printed exactly as shown in the Compliance Information tables of Tesla's Powerwall+ datasheet: "Battery Energy Storage System Certifications UL 1642, UL 1741, UL 1741 PCS, UL 1741 SA, UL 1741 SB, UL 1973, UL 9540, IEEE 1547-2018, IEEE 1547.1, UN 38.3". No certificate number, issuer or scope is printed beyond this row; no issuer directory was checked.
Record detail
Issued: Not stated
Valid from: Not stated
Expiry: Not stated
Not checked
Edition as printed: Not printed
Source
[1]
UN 38.3manufacturer claimpresent at observation[1]
Scope
equipment listing
Covered models
Powerwall+
Limitations
Printed exactly as shown in the Compliance Information tables of Tesla's Powerwall+ datasheet: "Battery Energy Storage System Certifications UL 1642, UL 1741, UL 1741 PCS, UL 1741 SA, UL 1741 SB, UL 1973, UL 9540, IEEE 1547-2018, IEEE 1547.1, UN 38.3". No certificate number, issuer or scope is printed beyond this row; no issuer directory was checked.
Record detail
Issued: Not stated
Valid from: Not stated
Expiry: Not stated
Not checked
Source
[1]
FCC Part 15 Class Bmanufacturer claimpresent at observation[1]
Scope
unresolved document set
Covered models
Powerwall+
Limitations
Printed exactly as shown in the Compliance Information tables of Tesla's Powerwall+ datasheet: "Emissions FCC Part 15 Class B". No certificate number, issuer or scope is printed beyond this row; no issuer directory was checked.
Record detail
Issued: Not stated
Valid from: Not stated
Expiry: Not stated
Not checked
Source
[1]
RoHS Directive 2011/65/EUmanufacturer claimpresent at observation[1]
Scope
unresolved document set
Covered models
Powerwall+
Limitations
Printed exactly as shown in the Compliance Information tables of Tesla's Powerwall+ datasheet: "Environmental RoHS Directive 2011/65/EU". No certificate number, issuer or scope is printed beyond this row; no issuer directory was checked.
Record detail
Issued: Not stated
Valid from: Not stated
Expiry: Not stated
Not checked
Source
[1]
AC156manufacturer claimpresent at observation[1]
Scope
unresolved document set
Covered models
Powerwall+
Limitations
Printed exactly as shown in the Compliance Information tables of Tesla's Powerwall+ datasheet: "Seismic AC156, IEEE 693-2005 (high)". No certificate number, issuer or scope is printed beyond this row; no issuer directory was checked.
Record detail
Issued: Not stated
Valid from: Not stated
Expiry: Not stated
Not checked
Source
[1]
IEEE 693-2005manufacturer claimpresent at observation[1]
Scope
unresolved document set
Covered models
Powerwall+
Limitations
Printed exactly as shown in the Compliance Information tables of Tesla's Powerwall+ datasheet: "Seismic AC156, IEEE 693-2005 (high)". No certificate number, issuer or scope is printed beyond this row; no issuer directory was checked.
Record detail
Issued: Not stated
Valid from: Not stated
Expiry: Not stated
Not checked
Source
[1]
UL 3741manufacturer claimpresent at observation[1]
Scope
equipment listing
Covered models
Powerwall+
Limitations
Printed exactly as shown in the Compliance Information tables of Tesla's Powerwall+ datasheet: "PV Certifications UL 1699B, UL 1741, UL 3741, UL 1741 SA, UL 1741 SB, UL 1998 (US), IEEE 1547-2018, IEEE 1547.1". No certificate number, issuer or scope is printed beyond this row; no issuer directory was checked.
Record detail
Issued: Not stated
Valid from: Not stated
Expiry: Not stated
Not checked
Source
[1]
UL 1741 SAmanufacturer claimpresent at observation[1]
Scope
equipment listing
Covered models
Powerwall+
Limitations
Printed exactly as shown in the Compliance Information tables of Tesla's Powerwall+ datasheet: "PV Certifications UL 1699B, UL 1741, UL 3741, UL 1741 SA, UL 1741 SB, UL 1998 (US), IEEE 1547-2018, IEEE 1547.1". No certificate number, issuer or scope is printed beyond this row; no issuer directory was checked.
Record detail
Issued: Not stated
Valid from: Not stated
Expiry: Not stated
Not checked
Source
[1]
UL 1741 SBmanufacturer claimpresent at observation[1]
Scope
equipment listing
Covered models
Powerwall+
Limitations
Printed exactly as shown in the Compliance Information tables of Tesla's Powerwall+ datasheet: "PV Certifications UL 1699B, UL 1741, UL 3741, UL 1741 SA, UL 1741 SB, UL 1998 (US), IEEE 1547-2018, IEEE 1547.1". No certificate number, issuer or scope is printed beyond this row; no issuer directory was checked.
Record detail
Issued: Not stated
Valid from: Not stated
Expiry: Not stated
Not checked
Source
[1]
UL 1998 (US)manufacturer claimpresent at observation[1]
Scope
equipment listing
Covered models
Powerwall+
Limitations
Printed exactly as shown in the Compliance Information tables of Tesla's Powerwall+ datasheet: "PV Certifications UL 1699B, UL 1741, UL 3741, UL 1741 SA, UL 1741 SB, UL 1998 (US), IEEE 1547-2018, IEEE 1547.1". No certificate number, issuer or scope is printed beyond this row; no issuer directory was checked.
Record detail
Issued: Not stated
Valid from: Not stated
Expiry: Not stated
Not checked
Source
[1]
IEEE 1547-2018manufacturer claimpresent at observation[1]
Scope
equipment listing
Covered models
Powerwall+
Limitations
Printed exactly as shown in the Compliance Information tables of Tesla's Powerwall+ datasheet: "PV Certifications UL 1699B, UL 1741, UL 3741, UL 1741 SA, UL 1741 SB, UL 1998 (US), IEEE 1547-2018, IEEE 1547.1". No certificate number, issuer or scope is printed beyond this row; no issuer directory was checked.
Record detail
Issued: Not stated
Valid from: Not stated
Expiry: Not stated
Not checked
Source
[1]
IEEE 1547.1manufacturer claimpresent at observation[1]
Scope
equipment listing
Covered models
Powerwall+
Limitations
Printed exactly as shown in the Compliance Information tables of Tesla's Powerwall+ datasheet: "PV Certifications UL 1699B, UL 1741, UL 3741, UL 1741 SA, UL 1741 SB, UL 1998 (US), IEEE 1547-2018, IEEE 1547.1". No certificate number, issuer or scope is printed beyond this row; no issuer directory was checked.
Record detail
Issued: Not stated
Valid from: Not stated
Expiry: Not stated
Not checked
Source
[1]
UL 1642manufacturer claimpresent at observation[1]
Scope
equipment listing
Covered models
Powerwall+
Limitations
Printed exactly as shown in the Compliance Information tables of Tesla's Powerwall+ datasheet: "Battery Energy Storage System Certifications UL 1642, UL 1741, UL 1741 PCS, UL 1741 SA, UL 1741 SB, UL 1973, UL 9540, IEEE 1547-2018, IEEE 1547.1, UN 38.3". No certificate number, issuer or scope is printed beyond this row; no issuer directory was checked.
Record detail
Issued: Not stated
Valid from: Not stated
Expiry: Not stated
Not checked
Source
[1]
UL 1741 PCSmanufacturer claimpresent at observation[1]
Scope
equipment listing
Covered models
Powerwall+
Limitations
Printed exactly as shown in the Compliance Information tables of Tesla's Powerwall+ datasheet: "Battery Energy Storage System Certifications UL 1642, UL 1741, UL 1741 PCS, UL 1741 SA, UL 1741 SB, UL 1973, UL 9540, IEEE 1547-2018, IEEE 1547.1, UN 38.3". No certificate number, issuer or scope is printed beyond this row; no issuer directory was checked.
Record detail
Issued: Not stated
Valid from: Not stated
Expiry: Not stated
Not checked
Source
[1]
CECauthority listing reportedlisted as of snapshot[3]
Scope
equipment listing
Covered models
1850000-xx-y
Limitations
Model 1850000-xx-y listed on the California Energy Commission Energy Storage System List (data unchanged since October 1, 2026; downloaded October 11, 2026) under Tesla Inc. (brand Powerwall +), as "1850000-XX-Y", CEC listing date 2021-05-03. The list prints "1850000-XX-Y"; the record's manufacturer SKU "1850000-xx-y" differs only in letter case. This is an equipment listing, not UL certification or complete-system approval.
Record detail
Issued: Not stated
Valid from: May 3, 2021
Expiry: Not stated
Issuer checked: Oct 11, 2026
Source
[3]
UL 9540authority listing reportedlisted as of snapshot[4]
Scope
equipment listing
Covered models
1850000-xx-y
Limitations
Listed on the California Energy Commission Energy Storage System List (data unchanged since October 21, 2026; downloaded October 23, 2026) as Tesla Inc. "1850000-XX-Y": UL 9540, certifying entity TUV Rheinland of North America, certificate date 2023-04-06, Ed. 2 : 2020, CEC listing date 2021-05-03. A state equipment list entry, not the certification body's own record.
Record detail
Issued: Not stated
Valid from: Apr 6, 2023
Expiry: Not stated
Issuer checked: Oct 23, 2026
Edition as printed: Ed. 2 : 2020
Source
[4]

Warranty

FieldValueConditionsSource
TerritoryUnited States of America
Printed as "purchased from Tesla or a Tesla certified installer in the United States of America" and "installed in the United States of America".
Where: Rev. 2.6 page 3, What Products are Covered
[2]
Start basisinitial installation date
Printed as "free from defects for ten years following its initial installation date".
Where: Rev. 2.6 page 1
[2]
Retention70 %
Printed as "70% at 10 years following initial installation date" for both listed application rows.
Where: Rev. 2.6 page 1, Energy Retention table
[2]
Warranty term10 years
Datasheet prints "Warranty 10 years" after the Protections row; the warranty document's Ten Year Limited Warranty section covers Powerwall+ by part number.
Where: Datasheet Technical specifications table; warranty Rev. 2.6 page 1
[1] [2]
Warranted throughput37.8 MWh
Printed as "37.8 MWh of aggregate throughput5", applying only to applications outside solar self-consumption, time-based control and backup, which instead get unlimited cycles.
Where: Rev. 2.6 page 1, Operating Limitation column and footnote 5
[2]

Recalls / legal notices

No recalls on file. All notices · Report a notice

This register is incomplete. A missing notice does not establish that a product has no recalls.

Documents

  • Datasheets

  • Tesla Powerwall+ Datasheet 2024 (energylibrary.tesla.com)Official · Tesla, Inc. · Official datasheet · PDF
    Certificate & compliance claims (17)
    UL 1699BManufacturer claim · equipment listingClaimedListed when checked

    Printed exactly as shown in the Compliance Information tables of Tesla's Powerwall+ datasheet: "PV Certifications UL 1699B, UL 1741, UL 3741, UL 1741 SA, UL 1741 SB, UL 1998 (US), IEEE 1547-2018, IEEE 1547.1". No certificate number, issuer or scope is printed beyond this row; no issuer directory was checked.

    Manufacturer document

    Official datasheet: Tesla Powerwall+ Datasheet 2024 (energylibrary.tesla.com)
    UL 1741Manufacturer claim · equipment listingClaimedListed when checked

    Printed exactly as shown in the Compliance Information tables of Tesla's Powerwall+ datasheet: "PV Certifications UL 1699B, UL 1741, UL 3741, UL 1741 SA, UL 1741 SB, UL 1998 (US), IEEE 1547-2018, IEEE 1547.1". No certificate number, issuer or scope is printed beyond this row; no issuer directory was checked.

    Manufacturer document

    Official datasheet: Tesla Powerwall+ Datasheet 2024 (energylibrary.tesla.com)
    UL 3741Manufacturer claim · equipment listingClaimedListed when checked

    Printed exactly as shown in the Compliance Information tables of Tesla's Powerwall+ datasheet: "PV Certifications UL 1699B, UL 1741, UL 3741, UL 1741 SA, UL 1741 SB, UL 1998 (US), IEEE 1547-2018, IEEE 1547.1". No certificate number, issuer or scope is printed beyond this row; no issuer directory was checked.

    Manufacturer document

    Official datasheet: Tesla Powerwall+ Datasheet 2024 (energylibrary.tesla.com)
    UL 1741 SAManufacturer claim · equipment listingClaimedListed when checked

    Printed exactly as shown in the Compliance Information tables of Tesla's Powerwall+ datasheet: "PV Certifications UL 1699B, UL 1741, UL 3741, UL 1741 SA, UL 1741 SB, UL 1998 (US), IEEE 1547-2018, IEEE 1547.1". No certificate number, issuer or scope is printed beyond this row; no issuer directory was checked.

    Manufacturer document

    Official datasheet: Tesla Powerwall+ Datasheet 2024 (energylibrary.tesla.com)
    UL 1741 SBManufacturer claim · equipment listingClaimedListed when checked

    Printed exactly as shown in the Compliance Information tables of Tesla's Powerwall+ datasheet: "PV Certifications UL 1699B, UL 1741, UL 3741, UL 1741 SA, UL 1741 SB, UL 1998 (US), IEEE 1547-2018, IEEE 1547.1". No certificate number, issuer or scope is printed beyond this row; no issuer directory was checked.

    Manufacturer document

    Official datasheet: Tesla Powerwall+ Datasheet 2024 (energylibrary.tesla.com)
    UL 1998 (US)Manufacturer claim · equipment listingClaimedListed when checked

    Printed exactly as shown in the Compliance Information tables of Tesla's Powerwall+ datasheet: "PV Certifications UL 1699B, UL 1741, UL 3741, UL 1741 SA, UL 1741 SB, UL 1998 (US), IEEE 1547-2018, IEEE 1547.1". No certificate number, issuer or scope is printed beyond this row; no issuer directory was checked.

    Manufacturer document

    Official datasheet: Tesla Powerwall+ Datasheet 2024 (energylibrary.tesla.com)
    IEEE 1547-2018Manufacturer claim · equipment listingClaimedListed when checked

    Printed exactly as shown in the Compliance Information tables of Tesla's Powerwall+ datasheet: "PV Certifications UL 1699B, UL 1741, UL 3741, UL 1741 SA, UL 1741 SB, UL 1998 (US), IEEE 1547-2018, IEEE 1547.1". No certificate number, issuer or scope is printed beyond this row; no issuer directory was checked.

    Manufacturer document

    Official datasheet: Tesla Powerwall+ Datasheet 2024 (energylibrary.tesla.com)
    IEEE 1547.1Manufacturer claim · equipment listingClaimedListed when checked

    Printed exactly as shown in the Compliance Information tables of Tesla's Powerwall+ datasheet: "PV Certifications UL 1699B, UL 1741, UL 3741, UL 1741 SA, UL 1741 SB, UL 1998 (US), IEEE 1547-2018, IEEE 1547.1". No certificate number, issuer or scope is printed beyond this row; no issuer directory was checked.

    Manufacturer document

    Official datasheet: Tesla Powerwall+ Datasheet 2024 (energylibrary.tesla.com)
    UL 1642Manufacturer claim · equipment listingClaimedListed when checked

    Printed exactly as shown in the Compliance Information tables of Tesla's Powerwall+ datasheet: "Battery Energy Storage System Certifications UL 1642, UL 1741, UL 1741 PCS, UL 1741 SA, UL 1741 SB, UL 1973, UL 9540, IEEE 1547-2018, IEEE 1547.1, UN 38.3". No certificate number, issuer or scope is printed beyond this row; no issuer directory was checked.

    Manufacturer document

    Official datasheet: Tesla Powerwall+ Datasheet 2024 (energylibrary.tesla.com)
    UL 1741 PCSManufacturer claim · equipment listingClaimedListed when checked

    Printed exactly as shown in the Compliance Information tables of Tesla's Powerwall+ datasheet: "Battery Energy Storage System Certifications UL 1642, UL 1741, UL 1741 PCS, UL 1741 SA, UL 1741 SB, UL 1973, UL 9540, IEEE 1547-2018, IEEE 1547.1, UN 38.3". No certificate number, issuer or scope is printed beyond this row; no issuer directory was checked.

    Manufacturer document

    Official datasheet: Tesla Powerwall+ Datasheet 2024 (energylibrary.tesla.com)
    UL 1973Manufacturer claim · equipment listingClaimedListed when checked

    Printed exactly as shown in the Compliance Information tables of Tesla's Powerwall+ datasheet: "Battery Energy Storage System Certifications UL 1642, UL 1741, UL 1741 PCS, UL 1741 SA, UL 1741 SB, UL 1973, UL 9540, IEEE 1547-2018, IEEE 1547.1, UN 38.3". No certificate number, issuer or scope is printed beyond this row; no issuer directory was checked.

    Manufacturer document

    Official datasheet: Tesla Powerwall+ Datasheet 2024 (energylibrary.tesla.com)
    UL 9540Manufacturer claim · equipment listingClaimedListed when checked

    Printed exactly as shown in the Compliance Information tables of Tesla's Powerwall+ datasheet: "Battery Energy Storage System Certifications UL 1642, UL 1741, UL 1741 PCS, UL 1741 SA, UL 1741 SB, UL 1973, UL 9540, IEEE 1547-2018, IEEE 1547.1, UN 38.3". No certificate number, issuer or scope is printed beyond this row; no issuer directory was checked.

    Manufacturer document

    Official datasheet: Tesla Powerwall+ Datasheet 2024 (energylibrary.tesla.com)
    UN 38.3Manufacturer claim · equipment listingClaimedListed when checked

    Printed exactly as shown in the Compliance Information tables of Tesla's Powerwall+ datasheet: "Battery Energy Storage System Certifications UL 1642, UL 1741, UL 1741 PCS, UL 1741 SA, UL 1741 SB, UL 1973, UL 9540, IEEE 1547-2018, IEEE 1547.1, UN 38.3". No certificate number, issuer or scope is printed beyond this row; no issuer directory was checked.

    Manufacturer document

    Official datasheet: Tesla Powerwall+ Datasheet 2024 (energylibrary.tesla.com)
    FCC Part 15 Class BManufacturer claim · unresolved document setClaimedListed when checked

    Printed exactly as shown in the Compliance Information tables of Tesla's Powerwall+ datasheet: "Emissions FCC Part 15 Class B". No certificate number, issuer or scope is printed beyond this row; no issuer directory was checked.

    Manufacturer document

    Official datasheet: Tesla Powerwall+ Datasheet 2024 (energylibrary.tesla.com)
    RoHS Directive 2011/65/EUManufacturer claim · unresolved document setClaimedListed when checked

    Printed exactly as shown in the Compliance Information tables of Tesla's Powerwall+ datasheet: "Environmental RoHS Directive 2011/65/EU". No certificate number, issuer or scope is printed beyond this row; no issuer directory was checked.

    Manufacturer document

    Official datasheet: Tesla Powerwall+ Datasheet 2024 (energylibrary.tesla.com)
    AC156Manufacturer claim · unresolved document setClaimedListed when checked

    Printed exactly as shown in the Compliance Information tables of Tesla's Powerwall+ datasheet: "Seismic AC156, IEEE 693-2005 (high)". No certificate number, issuer or scope is printed beyond this row; no issuer directory was checked.

    Manufacturer document

    Official datasheet: Tesla Powerwall+ Datasheet 2024 (energylibrary.tesla.com)
    IEEE 693-2005Manufacturer claim · unresolved document setClaimedListed when checked

    Printed exactly as shown in the Compliance Information tables of Tesla's Powerwall+ datasheet: "Seismic AC156, IEEE 693-2005 (high)". No certificate number, issuer or scope is printed beyond this row; no issuer directory was checked.

    Manufacturer document

    Official datasheet: Tesla Powerwall+ Datasheet 2024 (energylibrary.tesla.com)
    Source details
    Revision
    Not stated
    Revision date
    Not stated

    Archived copy captured on 2026-09-28.

    Location: Technical, Mechanical, Environmental and Compliance specification tables

    Retrieved Sep 27, 2026

    Tesla's 2024 Powerwall+ datasheet, captured September 28, 2026 from energylibrary.tesla.com, the same Tesla-operated document host already cited by the catalog for Powerwall 3. www.tesla.com is fully blocked (HTTP 403 on every URL tried), so no tesla.com page could be checked for an explicit inbound link to this document, and it was not sought through another tool or client. The document's own path (docs/Public/EnergyStorage/Powerwall/+/Datasheet/en-us/) matches the internal path pattern used for the Powerwall 2 and Powerwall 3 datasheets. It prints its own title as "Powerwall+ 2024" and "2024 Powerwall+ Datasheet" but no other revision code.

    Archived copies

    Archived copy of a document published by Tesla, Inc.. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].

    Archived backupRevision not recorded · 0.53 MB

    Archived copy, unaltered, kept as a record of what Tesla, Inc. published. Original address: https://energylibrary.tesla.com/docs/Public/EnergyStorage/Powerwall/+/Datasheet/en-us/Powerwall-+-Datasheet.pdf. Copyright and takedown

    Source first found
    This copy captured
    Archived
    File detailsOriginal source
    Embedded creation date
    Embedded modification date
    Pages
    6

    Embedded dates are file metadata, not independent proof of publication.

    SHA-256: 0faf53c23981793d7bbd30e61e3b4573bb5c6e79c8929c6654848ecc31e20ebf

    Open
  • Warranty

  • Tesla Powerwall Limited Warranty (USA), Rev. 2.6Official · Tesla, Inc. · Official warranty · May 6, 2026 · PDF
    Source details
    Revision
    2.6
    Revision date
    May 6, 2026

    Archived copy captured on 2026-09-28.

    Location: Page 1, Applies to table and Ten Year Limited Warranty section

    Retrieved Sep 27, 2026

    Tesla's US limited warranty document, revision 2.6, effective May 6, 2026, captured September 28, 2026 from energylibrary.tesla.com. It covers Powerwall 2, Powerwall+, Powerwall 3 and Powerwall 3 Expansion together and lists each covered product's printed part numbers in its own table. www.tesla.com is fully blocked, so no tesla.com page could be checked for a link to this document; the same document is already cited by the catalog's tesla-powerwall3-us record at this same URL.

    Archived copies

    Archived copy of a document published by Tesla, Inc.. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].

    Archived backupRevision not recorded · 0.21 MB

    Archived copy, unaltered, kept as a record of what Tesla, Inc. published. Original address: https://energylibrary.tesla.com/docs/Public/EnergyStorage/Powerwall/General/Warranty/en-us/Powerwall-Warranty-EN.pdf. Copyright and takedown

    Source first found
    This copy captured
    Archived
    File detailsOriginal source
    Embedded creation date
    None
    Embedded modification date
    None
    Pages
    7

    Embedded dates are file metadata, not independent proof of publication.

    SHA-256: 77fb03b38a9ae2de8613ebab5eea4e7fa072c478a45e5cf8f69ab6ab80ca17dd

    Open

Archive and older revisions

Archive and older revisions0

Earlier revisions, archived captures and copies published by someone other than the manufacturer. Every one stays reachable.

Archived documents

Tesla Powerwall+ Datasheet 2024 (energylibrary.tesla.com)

Archived copy of a document published by Tesla, Inc.. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].

Archived backupRevision not recorded · 0.53 MB

Archived copy, unaltered, kept as a record of what Tesla, Inc. published. Original address: https://energylibrary.tesla.com/docs/Public/EnergyStorage/Powerwall/+/Datasheet/en-us/Powerwall-+-Datasheet.pdf. Copyright and takedown

Source first found
This copy captured
Archived
File detailsOriginal source
Embedded creation date
Embedded modification date
Pages
6

Embedded dates are file metadata, not independent proof of publication.

SHA-256: 0faf53c23981793d7bbd30e61e3b4573bb5c6e79c8929c6654848ecc31e20ebf

Tesla Powerwall Limited Warranty (USA), Rev. 2.6

Archived copy of a document published by Tesla, Inc.. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].

Archived backupRevision not recorded · 0.21 MB

Archived copy, unaltered, kept as a record of what Tesla, Inc. published. Original address: https://energylibrary.tesla.com/docs/Public/EnergyStorage/Powerwall/General/Warranty/en-us/Powerwall-Warranty-EN.pdf. Copyright and takedown

Source first found
This copy captured
Archived
File detailsOriginal source
Embedded creation date
None
Embedded modification date
None
Pages
7

Embedded dates are file metadata, not independent proof of publication.

SHA-256: 77fb03b38a9ae2de8613ebab5eea4e7fa072c478a45e5cf8f69ab6ab80ca17dd

Submit a document

Parts and accessories

No sourced accessories or replacement parts listed yet.

Model history

Model identity

Model
Powerwall+

Manufacturer SKU 1850000-xx-y · US market

  1. Observed Oct 23, 2026

    UL 9540: claimed

    Product / system scope unresolved. Listed on the California Energy Commission Energy Storage System List (data unchanged since October 21, 2026; downloaded October 23, 2026) as Tesla Inc. "1850000-XX-Y": UL 9540, certifying entity TUV Rheinland of North America, certificate date 2023-04-06, Ed. 2 : 2020, CEC listing date 2021-05-03. A state equipment list entry, not the certification body's own record.

    [4]

  2. Observed Oct 11, 2026

    CEC: claimed

    Product / system scope unresolved. Model 1850000-xx-y listed on the California Energy Commission Energy Storage System List (data unchanged since October 1, 2026; downloaded October 11, 2026) under Tesla Inc. (brand Powerwall +), as "1850000-XX-Y", CEC listing date 2021-05-03. The list prints "1850000-XX-Y"; the record's manufacturer SKU "1850000-xx-y" differs only in letter case. This is an equipment listing, not UL certification or complete-system approval.

    [3]

Other recorded fields

FieldValueConditionsSource
Evidence breakdown
method version: 0.21-personal
documented pct: 65
basis: usable
missing:
Warranty energy disclosure evidence needed
Lifetime / capacity evidence needed
Cell model disclosure evidence needed
criteria:
key: certificateEvidence
label: Certificates
value: 100
unit: evidence points
shown: CEC · UL 1699B +15
shown detail: CEC listed
state: verified
points: 45
ceiling: 45
weight: 45
share: 100
covered: yes
missing: no
folded: no
reason: Unknown
reason text: Unknown
note: CEC listing: full credit for the certificate criterion. Exact model found in the dated CEC equipment list. This is not a safety certification or system approval. Applies: CEC; UL 9540; UL 1973.
display note: Unknown
Sources: [3] [4]
key: years
label: Warranty term
value: 10
unit: years
shown: 10 years
shown detail: Unknown
state: documented
points: 13.33
ceiling: 20
weight: 20
share: 66.7
covered: yes
missing: no
folded: no
reason: Unknown
reason text: Unknown
note:
display note: Unknown
Sources: [1] [2]
key: throughputEvidence
label: Warranty energy disclosure
value: 0
unit: evidence points
shown: 37.8 MWh · not confirmed
shown detail: Unknown
state: unconfirmed
points: 0
ceiling: 10
weight: 10
share: 0
covered: no
missing: yes
folded: no
reason: Unknown
reason text: Unknown
note: No qualifying quantified warranty energy recorded. This is an evidence gap, not a performance judgment.
display note: Unknown
Sources: [2]
key: lifetime
label: Lifetime / capacity
value: Unknown
unit: MWh/kWh
shown: 37.8 MWh · not confirmed
shown detail: Unknown
state: unconfirmed
points: 0
ceiling: 20
weight: 20
share: Unknown
covered: no
missing: yes
folded: no
reason: not-counted
reason text: A value is on file but is not counted: it carries a warning or is not confirmed.
note: Lifetime amount or capacity needs confirmation. No lifetime-production bonus.
display note: Unknown
Sources: [2]
key: cellDisclosure
label: Cell model disclosure
value: 0
unit: disclosure points
shown: Research pending
shown detail: Unknown
state: pending
points: 0
ceiling: 5
weight: 5
share: 0
covered: no
missing: yes
folded: yes
reason: Unknown
reason text: Unknown
note: A sourced cell manufacturer and model are needed. Grade A, chemistry and cell capacity alone do not identify a cell model.
display note: Unknown
Sources: No source on record

Community discussions

No discussions linked yet. Search DIY Solar Forum

Sources

  1. Tesla Powerwall+ Datasheet 2024 (energylibrary.tesla.com) (Tesla, Inc. · manufacturer · observed Sep 27, 2026)
  2. Tesla Powerwall Limited Warranty (USA), Rev. 2.6 (Tesla, Inc. · manufacturer · observed Sep 27, 2026)
  3. CEC Energy Storage System List, official spreadsheet (data unchanged since October 1, 2026; downloaded October 11, 2026) (California Energy Commission · government equipment registry · Data unchanged since October 1, 2026 · observed Oct 10, 2026 · effective Oct 1, 2026)
  4. CEC Energy Storage System List, official spreadsheet (data unchanged since October 21, 2026; downloaded October 23, 2026) (California Energy Commission · government equipment registry · Data unchanged since October 21, 2026 · observed Oct 23, 2026 · effective Oct 21, 2026)

Sign in to report an error on this page

Similar products

All with a price

* Missing details