Charged Reviews · Quick reference
SunGoldPower 48V 100Ah Rack
- Brand
- SunGoldPower
- Model
- SG48100P
- SKU / part number
- SG48100P[12]
- Category
- Batteries

Energy and chemistry
| Nominal voltage | 51.2 V[1, 4] |
|---|---|
| Rated capacity | 100 Ah[1, 4] |
| Nominal energy | 5.12 kWh[1]Calculated |
| Usable energy | ? |
| Chemistry | LFP[1, 4] |
| Cell format | ? |
Charge and discharge
| Continuous charge current | 100 A[1, 4] |
|---|---|
| Continuous discharge current | 100 A[1, 4] |
| Maximum charge current | ? |
| Maximum discharge current | ? |
| Peak charge current | ? |
| Peak discharge current | ? |
| Continuous output power | 5.12 kW[1]Calculated |
| Peak output | ? |
| Maximum charge voltage | 57.6 V[4] |
| Charge cutoff voltage | ? |
| Discharge cutoff voltage | 43.2 V[4] |
BMS and communication
| BMS continuous current | ? |
|---|---|
| Communication protocols | RS232 / RS485 / CAN[1, 4] |
| Wireless monitoring | ? |
| Inverter compatibility | ? |
Operating temperature
| Charging temperature | 0 to 45 °C[4] |
|---|---|
| Discharging temperature | -20 to 60 °C[4] |
| Storage temperature | -10 to 45 °C[4] |
| Self-heating | ? |
Mechanical and mounting
| Dimensions | 460 D × 442 W × 133 H mm[1, 4] |
|---|---|
| Weight | 43 kg / 94.8 lb[1, 4] |
| Terminals | ? |
| Mounting / format | Server Rack[11] |
| Enclosure rating (IP) | IP31[1] |
Installation (from the manual)
Communication
| Communication ports | RS232--Using 6P6C vertical RJ11 socket; RS485 and CAN interface: RS485--Using 8P8C vertical RJ45 socket; CAN--Using 8P8C vertical RJ45 socket; Parallel communication port: RS485--Using 8P8C vertical RJ45 socket[1] |
|---|---|
| Address / DIP setting | When the battery packs are used in parallel, different PACK can be distinguished by their hardware addresses, and the hardware address of each PACK in the entire battery stack is unique. The hardware addresses can be set in sequence through the DIP switches on the board[1] |
Not in the manual: Torque, Conductors, Protection, Clearances and orientation, Grounding
System limits
| Maximum parallel units | 63[1, 4] |
|---|---|
| Series connection | ? |
| Maximum system energy | ? |
Page 1 of 2 · Installation values · ? means nothing is recordedAggregated, often community-reported information, not official documentation. Do not rely on it for installation, purchase or compliance decisions; always confirm values with the manufacturer’s official documentation. Charged Reviews accepts no responsibility for errors.