Printed as "7.4 Bluetooth Function 7.4.1 Download App" in the SRNE SR-Ket-C Series Energy Storage System User Manual (V1.0) (page 39, 7.4 Bluetooth Function). Section 7.4.2: connecting the device requires turning on Bluetooth and location permissions.
The Ket-C page and datasheet state "Cathode material is made from LiFePO4"; the manual prints "Cell chemistry LiFePO4" for the SR-HOF16B pack that makes up the system.
Install the protective grounding wire first and keep the device permanently connected to it
Printed as "the protective grounding wire must be installed first"; "The device shall be permanently connected to the protective grounding wire." in the SRNE SR-Ket-C Series Energy Storage System User Manual (V1.0) (page 8, 2.4.2 Grounding Requirements).
Printed as "6000 Cycles" in the Life cycle row, whose label gives the test conditions as 25℃, 0.5C charge and 0.5C discharge, to 70% end of life (EOL70%).
840 × 1,190 × 2,095 mm / 33.1 × 46.85 × 82.48 in converted
Printed as "840*1190mm" under "Dimensions(L*W)" and 2095mm under "Dimensions(H)" in the manual; the datasheet prints "840*1190*2095" under its Dimensions row (W x D x H, mm). Kept in printed order because the two documents name the first two axes differently.
Where: Manual V1.0 section 3.1 Battery System Specifications, SR-Ket209C (fourth) column, Dimensions (L*W) and (H)
Printed as "Installation Location Rack Mounting Recommend Depth of Discharge ≤95%" in the SRNE SR-Ket-C Series Energy Storage System User Manual (V1.0) (page 10, 3.1 Battery System Specifications, Installation Location row).
Where: PDF page 10, 3.1 Battery System Specifications, Installation Location row
Printed as "Peak Discharge (3S,25℃) 220/220A" in the SRNE SR-Ket-C Series Energy Storage System User Manual (V1.0) (page 10, 3.1 Battery System Specifications, Peak Discharge row). One value printed for every model of the table, for 3 seconds at 25 °C.
Where: PDF page 10, 3.1 Battery System Specifications, Peak Discharge row
Printed as "System Energy 209kWh" in the SR-Ket-C manual (V1.0); the Ket C datasheet (V1.0) and the Ket-C product page print "System Energy (kWh)" 209. The system is printed as 13 SR-HOF16B battery packs in series.
Where: Manual V1.0 section 3.1 Battery System Specifications, SR-Ket209C (fourth) column, System Energy
PCS: battery communication terminal to the PCS (RJ45, CAN); LCD: external LCD terminal; P-IN: connection with previous PDU communication; P-OUT: connection with next PDU communication; COM: BMS upgrade and PC connection; BAT OUT: fan power and daisy chain
Printed as "P-IN Connection position with previous PDU communication."; "P-OUT Connection position with next PDU communication."; "COM BMS upgrade interface and connection PC interface."; "LCD External LCD terminal." in the SRNE SR-Ket-C Series Energy Storage System User Manual (V1.0) (page 16, 3.5.3 PDU Module introduction (SR-PDU200C)).
Where: PDF page 16, 3.5.3 PDU Module introduction (SR-PDU200C)
The energy storage cannot be installed forwardly, horizontally, inversely, backwardly or sideways.
Printed as "The energy storage cannot be installed forwardly, horizontally, inversely, backwardly or sideways." in the SRNE SR-Ket-C Series Energy Storage System User Manual (V1.0) (page 19, 5.3.1 Basic Requirements).
Printed as "PCS COM battery communication terminal: (RJ45 port) follow the CAN protocol" in the SRNE SR-Ket-C Series Energy Storage System User Manual (V1.0) (page 16, 3.5.3 PDU Module introduction, PCS port).
Where: PDF page 16, 3.5.3 PDU Module introduction, PCS port
Printed as "Communication interfaces CAN/RS485//WIFI"; "7.4 Bluetooth Function 7.4.1 Download App" in the SRNE SR-Ket-C Series Energy Storage System User Manual (V1.0) (pages 10, 39, 3.1 Communication interfaces row; 7.3 WIFI Function; 7.4 Bluetooth Function). Section 7.5 says only the 2.4G WiFi band is supported.
Where: PDF pages 10, 39, 3.1 Communication interfaces row; 7.3 WIFI Function; 7.4 Bluetooth Function
2,094.16 L* (Calculated enclosure volume: W × H × D in mm ÷ 1,000,000)840 × 1,190 × 2,095 mm / 33.1 × 46.85 × 82.48 in1,721.5 kg / 3,795 lb0.1 kWh/L* (Rated or usable capacity shown on this card ÷ enclosure volume)
Evidence score
4/100Missing details20% documented
The Evidence score uses the priorities you choose. It counts published documents, such as certificates and warranty terms, and it compares a documented figure with the best documented figure of the same kind. It does not count owner reviews, and it is not a verdict on product quality or on how many people have reviewed it. A low score can mean little is documented, or that a documented figure is below the best of its kind. Undisclosed data scores 0.
Missing details. This number counts only the evidence recorded so far. The source review for this product is not finished, or the maker has not disclosed enough, so the number can only go up.
Missing for this product: Certificates evidence needed; Warranty term needed; Warranty energy disclosure evidence needed; Cell model disclosure evidence needed.
Industrial/Commercial ESS · High voltage · Over 100 kWh · Rated capacity
The warranty term and the lifetime energy are each scored against the best documented value for a home storage battery: a value earns its share of that best, times the weight. A documented value always earns points; an undisclosed one earns 0.
Lifetime / capacity6,000 cycles4 / 20
Cycle rating disclosed · 20% weight
Documented cycle rating earns 20% of this criterion. More evidence is needed to compare lifetime MWh per kWh.
Research pending, 0 points: Certificates, Warranty term, Warranty energy disclosure, Cell model disclosure.
Computed from public specifications and evidence records. Warranty duration is not service quality; certificate evidence points are not a safety rating. Compatibility and installation limits still apply.
Captured by scripts/prepare-brand-sweep-sep21.mjs on 2026-09-29.
Location: Section 1.1 (page 2); section 3.1 Battery System Specifications (pages 10 and 11)
Retrieved Sep 29, 2026
SRNE's installation and user manual for SR-Ket96C to SR-Ket209C, file version V1.0, linked from the Ket-C page (listed as updated November 27, 2025), captured September 29, 2026. Its section 1 names the series "SR-Ket-B series" while listing the Ket C models; section 3.1 prints one column per model. Manufacturer claims, not independent tests.
Archived copies
Archived copy of a document published by SRNE Solar Co., Ltd.. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Captured by scripts/prepare-brand-sweep-sep21.mjs on 2026-09-29.
Location: Pages 2 and 3 (Battery System Module tables)
Retrieved Sep 29, 2026
SRNE's Ket C datasheet, version V1.0, file SR-Ket210C_V1.0-2025826.pdf, linked from the Ket-C page, captured September 29, 2026. Page 2 prints SR-Ket96C to 144C and page 3 SR-Ket160C to 209C. The PDF text layer also carries an unseen leftover Ket A table; values here were read from the rendered pages and each quoted string was checked against the text layer. Manufacturer claims, not independent tests.
Archived copies
Archived copy of a document published by SRNE Solar Co., Ltd.. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Captured by scripts/prepare-brand-sweep-sep21.mjs on 2026-09-29.
Location: Page text
Retrieved Sep 29, 2026
SRNE's own product page for the Ket C high-voltage rack battery systems, captured September 29, 2026. It prints an overview for SR-Ket96C to SR-Ket209C and links a datasheet whose file is named SR-Ket210C_V1.0 (it prints SR-Ket96C to SR-Ket209C) and the SR-Ket-210C user manual (V1.0). Manufacturer claims, not independent tests.
Captured by scripts/prepare-brand-sweep-sep21.mjs on 2026-09-29.
Location: Page text
Retrieved Sep 29, 2026
SRNE's own Commercial & Industrial Energy Storage Solutions page, captured September 29, 2026. Cited only for the products it lists under that heading: Ket-C, Ket-B, Ket-A, SR-Box225C-60K, SR-Box112C-55K and SR-Box112C-55K-Mini. Manufacturer claims, not independent tests.
SRNE SR-Ket-C Series Energy Storage System User Manual (V1.0)
Archived copy of a document published by SRNE Solar Co., Ltd.. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
SRNE SR-Ket96C/112C/128C/144C and SR-Ket160C/176C/192C/209C Lithium Battery Energy Storage datasheet (V1.0)
Archived copy of a document published by SRNE Solar Co., Ltd.. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
No sourced accessories or replacement parts listed yet.
Model history
Model identity
Model
SR-Ket209C
Manufacturer SKU unknown
No historical observations recorded yet.
Other recorded fields
Field
Value
Conditions
Source
Evidence breakdown
method version: 0.21-personal
documented pct: 20
basis: nominal
missing:
Certificates evidence needed
Warranty term needed
Warranty energy disclosure evidence needed
Cell model disclosure evidence needed
criteria:
key: certificateEvidence
label: Certificates
value: 0
unit: evidence points
shown: Research pending
shown detail: Unknown
state: pending
points: 0
ceiling: 45
weight: 45
share: 0
covered: no
missing: yes
folded: yes
reason: Unknown
reason text: Unknown
note: No qualifying applicable evidence recorded. This is not proof that certification is absent. Applies: UL 9540; UL 1973; CEC not assessed for commercial and industrial equipment in this catalog. UL 9540A is recorded but not scored: a thermal-runaway test method, recorded as a documented report and never scored as a listing.
display note: Unknown
Sources: No source on record
key: years
label: Warranty term
value: Unknown
unit: years
shown: Research pending
shown detail: Unknown
state: pending
points: 0
ceiling: 20
weight: 20
share: Unknown
covered: no
missing: yes
folded: yes
reason: undocumented
reason text: Not documented. Undisclosed data scores 0.
note: Not documented.
display note: Unknown
Sources: No source on record
key: throughputEvidence
label: Warranty energy disclosure
value: 0
unit: evidence points
shown: Research pending
shown detail: Unknown
state: pending
points: 0
ceiling: 10
weight: 10
share: 0
covered: no
missing: yes
folded: yes
reason: Unknown
reason text: Unknown
note: No qualifying quantified warranty energy recorded. This is an evidence gap, not a performance judgment.
display note: Unknown
Sources: No source on record
key: lifetime
label: Lifetime / capacity
value: Unknown
unit: MWh/kWh
shown: 6,000 cycles
shown detail: Unknown
state: documented
points: 4
ceiling: 20
weight: 20
share: Unknown
covered: yes
missing: no
folded: no
reason: Unknown
reason text: Unknown
note: Documented cycle rating earns 20% of this criterion. More evidence is needed to compare lifetime MWh per kWh.