Charged Reviews · Quick reference
SOK SK24V150PH
- Brand
- SOK
- Model
- SK24V150PH
- SKU / part number
- SK24V150PH[3]
- Category
- Batteries

Energy and chemistry
| Nominal voltage | 25.6 V[3] |
|---|---|
| Rated capacity | 150 Ah[1] |
| Nominal energy | 3.84 kWh[3] |
| Usable energy | ? |
| Chemistry | LiFePO4 (page title and description call it a LiFePO4 / lithium iron phosphate battery)[1] |
| Cell format | prismatic[4] |
Charge and discharge
| Continuous charge current | 150 A[4] |
|---|---|
| Continuous discharge current | 200 A[1] |
| Maximum charge current | 200 A[1] |
| Maximum discharge current | 200 A[2] |
| Peak charge current | 170 A[4] |
| Peak discharge current | 800 A[4]Needs confirmation |
| Continuous output power | ? |
| Peak output | 170 A for 1 min; 800 A for 10 s[4] |
| Maximum charge voltage | 27.6 V[1] |
| Charge cutoff voltage | ? |
| Discharge cutoff voltage | 20 V[3] |
BMS and communication
| BMS continuous current | ? |
|---|---|
| Communication protocols | CAN Communication with Victron Inverter : Supports CAN protocol, ensuring seamless communication and integration with Victron Cerbo GX; Bluetooth 5.1[1] |
| Wireless monitoring | Bluetooth[4] |
| Inverter compatibility | ? |
Operating temperature
| Charging temperature | -20 to 50 °C[3] |
|---|---|
| Discharging temperature | -20 to 60 °C[3] |
| Storage temperature | -5 to 35 °C[3] |
| Self-heating | Yes[3, 7] |
Mechanical and mounting
| Dimensions | 434.34 D × 238.76 D × 276.86 D mm[1]Calculated |
|---|---|
| Weight | 31.75 kg / 70 lb[1]Calculated |
| Terminals | M8, 5/16 lugs[2] |
| Mounting / format | ? |
| Enclosure rating (IP) | IP67[3] |
Installation (from the manual)
Torque
| Main terminal torque | 9 to 11 N·m(79.66 to 97.36 in-lb*)[4] |
|---|---|
| Communication terminal torque | ? |
| Ground terminal torque | ? |
Protection
| Fuse or breaker | A fuse with an Ampere Interrupting Capacity of 2000 Amps or higher is recommended within 18 inches of the positive battery terminal[4] |
|---|
Communication
| Communication ports | Link OUT: For internal and external communication; Link IN: For internal and external communication[4] |
|---|---|
| Address / DIP setting | ? |
Not in the manual: Conductors, Clearances and orientation, Grounding
System limits
| Maximum parallel units | 15[4]Needs confirmation |
|---|---|
| Series connection | 2[3] |
| Maximum system energy | ? |
Page 1 of 2 · Installation values · ? means nothing is recordedAggregated, often community-reported information, not official documentation. Do not rely on it for installation, purchase or compliance decisions; always confirm values with the manufacturer’s official documentation. Charged Reviews accepts no responsibility for errors.