Charged Reviews · Quick reference
RICH SOLAR ALPHA 5 PRO
- Brand
- RICH SOLAR
- Model
- RS-B5121P
- SKU / part number
- RS-B5121P[9]
- Category
- Batteries

Energy and chemistry
| Nominal voltage | 51.2 V[1] |
|---|---|
| Rated capacity | 100 Ah[1] |
| Nominal energy | 5.12 kWh[3]Calculated |
| Usable energy | ? |
| Chemistry | LiFePO₄[7] |
| Cell format | 16S1P[3] |
Charge and discharge
| Continuous charge current | 20 A[7] |
|---|---|
| Continuous discharge current | 50 A[3] |
| Maximum charge current | 100 A[5] |
| Maximum discharge current | 100 A[3] |
| Peak charge current | ? |
| Peak discharge current | ? |
| Continuous output power | ? |
| Peak output | ? |
| Maximum charge voltage | 57.6 V[3, 7] |
| Charge cutoff voltage | ? |
| Discharge cutoff voltage | 44.8 V[3]Needs confirmation |
BMS and communication
| BMS continuous current | ? |
|---|---|
| Communication protocols | RS485/RS232/CAN[11] |
| Wireless monitoring | ? |
| Inverter compatibility | RS485 and CAN: RICH SOLAR, PYLON, Growatt, Victron Energy, EG4 (Luxpower; RS485 as Luxpower V03), Schneider. RS485 only: PACE MODBUS. CAN only: SMA, GoodWe, SOLIS, MEGAREVO.[3] |
Operating temperature
| Charging temperature | 0 to 60 °C[7]Calculated |
|---|---|
| Discharging temperature | -20 to 65 °C[7]Calculated |
| Storage temperature | ? |
| Self-heating | ? |
Mechanical and mounting
| Dimensions | 452.1 W × 132.1 H × 449.6 L mm[5]Calculated |
|---|---|
| Weight | 45.77 kg / 100.91 lb[1]Calculated |
| Terminals | ? |
| Mounting / format | Server rackSite classificationBased on[12] |
| Enclosure rating (IP) | IP21[5] |
Installation (from the manual)
Conductors
| Cable size | 4 AWG (25 mm²)[3] |
|---|
Protection
| Fuse or breaker | ADC isolator is recommended to be add on the power circuit between inverter and battery, recommended rating at 120Amps per set of external power cable[3] |
|---|
Grounding
| Grounding | Battery system must be well grounded and the resistance must be less than 4Ω[3] |
|---|
Communication
| Communication ports | RS232 communication port: (RJ11 port) comply with RS232 protocol (baud rate: 9600), for manufacturers or professional engineers debugging or service; CAN/RS485 communication port: (RJ45 port) follow CAN protocol and RS485 protocol, for output batteries information, the battery uses this interface to communicate with external inverters, PCS and other devices; Multi-device parallel connection: The two RJ45 ports are the same. Comply with RS485 protocol (baud rate: 9600), used for parallel communication between batteries[3] |
|---|---|
| Address / DIP setting | When the battery communicates with the inverter, the address of the battery pack must be set to 1, and the address of the parallel slave should be greater than 1[3] |
Not in the manual: Torque, Clearances and orientation
System limits
| Maximum parallel units | 30[7]Needs confirmation |
|---|---|
| Series connection | No[3] |
| Maximum system energy | ? |
Page 1 of 2 · Installation values · ? means nothing is recordedAggregated, often community-reported information, not official documentation. Do not rely on it for installation, purchase or compliance decisions; always confirm values with the manufacturer’s official documentation. Charged Reviews accepts no responsibility for errors.