Charged ReviewsSaved 0Compare 0Login
Renon Power
Integrated AC storage

Renon ECube 60AP 61.44 kWh battery cabinet, 480V application (R-EC060060A1-US)

Key specs

Weight1,069.57 kg / 2,358 lb converted
Nominal energy61.44 kWh
Continuous output60 kW
Nominal voltage614.4 V
Max PV voltage1,000 V
Cycle life8,000 cycles

1 spec not documented yet: usable energyHelp fill in ›

All specifications

Identity

BrandRenon Power · Website
ModelR-EC060060A1-US
MarketUS
Manufacturer SKUR-EC060060A1-US
About brandRenon Power makes battery energy storage systems: residential batteries such as the Xtreme LV, Xcellent Plus and EBrick, and commercial and industrial systems such as the ECube 60AP.
SKU detail
locator: Page 5, General Parameters, Product Model
conditions: Printed as the Product Model in the parameter table for the 480V application.
Sources: [1]
FieldValueConditionsSource
ChemistryLiFePO4Printed as LiFePO4 in the battery value run.
Where: Page 5, Cell Chemistry
[1]
Weight1,069.57 kg / 2,358 lb converted
Printed as "~2358" lb (approximate) for the battery cabinet.
Where: Page 5, Battery Cabinet Weight Approximate (lb)
Sources
Converted: 2358 lb x 0.45359237 kg/lb, rounded to 0.01 kg
[1]
Cycle life8,000 cycles
Printed as ">8000 cycles" with a recommended depth of discharge of 90%.
Where: Page 5, Cycle Life
[1]
MPPT count4
The PV value run reads "78 150~850 180 1000 36 55 4 2 60" against Max. Allowed PV Power (STC)(kW), MPPT Voltage Range (V), Start up Voltage (V), Max. Input Voltage (V), Max. Operating Input Current per MPPT (A), Max. Short Circuit Current per MPPT (A), No. of MPP Trackers, No. of PV Strings per MPPT and Max. AC Coupled Input (kW).
Where: Page 5, PV Input, No. of MPP Trackers
[1]
AC voltage277/480 V
Printed as 277/480 V (three phase) at the start of the AC value run.
Where: Page 5, Nominal AC Voltage (3)(V)
[1]
DimensionsW 749.3 × H 2,319 × D 950 mm / W 29.5 × H 91.3 × D 37.4 in
Printed in inches as "~29.5*37.4*91.3" (approximate) for the battery cabinet, W*D*H.
Where: Page 5, Battery Cabinet Dimension - W*D*H (in)
Sources
Converted: 29.5 x 37.4 x 91.3 in x 25.4 mm/in, rounded to 0.1 mm
[1]
Battery format
Industrial cabinet
Site classificationBased onOfficial datasheet
Details

Charged Reviews classified this product from the documents it is based on. It is our own grouping, not a manufacturer claim.

Printed as "The ultimate commercial and industrial energy storage solution" and "Battery Cabinet Dimension - W*D*H (in)". Classified as Industrial cabinet from the maker's own words for this model (PM decision, October 13, 2026: a commercial or industrial battery cabinet is Industrial cabinet).

Official datasheet: Renon ECube 60AP US datasheet

Location: Renon ECube 60AP US datasheet, introduction, page 1 and general parameters, page 5

CommunicationsCAN; RS485; WiFi; LTEPrinted as "CAN, RS485, WiFi, LTE".
Where: Page 5, Communication Interface
[1]
Efficiency96.5 %
Printed as 96.5% for CEC Efficiency, after "5ms (adjustable)" for the backup transfer time.
Where: Page 5, CEC Efficiency
[1]
MPPT voltage150 to 850 V
Printed in the PV value run "78 150~850 180 1000 36 55 4 2 60".
Where: Page 5, MPPT Voltage Range (V)
[1]
Solar array78 kW
Printed in the PV value run "78 150~850 180 1000 36 55 4 2 60".
Where: Page 5, Max. Allowed PV Power (STC)(kW)
[1]
Enclosure ratingIP55Printed as IP55.
Where: Page 5, IP Rating
[1]
Max PV voltage1,000 V
Printed in the PV value run "78 150~850 180 1000 36 55 4 2 60".
Where: Page 5, Max. Input Voltage (V)
[1]
Transfer time5 msPrinted as "5ms (adjustable)".
Where: Page 5, Backup Transfer Time
[1]
Nominal voltage614.4 V
Printed as 614.4 in the battery value run "LiFePO4 5.12 51.2 100 12S1P 614.4 562.5~681.6 61.44 95"; system operating voltage 562.5~681.6 V.
Where: Page 5, System Nominal Voltage (V)
[1]
Max parallel units6
Printed as "Max. 6 System in Parallel".
Where: Page 5, General Parameters, System Scalability
[1]
Nominal energy61.44 kWh
The battery value run reads "LiFePO4 5.12 51.2 100 12S1P 614.4 562.5~681.6 61.44 95" against Cell Chemistry, Module Energy (kWh), Module Nominal Voltage (V), Module Capacity (Ah), Battery Module Combination, System Nominal Voltage (V), System Operating Voltage (V), System Energy (kWh) and Charge/Discharge Current (A).
Where: Page 5, Battery Energy Storage, System Energy (kWh)
[1]
Continuous output60 kW
The AC value run reads "277/480 50/60 60 72.3 90 200 180" against Nominal AC Voltage, Grid Frequency, Real Power Max Continuous, Max. Output Current (72.3 A), Peak Apparent Power (10s, off-grid; 90 kVA), Max. Grid Passthrough Current (10min) and Continuous Grid Passthrough Current.
Where: Page 5, AC Output (EPS), Real Power, Max Continuous (3)(kW)
[1]
Operating temperature-30 to 55 °C / -22 to 131 °F convertedPrinted as "-30~55/-22~131" (°C/°F).
Where: Page 5, Operation Temperature (°C/°F)
[1]

Owner reviews

No owner reviews yet
Write a review

Sellers

No listed sellers in this data.

Price history

No seller price history.

Quick reference sheet

Basic specs
61.44 kWhDischarge 60 kWCharge Unknown
$ / rated kWh
Unavailable
Warranty
10 yearsSee terms
Lifetime production
Not published
Size
1,650.75 L* (Calculated enclosure volume: W × H × D in mm ÷ 1,000,000)W: 749.3 × H: 2,319 × D: 950 mm / W: 29.5 × H: 91.3 × D: 37.4 in1,069.57 kg / 2,358 lb0.04 kWh/L* (Rated or usable capacity shown on this card ÷ enclosure volume)

Evidence score

62/100Missing details85% documented

The Evidence score uses the priorities you choose. It counts published documents, such as certificates and warranty terms, and it compares a documented figure with the best documented figure of the same kind. It does not count owner reviews, and it is not a verdict on product quality or on how many people have reviewed it. A low score can mean little is documented, or that a documented figure is below the best of its kind. Undisclosed data scores 0.

Missing details. This number counts only the evidence recorded so far. The source review for this product is not finished, or the maker has not disclosed enough, so the number can only go up.

Missing for this product: Warranty energy disclosure evidence needed; Cell model disclosure evidence needed.

AC-coupled · Industrial cabinet · Usable capacity

The warranty term and the lifetime energy are each scored against the best documented value for a home storage battery: a value earns its share of that best, times the weight. A documented value always earns points; an undisclosed one earns 0.

CertificatesCEC · UL 9540 +2CEC listed45 / 45

100 evidence points · 45% weight

CEC listing: full credit for the certificate criterion. Exact model found in the dated CEC equipment list. This is not a safety certification or system approval. Applies: CEC; UL 9540; UL 1973.

100 / 100 × 45 = 45 points.

[2] [3]

Warranty term10 years13.33 / 20

10 years · 20% weight

10 of 15 years, the best documented for a home storage battery (printed by the maker): Blue Ion LX battery energy storage system (125 kW / 128 kWh)

Printed as "10 years" after the cycle life.

66.7 / 100 × 20 = 13.33 points.

[1]

Lifetime / capacity8,000 cycles4 / 20

Cycle rating disclosed · 20% weight

Documented cycle rating earns 20% of this criterion. More evidence is needed to compare lifetime MWh per kWh.

20 × 0.2 = 4 points.

[1]

Research pending, 0 points: Warranty energy disclosure, Cell model disclosure.

Computed from public specifications and evidence records. Warranty duration is not service quality; certificate evidence points are not a safety rating. Compatibility and installation limits still apply.

Certificates

What this shows: what each record says and how far it reaches. It does not mean the product is approved.
UL 1973manufacturer claimpresent at observation[1]
Scope
battery pack scope unverified
Covered models
R-EC060060A1-US
Limitations
A manufacturer claim, not a listing or certificate. Printed as "ANSI/CAN/UL 1973:2022" in the "Certification (Battery)" row ("ANSI/CAN/UL 1973:2022 ANSI/CAN/UL 9540:2020 UL 9540A, FCC Part 15 Subpart B:2023", read from the printed layout; the inverter row follows separately) of the General Parameters table for Product Model R-EC060060A1-US ("Product Parameter (For 480V Application)", page 5) in Renon's ECube 60AP US datasheet, captured October 1, 2026. The datasheet does not say which module or cabinet assembly was certified. No issuer, certificate or report number is printed; the issuer's record was not checked.
Record detail
Issued: Not stated
Valid from: Not stated
Expiry: Not stated
Issuer checked: Oct 1, 2026
Source
[1]
UL 9540Amanufacturer claimpresent at observation[1]
Scope
battery pack scope unverified
Covered models
R-EC060060A1-US
Limitations
A manufacturer claim, not a test report. Printed as "UL 9540A" in the "Certification (Battery)" row ("ANSI/CAN/UL 1973:2022 ANSI/CAN/UL 9540:2020 UL 9540A, FCC Part 15 Subpart B:2023", read from the printed layout; the inverter row follows separately) of the General Parameters table for Product Model R-EC060060A1-US ("Product Parameter (For 480V Application)", page 5) in Renon's ECube 60AP US datasheet, captured October 1, 2026. UL 9540A is a fire test method, not a certification; no test level, laboratory or report number is printed and no report was checked.
Record detail
Issued: Not stated
Valid from: Not stated
Expiry: Not stated
Issuer checked: Oct 1, 2026
Edition as printed: Not printed
Source
[1]
CECauthority listing reportedlisted as of snapshot[2]
Scope
equipment listing
Covered models
R-EC060060A1-US
Limitations
Model R-EC060060A1-US listed on the California Energy Commission Energy Storage System List (data unchanged since October 1, 2026; downloaded October 11, 2026) under Renon Power Technology Inc, as "R-EC060060A1-US", CEC listing date 2026-02-11. This is an equipment listing, not UL certification or complete-system approval.
Record detail
Issued: Not stated
Valid from: Feb 11, 2026
Expiry: Not stated
Issuer checked: Oct 11, 2026
Source
[2]
UL 9540authority listing reportedlisted as of snapshot[3]
Scope
equipment listing
Covered models
R-EC060060A1-US
Limitations
Listed on the California Energy Commission Energy Storage System List (data unchanged since October 21, 2026; downloaded October 23, 2026) as Renon Power Technology Inc "R-EC060060A1-US": UL 9540, certifying entity TUV Rheinland of North America, certificate date 2025-08-14, Ed. 3 : 2023, CEC listing date 2026-02-11. A state equipment list entry, not the certification body's own record.
Record detail
Issued: Not stated
Valid from: Aug 14, 2025
Expiry: Not stated
Issuer checked: Oct 23, 2026
Edition as printed: Ed. 3 : 2023
Source
[3]

Warranty

FieldValueConditionsSource
Warranty term10 yearsPrinted as "10 years" after the cycle life.
Where: Page 5, General Parameters, Warranty
[1]

Recalls / legal notices

No recalls on file. All notices · Report a notice

This register is incomplete. A missing notice does not establish that a product has no recalls.

Documents

  • Manuals

  • Renon ECube 60AP-US installation manual (2025, 6th edition)Official · Renon Power · Official user manual · PDF
    Source details
    Revision
    2025 6th edition
    Revision date
    Not stated

    Archived copy captured on 2026-10-28.

    Location: Model list

    Retrieved Oct 28, 2026

    Renon Power's own installation manual for the ECube 60AP-US, 2025 6th edition, printing the models R-EC060030A1-US and R-EC060060A1-US. Served from Renon's own site. Manufacturer claims, not independent tests.

    Archived copies

    Archived copy of a document published by Renon Power. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].

    Archived backup2025 6th edition · 5.66 MB

    Archived copy, unaltered, kept as a record of what Renon Power published. Original address: https://www.renonpower.com/uploadfile/2025/1231/Installation-Manual-ECube-60AP-US.pdf. Copyright and takedown

    Source first found
    This copy captured
    Archived
    File detailsOriginal source
    Embedded creation date
    Embedded modification date
    Pages
    25

    Embedded dates are file metadata, not independent proof of publication.

    SHA-256: aca4e5333b611f219cc7a107e52c234a83becdcdd8d2471cea6261ae93891aec

    Open
  • Datasheets

  • Renon ECube 60AP-US technical agreement (A04, 2025 4th edition)Official · Renon Power · Official datasheet · PDF
    Source details
    Revision
    A04 (2025 4th edition)
    Revision date
    Not stated

    Archived copy captured on 2026-10-28.

    Location: Model and specification tables

    Retrieved Oct 28, 2026

    Renon Power's own technical agreement (specification document) for the ECube 60AP-US, version A04, 2025 4th edition, printing the models R-EC060030A1-US and R-EC060060A1-US. Served from Renon's own site. Manufacturer claims, not independent tests.

    Archived copies

    Archived copy of a document published by Renon Power. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].

    Archived backupA04 (2025 4th edition) · 2.32 MB

    Archived copy, unaltered, kept as a record of what Renon Power published. Original address: https://www.renonpower.com/uploadfile/2025/1106/Technical-Agreement-ECube-60AP-US-A04.pdf. Copyright and takedown

    Source first found
    This copy captured
    Archived
    File detailsOriginal source
    Embedded creation date
    Embedded modification date
    Pages
    24

    Embedded dates are file metadata, not independent proof of publication.

    SHA-256: 0f257298bf13629d32bc194b3bbc2d90f1e10042c5a9b6338e8ee974c99928fd

    Open

Archive and older revisions

Archive and older revisions2

Earlier revisions, archived captures and copies published by someone other than the manufacturer. Every one stays reachable.

  • Renon ECube 60AP US datasheetOfficial · Renon Power · Official datasheet · PDF
    Certificate & compliance claims (2)
    UL 1973Manufacturer claim · battery pack scope unverifiedClaimedListed when checked

    A manufacturer claim, not a listing or certificate. Printed as "ANSI/CAN/UL 1973:2022" in the "Certification (Battery)" row ("ANSI/CAN/UL 1973:2022 ANSI/CAN/UL 9540:2020 UL 9540A, FCC Part 15 Subpart B:2023", read from the printed layout; the inverter row follows separately) of the General Parameters table for Product Model R-EC060060A1-US ("Product Parameter (For 480V Application)", page 5) in Renon's ECube 60AP US datasheet, captured October 1, 2026. The datasheet does not say which module or cabinet assembly was certified. No issuer, certificate or report number is printed; the issuer's record was not checked.

    Manufacturer document

    Official datasheet: Renon ECube 60AP US datasheet
    UL 9540AManufacturer claim · battery pack scope unverifiedClaimedListed when checked

    A manufacturer claim, not a test report. Printed as "UL 9540A" in the "Certification (Battery)" row ("ANSI/CAN/UL 1973:2022 ANSI/CAN/UL 9540:2020 UL 9540A, FCC Part 15 Subpart B:2023", read from the printed layout; the inverter row follows separately) of the General Parameters table for Product Model R-EC060060A1-US ("Product Parameter (For 480V Application)", page 5) in Renon's ECube 60AP US datasheet, captured October 1, 2026. UL 9540A is a fire test method, not a certification; no test level, laboratory or report number is printed and no report was checked.

    Manufacturer document

    Official datasheet: Renon ECube 60AP US datasheet
    Source details
    Revision
    Not stated
    Revision date
    Not stated

    Archived copy captured on 2026-10-01.

    Location: Pages 5 and 6, Product Parameter

    Retrieved Oct 1, 2026

    Renon Power's own six-page US datasheet for the ECube 60AP 60 kWh air-cooled battery cabinet, linked from Renon's ECube 60AP page, captured October 1, 2026. It prints one parameter table for the 480 V application (R-EC060060A1-US) and one for the 208 V application (R-EC060030A1-US). Labels and values print in separate runs; values are matched to labels by order. Manufacturer claims, not independently verified.

    Archived copies

    Archived copy of a document published by Renon Power. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].

    Archived backupRevision not recorded · 3.55 MB

    Archived copy, unaltered, kept as a record of what Renon Power published. Original address: https://www.renonpower.com/uploadfile/2025/1114/RN-ECube-60AP-US.pdf. Copyright and takedown

    Source first found
    This copy captured
    Archived
    File detailsOriginal source
    Embedded creation date
    Embedded modification date
    Pages
    6

    Embedded dates are file metadata, not independent proof of publication.

    SHA-256: 5a36f83cb7468e79109e7bbfd8048915c5eff4c2ec2007b2160f8baa8b38a5ef

    Open
  • Renon ECube 60AP operation and maintenance manual (rev 1.0, Sep 10, 2025)Official · Renon Power · Official instruction manual · September 10, 2025 · PDF
    Source details
    Revision
    rev 1.0 Sep 10, 2025
    Revision date
    September 10, 2025

    Archived copy captured on 2026-10-29.

    Location: Section 1 General Part, page 1 as printed (PDF page 4); revision table, page 9 as printed (PDF page 12)

    Retrieved Oct 29, 2026

    Renon Power's own 15-page operation and maintenance manual for the ECube 60AP battery energy storage system. Its revision table (page 9 as printed, PDF page 12) prints revision 1.0, Sep 10, 2025, "Initial version"; the cover says 2025 1ST EDITION and the file name says A01, which is not read as the revision. Kept as printed: the cover prints the model R-EC060050A1-US, while section 1 (page 1 as printed, PDF page 4) says the manual applies to "Product Model: R-EC060030A1/R-EC060060A1-US". It is bound only to the record whose exact code it prints in that scope line. Maintenance guidance, not a specification sheet. Served from Renon's own site. Manufacturer claims, not independent tests.

    Archived copies

    Archived copy of a document published by Renon Power. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].

    Archived backuprev 1.0 Sep 10, 2025 · 1.60 MB

    Archived copy, unaltered, kept as a record of what Renon Power published. Original address: https://www.renonpower.com/uploadfile/2025/1106/Operation-and-Maintenance-Manual-Ecube-60AP-US-A01.pdf. Copyright and takedown

    Source first found
    This copy captured
    Archived
    File detailsOriginal source
    Embedded creation date
    Embedded modification date
    Pages
    15

    Embedded dates are file metadata, not independent proof of publication.

    SHA-256: cb52aae7f291d7666f8e0bd27041b7820f44860740b9f1932e08e9bfbfb82307

    Open

Archived documents

Renon ECube 60AP US datasheet

Archived copy of a document published by Renon Power. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].

Archived backupRevision not recorded · 3.55 MB

Archived copy, unaltered, kept as a record of what Renon Power published. Original address: https://www.renonpower.com/uploadfile/2025/1114/RN-ECube-60AP-US.pdf. Copyright and takedown

Source first found
This copy captured
Archived
File detailsOriginal source
Embedded creation date
Embedded modification date
Pages
6

Embedded dates are file metadata, not independent proof of publication.

SHA-256: 5a36f83cb7468e79109e7bbfd8048915c5eff4c2ec2007b2160f8baa8b38a5ef

Renon ECube 60AP-US installation manual (2025, 6th edition)

Archived copy of a document published by Renon Power. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].

Archived backup2025 6th edition · 5.66 MB

Archived copy, unaltered, kept as a record of what Renon Power published. Original address: https://www.renonpower.com/uploadfile/2025/1231/Installation-Manual-ECube-60AP-US.pdf. Copyright and takedown

Source first found
This copy captured
Archived
File detailsOriginal source
Embedded creation date
Embedded modification date
Pages
25

Embedded dates are file metadata, not independent proof of publication.

SHA-256: aca4e5333b611f219cc7a107e52c234a83becdcdd8d2471cea6261ae93891aec

Renon ECube 60AP-US technical agreement (A04, 2025 4th edition)

Archived copy of a document published by Renon Power. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].

Archived backupA04 (2025 4th edition) · 2.32 MB

Archived copy, unaltered, kept as a record of what Renon Power published. Original address: https://www.renonpower.com/uploadfile/2025/1106/Technical-Agreement-ECube-60AP-US-A04.pdf. Copyright and takedown

Source first found
This copy captured
Archived
File detailsOriginal source
Embedded creation date
Embedded modification date
Pages
24

Embedded dates are file metadata, not independent proof of publication.

SHA-256: 0f257298bf13629d32bc194b3bbc2d90f1e10042c5a9b6338e8ee974c99928fd

Renon ECube 60AP operation and maintenance manual (rev 1.0, Sep 10, 2025)

Archived copy of a document published by Renon Power. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].

Archived backuprev 1.0 Sep 10, 2025 · 1.60 MB

Archived copy, unaltered, kept as a record of what Renon Power published. Original address: https://www.renonpower.com/uploadfile/2025/1106/Operation-and-Maintenance-Manual-Ecube-60AP-US-A01.pdf. Copyright and takedown

Source first found
This copy captured
Archived
File detailsOriginal source
Embedded creation date
Embedded modification date
Pages
15

Embedded dates are file metadata, not independent proof of publication.

SHA-256: cb52aae7f291d7666f8e0bd27041b7820f44860740b9f1932e08e9bfbfb82307

Submit a document

Parts and accessories

No sourced accessories or replacement parts listed yet.

Model history

Model identity

Model
R-EC060060A1-US
Published model / SKU
ECube 60AP [1]

Manufacturer SKU R-EC060060A1-US · US market

  1. Observed Oct 23, 2026

    UL 9540: claimed

    Product / system scope unresolved. Listed on the California Energy Commission Energy Storage System List (data unchanged since October 21, 2026; downloaded October 23, 2026) as Renon Power Technology Inc "R-EC060060A1-US": UL 9540, certifying entity TUV Rheinland of North America, certificate date 2025-08-14, Ed. 3 : 2023, CEC listing date 2026-02-11. A state equipment list entry, not the certification body's own record.

    [3]

  2. Observed Oct 11, 2026

    CEC: claimed

    Product / system scope unresolved. Model R-EC060060A1-US listed on the California Energy Commission Energy Storage System List (data unchanged since October 1, 2026; downloaded October 11, 2026) under Renon Power Technology Inc, as "R-EC060060A1-US", CEC listing date 2026-02-11. This is an equipment listing, not UL certification or complete-system approval.

    [2]

  3. Observed Oct 1, 2026

    UL 1973: claimed

    Battery pack claim; verification pending. A manufacturer claim, not a listing or certificate. Printed as "ANSI/CAN/UL 1973:2022" in the "Certification (Battery)" row ("ANSI/CAN/UL 1973:2022 ANSI/CAN/UL 9540:2020 UL 9540A, FCC Part 15 Subpart B:2023", read from the printed layout; the inverter row follows separately) of the General Parameters table for Product Model R-EC060060A1-US ("Product Parameter (For 480V Application)", page 5) in Renon's ECube 60AP US datasheet, captured October 1, 2026. The datasheet does not say which module or cabinet assembly was certified. No issuer, certificate or report number is printed; the issuer's record was not checked.

    [1]

  4. Observed Oct 1, 2026

    UL 9540A: claimed

    Battery pack claim; verification pending. A manufacturer claim, not a test report. Printed as "UL 9540A" in the "Certification (Battery)" row ("ANSI/CAN/UL 1973:2022 ANSI/CAN/UL 9540:2020 UL 9540A, FCC Part 15 Subpart B:2023", read from the printed layout; the inverter row follows separately) of the General Parameters table for Product Model R-EC060060A1-US ("Product Parameter (For 480V Application)", page 5) in Renon's ECube 60AP US datasheet, captured October 1, 2026. UL 9540A is a fire test method, not a certification; no test level, laboratory or report number is printed and no report was checked.

    [1]

Other recorded fields

FieldValueConditionsSource
Evidence breakdown
method version: 0.21-personal
documented pct: 85
basis: usable
missing:
Warranty energy disclosure evidence needed
Cell model disclosure evidence needed
criteria:
key: certificateEvidence
label: Certificates
value: 100
unit: evidence points
shown: CEC · UL 9540 +2
shown detail: CEC listed
state: verified
points: 45
ceiling: 45
weight: 45
share: 100
covered: yes
missing: no
folded: no
reason: Unknown
reason text: Unknown
note: CEC listing: full credit for the certificate criterion. Exact model found in the dated CEC equipment list. This is not a safety certification or system approval. Applies: CEC; UL 9540; UL 1973.
display note: Unknown
Sources: [2] [3]
key: years
label: Warranty term
value: 10
unit: years
shown: 10 years
shown detail: Unknown
state: documented
points: 13.33
ceiling: 20
weight: 20
share: 66.7
covered: yes
missing: no
folded: no
reason: Unknown
reason text: Unknown
note:
display note: Unknown
Sources: [1]
key: throughputEvidence
label: Warranty energy disclosure
value: 0
unit: evidence points
shown: Research pending
shown detail: Unknown
state: pending
points: 0
ceiling: 10
weight: 10
share: 0
covered: no
missing: yes
folded: yes
reason: Unknown
reason text: Unknown
note: No qualifying quantified warranty energy recorded. This is an evidence gap, not a performance judgment.
display note: Unknown
Sources: No source on record
key: lifetime
label: Lifetime / capacity
value: Unknown
unit: MWh/kWh
shown: 8,000 cycles
shown detail: Unknown
state: documented
points: 4
ceiling: 20
weight: 20
share: Unknown
covered: yes
missing: no
folded: no
reason: Unknown
reason text: Unknown
note: Documented cycle rating earns 20% of this criterion. More evidence is needed to compare lifetime MWh per kWh.
display note: Unknown
Sources: [1]
key: cellDisclosure
label: Cell model disclosure
value: 0
unit: disclosure points
shown: Research pending
shown detail: Unknown
state: pending
points: 0
ceiling: 5
weight: 5
share: 0
covered: no
missing: yes
folded: yes
reason: Unknown
reason text: Unknown
note: A sourced cell manufacturer and model are needed. Grade A, chemistry and cell capacity alone do not identify a cell model.
display note: Unknown
Sources: No source on record

Community discussions

No discussions linked yet. Search DIY Solar Forum

Sources

  1. Renon ECube 60AP US datasheet (Renon Power · manufacturer · observed Oct 1, 2026)
  2. CEC Energy Storage System List, official spreadsheet (data unchanged since October 1, 2026; downloaded October 11, 2026) (California Energy Commission · government equipment registry · Data unchanged since October 1, 2026 · observed Oct 10, 2026 · effective Oct 1, 2026)
  3. CEC Energy Storage System List, official spreadsheet (data unchanged since October 21, 2026; downloaded October 23, 2026) (California Energy Commission · government equipment registry · Data unchanged since October 21, 2026 · observed Oct 23, 2026 · effective Oct 21, 2026)

Sign in to report an error on this page