conditions: Renogy's own product data, captured 2026-10-27, prints SKU "RBT12100LFP-H-US" for option "1 Pack" (variant 43178667442291) of listing "Mini Size 12V 100Ah DuoHeat Tech Lithium Iron Phosphate Battery"; the same SKU is also printed on 1 other listing option(s) for the same single unit.
Printed as "Battery Cell Type Lithium Iron Phosphate" in the Renogy user manual for RBT12100LFP-H linked from the US store product page, PDF page 21, captured on October 13, 2026.
Where: The Renogy user manual for RBT12100LFP-H linked from the US store product page, PDF page 21
Printed as "Terminal Bolt Size M8 x 1.25 x 12 mm" in the Renogy user manual for RBT12100LFP-H linked from the US store product page, PDF page 21, captured on October 13, 2026.
Where: The Renogy user manual for RBT12100LFP-H linked from the US store product page, PDF page 21
Printed as "Terminal Bolt Size M8 x 1.25 x 12 mm" in the Renogy user manual for RBT12100LFP-H linked from the US store product page, PDF page 21, captured on October 13, 2026.
Where: The Renogy user manual for RBT12100LFP-H linked from the US store product page, PDF page 21
Charged Reviews classified this product from the documents it is based on. It is our own grouping, not a manufacturer claim.
Printed as "The RENOGY Core Series 12.8V 100Ah Mini Lithium Iron Phosphate Battery w/Self-heating Function is designed for the drop-in replacement of deep-cycle lead-acid batteries with its standard Battery Council International (BCI) group size (G22NF).". Classified as Case battery from the maker's own words for this model.
Location: User manual, RENOGY Core Series 12.8V 100Ah Mini Lithium Iron Phosphate Battery w/Self-heating Function RBT12100LFP-H (version A0, November 25, 2024), PDF page 5, Introduction
Enclosure rating
IP65
Printed as "Protection Rating IP65" in the Renogy user manual for RBT12100LFP-H linked from the US store product page, PDF page 21, captured on October 13, 2026.
Where: The Renogy user manual for RBT12100LFP-H linked from the US store product page, PDF page 21
Printed as "Connection Method Series & Parallel (4S4P)" in the Renogy user manual for RBT12100LFP-H linked from the US store product page, PDF page 21, captured on October 13, 2026.
Where: The Renogy user manual for RBT12100LFP-H linked from the US store product page, PDF page 21, specifications
Printed as "Maximum Continuous Charge Current 100A" in the Renogy user manual for RBT12100LFP-H linked from the US store product page, PDF page 21, captured on October 13, 2026.
Where: The Renogy user manual for RBT12100LFP-H linked from the US store product page, PDF page 21
Printed as "Peak Discharge Current 300A@10s" in the Renogy user manual for RBT12100LFP-H linked from the US store product page, PDF page 21, captured on October 13, 2026.
Where: The Renogy user manual for RBT12100LFP-H linked from the US store product page, PDF page 21
Printed as "You can connect up to 8 batteries in parallel or 4 batteries in series." in the Renogy user manual for RBT12100LFP-H linked from the US store product page, PDF page 13, captured on October 13, 2026.
Where: The Renogy user manual for RBT12100LFP-H linked from the US store product page, PDF page 13
Printed as "The standard charging process for the battery involves charging at a constant current of 50A" in the Renogy user manual for RBT12100LFP-H linked from the US store product page, PDF page 17, captured on October 13, 2026.
Where: The Renogy user manual for RBT12100LFP-H linked from the US store product page, PDF page 17
Battery, user manual, two insulating sleeves, two long terminal bolts (M8*1.25*12 mm)
Printed as "Insulating Sleeve × 2"; "User Manual × 1 Long Terminal Bolt × 2 M8*1.25*12 mm" in the Renogy user manual for RBT12100LFP-H linked from the US store product page, PDF page 6, captured on October 13, 2026.
Where: The Renogy user manual for RBT12100LFP-H linked from the US store product page, PDF page 6
Printed as "Connection Method Series & Parallel (4S4P)" in the Renogy user manual for RBT12100LFP-H linked from the US store product page, PDF page 21, captured on October 13, 2026.
Where: The Renogy user manual for RBT12100LFP-H linked from the US store product page, PDF page 21, specifications
Printed as "53.1 inch·lbs to 70.8 inch·lbs / 6 N·m to 8 N·m" in the Renogy user manual for RBT12100LFP-H linked from the US store product page, PDF page 21, captured on October 13, 2026.
Where: The Renogy user manual for RBT12100LFP-H linked from the US store product page, PDF page 21
Printed as "Maximum Continuous Discharge Current 100A" in the Renogy user manual for RBT12100LFP-H linked from the US store product page, PDF page 21, captured on October 13, 2026.
Where: The Renogy user manual for RBT12100LFP-H linked from the US store product page, PDF page 21
Printed as "Voltage Range 10V to 14.6V" in the Renogy user manual for RBT12100LFP-H linked from the US store product page, PDF page 21, captured on October 13, 2026.
Where: The Renogy user manual for RBT12100LFP-H linked from the US store product page, PDF page 21
Printed as "-22°F to 131°F (-30°C to 55°C)"; "-30°C to 55°C" in the Renogy user manual for RBT12100LFP-H linked from the US store product page, PDF page 21, captured on October 13, 2026.
Where: The Renogy user manual for RBT12100LFP-H linked from the US store product page, PDF page 21
Printed as "once the battery temperature drops below 41°F (5°C)" in the Renogy user manual for RBT12100LFP-H linked from the US store product page, PDF page 18, captured on October 13, 2026.
Where: The Renogy user manual for RBT12100LFP-H linked from the US store product page, PDF page 18
Bottom recommended; may be mounted on any side except the top (terminal side)
Printed as "We recommend installing the battery on the bottom."; "you can also mount it on all sides of the battery except the top side" in the Renogy user manual for RBT12100LFP-H linked from the US store product page, PDF page 9, captured on October 13, 2026.
Where: The Renogy user manual for RBT12100LFP-H linked from the US store product page, PDF page 9
Printed as "It is recommended that a single 12.8V 100Ah battery should be charged at 50A" in the Renogy user manual for RBT12100LFP-H linked from the US store product page, PDF page 17, captured on October 13, 2026.
Where: The Renogy user manual for RBT12100LFP-H linked from the US store product page, PDF page 17
Printed as "During standard discharging, the battery is discharged at a constant current of 50A" in the Renogy user manual for RBT12100LFP-H linked from the US store product page, PDF page 18, captured on October 13, 2026.
Where: The Renogy user manual for RBT12100LFP-H linked from the US store product page, PDF page 18
Printed as "-4°F to 113°F (-20°C to 45°C)" in the Renogy user manual for RBT12100LFP-H linked from the US store product page, PDF page 21, captured on October 13, 2026.
Where: The Renogy user manual for RBT12100LFP-H linked from the US store product page, PDF page 21
Printed as "Overvoltage Disconnect 15.0V" in the Renogy user manual for RBT12100LFP-H linked from the US store product page, PDF page 17, captured on October 13, 2026.
Where: The Renogy user manual for RBT12100LFP-H linked from the US store product page, PDF page 17
Printed as "-4°F to 140°F (-20°C to 60°C)" in the Renogy user manual for RBT12100LFP-H linked from the US store product page, PDF page 21, captured on October 13, 2026.
Where: The Renogy user manual for RBT12100LFP-H linked from the US store product page, PDF page 21
Printed as "Undervoltage Shutdown 10.0V" in the Renogy user manual for RBT12100LFP-H linked from the US store product page, PDF page 17, captured on October 13, 2026.
Where: The Renogy user manual for RBT12100LFP-H linked from the US store product page, PDF page 17
Printed as "Charge Voltage 14.6V" in the Renogy user manual for RBT12100LFP-H linked from the US store product page, PDF page 21, captured on October 13, 2026.
Where: The Renogy user manual for RBT12100LFP-H linked from the US store product page, PDF page 21
6.73 L* (Calculated enclosure volume: W × H × D in mm ÷ 1,000,000)W: 138 × H: 213 × L: 229 mm / W: 5.43 × H: 8.39 × L: 9.02 in9.7 kg / 21 lb
Evidence score
9/100Missing details40% documented
The Evidence score uses the priorities you choose. It counts published documents, such as certificates and warranty terms, and it compares a documented figure with the best documented figure of the same kind. It does not count owner reviews, and it is not a verdict on product quality or on how many people have reviewed it. A low score can mean little is documented, or that a documented figure is below the best of its kind. Undisclosed data scores 0.
Missing details. This number counts only the evidence recorded so far. The source review for this product is not finished, or the maker has not disclosed enough, so the number can only go up.
Missing for this product: Certificates evidence needed; Warranty energy disclosure evidence needed; Cell model disclosure evidence needed.
12 V · Case battery · Rated capacity
The warranty term and the lifetime energy are each scored against the best documented value for a home storage battery: a value earns its share of that best, times the weight. A documented value always earns points; an undisclosed one earns 0.
Printed as "Material and Workmanship Warranty 5-year prorated material and workmanship warranty" on the RBT12100LFP-H-US product page, captured on September 25, 2026.
Research pending, 0 points: Certificates, Warranty energy disclosure, Cell model disclosure.
Computed from public specifications and evidence records. Warranty duration is not service quality; certificate evidence points are not a safety rating. Compatibility and installation limits still apply.
What this shows: what each record says and how far it reaches. It does not mean the product is approved.
Unknown: no certification evidence recorded in this data.
Warranty
Field
Value
Conditions
Source
Remedy
Repair, or replacement with a new or refurbished product, at Renogy's option; refund if it cannot repair or replace
Printed as "Renogy will, at its option, either repair the defective product or replace it with a new or refurbished product of equal or greater performance and reliability." in the Renogy Limited Warranty (RNG-4-243, rev. A7), Page 1, Limited Warranty for All, captured on September 26, 2026. Batteries also carry the prorated replacement table: "0-12 Months No Charge" and a charge after 12 months.
Original purchaser only; if gifted or resold, the claim goes through the original purchaser
Printed as "This warranty extends only to the original Purchaser. If gifted or resold the customer must go through the original Purchaser in order to claim warranty." in the Renogy Limited Warranty (RNG-4-243, rev. A7), General Conditions for Warranty Claims, captured on September 26, 2026.
Excludes normal wear and tear, improper installation, operation and storage, unauthorized repair or modification, misuse, surges and force majeure; the invoice and a written claim within the term are required
Printed as "The warranty does not cover failures and damages that result from normal wear and tear, improper installation, operation, and storage" in the Renogy Limited Warranty (RNG-4-243, rev. A7), Exclusions and Limitations, captured on September 26, 2026.
Printed as "The warranty is in effect from the date of purchase by the user" in the Renogy Limited Warranty (RNG-4-243, rev. A7), Page 1, Limited Warranty for All, captured on September 26, 2026.
Printed as "Material and Workmanship Warranty 5-year prorated material and workmanship warranty" on the RBT12100LFP-H-US product page, captured on September 25, 2026.
Labor not covered; returns for valid warranty service ship at the warrantor's expense and risk
Printed as "This warranty does not cover labor." in the Renogy Limited Warranty (RNG-4-243, rev. A7), General Conditions for Warranty Claims and Exclusions and Limitations, captured on September 26, 2026.
Where: General Conditions for Warranty Claims and Exclusions and Limitations
Renogy's user manual for the RBT12100LFP-H, the file Renogy's US store (www.renogy.com) product page for RBT12100LFP-H-US links as its manual, captured on October 13, 2026. Manufacturer instructions and specifications, not independent tests.
Archived copies
Archived copy of a document published by Renogy. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Renogy company-wide limited warranty schedule covering all product families; it does not state electrical or mechanical specifications for any individual SKU.
Archived copies
Archived copy of a document published by Renogy. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Captured by scripts/prepare-brand-sweep-sep21.mjs on 2026-09-25.
Location: Identity block and Specs tab
Retrieved Sep 24, 2026
Renogy's own product page on renogy.com (its Shopify store), captured on September 25, 2026. The page's identity block prints the stock keeping unit RBT12100LFP-H-US and its Specs tab prints the manufacturer's specification table. A manufacturer claim; it does not establish independent test results.
Archived copy of a document published by Renogy. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
User manual, RENOGY Core Series 12.8V 100Ah Mini Lithium Iron Phosphate Battery w/Self-heating Function RBT12100LFP-H (version A0, November 25, 2024)
Archived copy of a document published by Renogy. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
No sourced accessories or replacement parts listed yet.
Model history
Model identity
Model
RBT12100LFP-H-US
Manufacturer SKU RBT12100LFP-H-US · US market
No historical observations recorded yet.
Other recorded fields
Field
Value
Conditions
Source
Evidence breakdown
method version: 0.21-personal
documented pct: 40
basis: nominal
missing:
Certificates evidence needed
Warranty energy disclosure evidence needed
Cell model disclosure evidence needed
criteria:
key: certificateEvidence
label: Certificates
value: 0
unit: evidence points
shown: Research pending
shown detail: Unknown
state: pending
points: 0
ceiling: 45
weight: 45
share: 0
covered: no
missing: yes
folded: yes
reason: Unknown
reason text: Unknown
note: No qualifying applicable evidence recorded. This is not proof that certification is absent. Applies: UL 1973; CEC not applicable to 12 V / 24 V / 36 V DC modules; UL 9540 not applicable to 12 V / 24 V / 36 V DC modules.