Printed as "Terminal Bolt Size M8 x 1.25 x 12 mm" in the Renogy user manual for RBT12100LFP-H linked from the Canadian store product page, PDF page 21, captured on October 13, 2026.
Where: The Renogy user manual for RBT12100LFP-H linked from the Canadian store product page, PDF page 21
Printed as "21.38 lbs / 9.7 kg"; "9.7 kg" in the Renogy user manual for RBT12100LFP-H linked from the Canadian store product page, PDF page 7, captured on October 13, 2026.
Where: The Renogy user manual for RBT12100LFP-H linked from the Canadian store product page, PDF page 7
Printed as "Cycle Life (0.5C, 25°C) 5000 Cycles (80% DOD)" in the Renogy user manual for RBT12100LFP-H linked from the Canadian store product page, PDF page 21, captured on October 13, 2026.
Where: The Renogy user manual for RBT12100LFP-H linked from the Canadian store product page, PDF page 21
W 138 × H 213 × L 229 mm / W 5.43 × H 8.39 × L 9.02 in converted
Printed as "9.02 x 5.43 x 8.39 in / 229 x 138 x 213 mm" in the Renogy user manual for RBT12100LFP-H linked from the Canadian store product page, PDF page 21, captured on October 13, 2026.
Where: The Renogy user manual for RBT12100LFP-H linked from the Canadian store product page, PDF page 21
Printed as "Terminal Bolt Size M8 x 1.25 x 12 mm" in the Renogy user manual for RBT12100LFP-H linked from the Canadian store product page, PDF page 21, captured on October 13, 2026.
Where: The Renogy user manual for RBT12100LFP-H linked from the Canadian store product page, PDF page 21
Printed as "Protection Rating IP65" in the Renogy user manual for RBT12100LFP-H linked from the Canadian store product page, PDF page 21, captured on October 13, 2026.
Where: The Renogy user manual for RBT12100LFP-H linked from the Canadian store product page, PDF page 21
Printed as "Connection Method Series & Parallel (4S4P)" in the Renogy user manual for RBT12100LFP-H linked from the Canadian store product page, PDF page 21, captured on October 13, 2026.
Where: The Renogy user manual for RBT12100LFP-H linked from the Canadian store product page, PDF page 21, specifications
Printed as "Maximum Continuous Charge Current 100A" in the Renogy user manual for RBT12100LFP-H linked from the Canadian store product page, PDF page 21, captured on October 13, 2026.
Where: The Renogy user manual for RBT12100LFP-H linked from the Canadian store product page, PDF page 21
Printed as "300A@10s" in the Renogy user manual for RBT12100LFP-H linked from the Canadian store product page, PDF page 21, captured on October 13, 2026.
Where: The Renogy user manual for RBT12100LFP-H linked from the Canadian store product page, PDF page 21
Printed as "Peak Discharge Current 300A@10s" in the Renogy user manual for RBT12100LFP-H linked from the Canadian store product page, PDF page 21, captured on October 13, 2026.
Where: The Renogy user manual for RBT12100LFP-H linked from the Canadian store product page, PDF page 21
Printed as "You can connect up to 8 batteries in parallel or 4 batteries in series." in the Renogy user manual for RBT12100LFP-H linked from the Canadian store product page, PDF page 13, captured on October 13, 2026.
Where: The Renogy user manual for RBT12100LFP-H linked from the Canadian store product page, PDF page 13
Printed as "The standard charging process for the battery involves charging at a constant current of 50A" in the Renogy user manual for RBT12100LFP-H linked from the Canadian store product page, PDF page 17, captured on October 13, 2026.
Where: The Renogy user manual for RBT12100LFP-H linked from the Canadian store product page, PDF page 17
Battery, user manual, two insulating sleeves, two long terminal bolts (M8*1.25*12 mm)
Printed as "Insulating Sleeve × 2"; "User Manual × 1 Long Terminal Bolt × 2 M8*1.25*12 mm" in the Renogy user manual for RBT12100LFP-H linked from the Canadian store product page, PDF page 6, captured on October 13, 2026.
Where: The Renogy user manual for RBT12100LFP-H linked from the Canadian store product page, PDF page 6
Printed as "Connection Method Series & Parallel (4S4P)" in the Renogy user manual for RBT12100LFP-H linked from the Canadian store product page, PDF page 21, captured on October 13, 2026.
Where: The Renogy user manual for RBT12100LFP-H linked from the Canadian store product page, PDF page 21, specifications
Printed as "53.1 inch·lbs to 70.8 inch·lbs / 6 N·m to 8 N·m" in the Renogy user manual for RBT12100LFP-H linked from the Canadian store product page, PDF page 21, captured on October 13, 2026.
Where: The Renogy user manual for RBT12100LFP-H linked from the Canadian store product page, PDF page 21
Printed as "Maximum Continuous Discharge Current 100A" in the Renogy user manual for RBT12100LFP-H linked from the Canadian store product page, PDF page 21, captured on October 13, 2026.
Where: The Renogy user manual for RBT12100LFP-H linked from the Canadian store product page, PDF page 21
Printed as "Voltage Range 10V to 14.6V" in the Renogy user manual for RBT12100LFP-H linked from the Canadian store product page, PDF page 21, captured on October 13, 2026.
Where: The Renogy user manual for RBT12100LFP-H linked from the Canadian store product page, PDF page 21
Printed as "-22°F to 131°F (-30°C to 55°C)"; "-30°C to 55°C" in the Renogy user manual for RBT12100LFP-H linked from the Canadian store product page, PDF page 21, captured on October 13, 2026.
Where: The Renogy user manual for RBT12100LFP-H linked from the Canadian store product page, PDF page 21
Printed as "once the battery temperature drops below 41°F (5°C)" in the Renogy user manual for RBT12100LFP-H linked from the Canadian store product page, PDF page 18, captured on October 13, 2026.
Where: The Renogy user manual for RBT12100LFP-H linked from the Canadian store product page, PDF page 18
Bottom recommended; may be mounted on any side except the top (terminal side)
Printed as "We recommend installing the battery on the bottom."; "you can also mount it on all sides of the battery except the top side" in the Renogy user manual for RBT12100LFP-H linked from the Canadian store product page, PDF page 9, captured on October 13, 2026.
Where: The Renogy user manual for RBT12100LFP-H linked from the Canadian store product page, PDF page 9
Printed as "It is recommended that a single 12.8V 100Ah battery should be charged at 50A" in the Renogy user manual for RBT12100LFP-H linked from the Canadian store product page, PDF page 17, captured on October 13, 2026.
Where: The Renogy user manual for RBT12100LFP-H linked from the Canadian store product page, PDF page 17
Printed as "During standard discharging, the battery is discharged at a constant current of 50A" in the Renogy user manual for RBT12100LFP-H linked from the Canadian store product page, PDF page 18, captured on October 13, 2026.
Where: The Renogy user manual for RBT12100LFP-H linked from the Canadian store product page, PDF page 18
Printed as "-4°F to 113°F (-20°C to 45°C)" in the Renogy user manual for RBT12100LFP-H linked from the Canadian store product page, PDF page 21, captured on October 13, 2026.
Where: The Renogy user manual for RBT12100LFP-H linked from the Canadian store product page, PDF page 21
Printed as "Overvoltage Disconnect 15.0V" in the Renogy user manual for RBT12100LFP-H linked from the Canadian store product page, PDF page 17, captured on October 13, 2026.
Where: The Renogy user manual for RBT12100LFP-H linked from the Canadian store product page, PDF page 17
Printed as "-4°F to 140°F (-20°C to 60°C)" in the Renogy user manual for RBT12100LFP-H linked from the Canadian store product page, PDF page 21, captured on October 13, 2026.
Where: The Renogy user manual for RBT12100LFP-H linked from the Canadian store product page, PDF page 21
Printed as "Undervoltage Shutdown 10.0V" in the Renogy user manual for RBT12100LFP-H linked from the Canadian store product page, PDF page 17, captured on October 13, 2026.
Where: The Renogy user manual for RBT12100LFP-H linked from the Canadian store product page, PDF page 17
Printed as "Charge Voltage 14.6V" in the Renogy user manual for RBT12100LFP-H linked from the Canadian store product page, PDF page 21, captured on October 13, 2026.
Where: The Renogy user manual for RBT12100LFP-H linked from the Canadian store product page, PDF page 21
6.73 L* (Calculated enclosure volume: W × H × D in mm ÷ 1,000,000)W: 138 × H: 213 × L: 229 mm / W: 5.43 × H: 8.39 × L: 9.02 in9.7 kg / 21 lb
Evidence score
4/100Missing details20% documented
The Evidence score uses the priorities you choose. It counts published documents, such as certificates and warranty terms, and it compares a documented figure with the best documented figure of the same kind. It does not count owner reviews, and it is not a verdict on product quality or on how many people have reviewed it. A low score can mean little is documented, or that a documented figure is below the best of its kind. Undisclosed data scores 0.
Missing details. This number counts only the evidence recorded so far. The source review for this product is not finished, or the maker has not disclosed enough, so the number can only go up.
Missing for this product: Certificates evidence needed; Warranty term needed; Warranty energy disclosure evidence needed; Cell model disclosure evidence needed.
12 V · Format not recorded · Rated capacity
The warranty term and the lifetime energy are each scored against the best documented value for a home storage battery: a value earns its share of that best, times the weight. A documented value always earns points; an undisclosed one earns 0.
Lifetime / capacity5,000 cycles4 / 20
Cycle rating disclosed · 20% weight
Documented cycle rating earns 20% of this criterion. More evidence is needed to compare lifetime MWh per kWh.
Research pending, 0 points: Certificates, Warranty term, Warranty energy disclosure, Cell model disclosure.
Computed from public specifications and evidence records. Warranty duration is not service quality; certificate evidence points are not a safety rating. Compatibility and installation limits still apply.
What this shows: what each record says and how far it reaches. It does not mean the product is approved.
Unknown: no certification evidence recorded in this data.
Warranty
Field
Value
Conditions
Source
Remedy
Repair, or replacement with a new or refurbished product, as the warrantor decides after its technical support team's assessment; a refund if Renogy cannot repair or replace; batteries carry a prorated replacement charge after 12 months
Summarized from Renogy Limited Warranty (RNG-4-243, rev. A6) linked from the Canadian store, captured on October 13, 2026, which prints "the Warrantor will either repair or replace the defective product(s) with a new or refurbished product(s)." "If for any reason Renogy is unable to repair or replace the defective product(s) then a refund can occur." "0-12 Months No Charge". Renogy's Canadian store product page for RBT12100LFP-H-CA links this document.
Where: Page 1, opening paragraph and Part 1, Prorated Warranty table
Original purchaser only; if gifted or resold, the claim goes through the original purchaser, and original order information is needed
Summarized from Renogy Limited Warranty (RNG-4-243, rev. A6) linked from the Canadian store, captured on October 13, 2026, which prints "This warranty extends only to the original Purchaser. If gifted or resold the customer must go through the original Purchaser in order to claim warranty." "Original order information is needed to claim warranty.". Renogy's Canadian store product page for RBT12100LFP-H-CA links this document.
Excludes normal wear and tear, improper installation, operation and storage, unauthorized repair or modification, misuse, unusual electrical stress, extreme temperatures and force majeure; failure to install or operate the battery properly voids the warranty
Summarized from Renogy Limited Warranty (RNG-4-243, rev. A6) linked from the Canadian store, captured on October 13, 2026, which prints "The warranty does not cover failures and damages that result from normal wear and tear, improper installation, operation, and storage" "Failure to properly install or operate the battery will void the warranty.". Renogy's Canadian store product page for RBT12100LFP-H-CA links this document.
Where: Part 1, Prorated Warranty note and section 3, Exclusions and Limitations for Batteries
Summarized from Renogy Limited Warranty (RNG-4-243, rev. A6) linked from the Canadian store, captured on October 13, 2026, which prints "The warranty is in effect from the date of purchase by the user". Renogy's Canadian store product page for RBT12100LFP-H-CA links this document.
Labor not covered; products returned for valid warranty service ship at the warrantor's expense and risk
Summarized from Renogy Limited Warranty (RNG-4-243, rev. A6) linked from the Canadian store, captured on October 13, 2026, which prints "This warranty does not cover labor." "Any product(s) returned for valid warranty service shall be shipped at the expense and risk of the Warrantor.". Renogy's Canadian store product page for RBT12100LFP-H-CA links this document.
Renogy's user manual for the RBT12100LFP-H, the file Renogy's Canadian store (ca.renogy.com) product page for RBT12100LFP-H-CA links as its manual, captured on October 13, 2026. Manufacturer instructions and specifications, not independent tests.
Archived copies
Archived copy of a document published by Renogy. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Renogy's warranty statement as linked from its Canadian store (ca.renogy.com) product pages, captured on October 13, 2026. A store-wide policy: it sets the warranty terms for the products that store sells; the term in years is taken from each product page. Manufacturer statement.
Archived copies
Archived copy of a document published by Renogy. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Renogy's Canadian store page for the cold-weather battery bundle listing, captured September 29, 2026, with SKU RBT12100LFP-H-CA as the default (first-shown) option (12V 100Ah Mini, Heated). The page also sells RBT12100LFP-BT-CA and RBT12120LFP-SBH-CA (built separately) as other options on the same listing. It prints only qualitative key features ("Faster Access to Power", "Warmth at the Right Time", etc.), not a numeric specification table, and links no manual for this option. A candidate dedicated page (core-mini-12v-100ah-lifepo4-battery-with-duoheat-tech) answered HTTP 500 on September 29, 2026 and was not retried. Manufacturer claims, not independent tests.
Earlier revisions, archived captures and copies published by someone other than the manufacturer. Every one stays reachable.
Archived documents
Renogy user manual for RBT12100LFP-H, as linked from the Canadian store product page (12V_20100Ah_20Self-Heating_20Mini_20Battery_20UM.pdf, October 13, 2026 capture)
Archived copy of a document published by Renogy. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Renogy Limited Warranty (RNG-4-243, rev. A6) linked from the Canadian store (October 13, 2026 capture)
Archived copy of a document published by Renogy. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
No sourced accessories or replacement parts listed yet.
Model history
Model identity
Model
RBT12100LFP-H
Manufacturer SKU RBT12100LFP-H-CA · CA market
No historical observations recorded yet.
Other recorded fields
Field
Value
Conditions
Source
Evidence breakdown
method version: 0.21-personal
documented pct: 20
basis: nominal
missing:
Certificates evidence needed
Warranty term needed
Warranty energy disclosure evidence needed
Cell model disclosure evidence needed
criteria:
key: certificateEvidence
label: Certificates
value: 0
unit: evidence points
shown: Research pending
shown detail: Unknown
state: pending
points: 0
ceiling: 45
weight: 45
share: 0
covered: no
missing: yes
folded: yes
reason: Unknown
reason text: Unknown
note: No qualifying applicable evidence recorded. This is not proof that certification is absent. Applies: UL 1973; CEC not applicable to 12 V / 24 V / 36 V DC modules; UL 9540 not applicable to 12 V / 24 V / 36 V DC modules.
display note: Unknown
Sources: No source on record
key: years
label: Warranty term
value: Unknown
unit: years
shown: Research pending
shown detail: Unknown
state: pending
points: 0
ceiling: 20
weight: 20
share: Unknown
covered: no
missing: yes
folded: yes
reason: undocumented
reason text: Not documented. Undisclosed data scores 0.
note: Not documented.
display note: Unknown
Sources: No source on record
key: throughputEvidence
label: Warranty energy disclosure
value: 0
unit: evidence points
shown: Research pending
shown detail: Unknown
state: pending
points: 0
ceiling: 10
weight: 10
share: 0
covered: no
missing: yes
folded: yes
reason: Unknown
reason text: Unknown
note: No qualifying quantified warranty energy recorded. This is an evidence gap, not a performance judgment.
display note: Unknown
Sources: No source on record
key: lifetime
label: Lifetime / capacity
value: Unknown
unit: MWh/kWh
shown: 5,000 cycles
shown detail: Unknown
state: documented
points: 4
ceiling: 20
weight: 20
share: Unknown
covered: yes
missing: no
folded: no
reason: Unknown
reason text: Unknown
note: Documented cycle rating earns 20% of this criterion. More evidence is needed to compare lifetime MWh per kWh.