Charged ReviewsSaved 0Compare 0Login

Charged Reviews · Quick reference

RELiON RB24V52

Brand
RELiON
Model
RB24V52
SKU / part number
RB24V52 [1]
Category
Batteries

chargedreviews.com/batteries/relion-rb24v52

Energy and chemistry

Nominal voltage
25.6 V [1]
Rated capacity
52 Ah [1]
Nominal energy
1.331 kWh Needs confirmation [2]
Usable energy
?
Chemistry
Cylindrical - LiFePO4 [1]
Cell format
?

Charge and discharge

Continuous charge current
50 A [2]
Continuous discharge current
50 A [2]
Maximum charge current
50 A [1]
Maximum discharge current
50 A [1]
Peak charge current
?
Peak discharge current
100 A [1]
Continuous output power
?
Peak output
?
Charge cutoff voltage
31.2 V [2]
Discharge cutoff voltage
16 V [1]

BMS and communication

BMS continuous current
?
Communication protocols
?
Wireless monitoring
?
Inverter compatibility
?

Operating temperature

Charging temperature
-20 to 45 °C / -4 to 113 °F converted [1]
Discharging temperature
-20 to 60 °C / -4 to 140 °F converted [1]
Storage temperature
-5 to 35 °C / 23 to 95 °F converted [1]
Self-heating
?

Mechanical and mounting

Dimensions
W 329 × H 214 × D 172 mm / W 13 × H 8.43 × D 6.77 in converted [1]
Weight
13.2 kg / 29.1 lb converted [1]
Terminals
M8 x 1.25 [1]
Mounting / format
case [1]
Enclosure rating (IP)
IP67 [2]

Installation (from the manual)

Torque

Main terminal torque
9 to 11 N·m [2]
Communication terminal torque
?
Ground terminal torque
?

Not in the manual: Conductors, Protection, Clearances and orientation, Grounding, Communication

System limits

Maximum parallel units
?
Series connection
1 [1]
Maximum system energy
?
Page 1 of 2 · Installation values · ? means nothing is recordedAggregated, often community-reported information, not official documentation. Do not rely on it for installation, purchase or compliance decisions; always confirm values with the manufacturer’s official documentation. Charged Reviews accepts no responsibility for errors.

Charged Reviews · Quick reference

RELiON RB24V52 · RB24V52

Warranty

Warranty term?
Warranty cycle limit?
Warranted throughput?
Capacity retention?
Cycle rating?
Estimated throughput?
Coverage starts?
Coverage conditions?
Remedy?
Labor and shipping?
Transfer to another owner?
Registration?

Certifications and listings

UL 1973?
UL 9540?
UL 9540A?
UN 38.3Claimed [1]
IEC 62619?
CE?
UL 1642Claimed [1]

Documents and sources

  1. RELiON product page for RB24V52 (Specifications panel) Manufacturer product page · Checked Sep 19, 2026 https://www.relionbattery.com/products/lithium/rb24v52
  2. RELiON RB24V52 data sheet Manufacturer datasheet (PDF) · Checked Sep 19, 2026 https://relion-battery.s3.us-east-1.amazonaws.com/docs/product/RELiON-Data-Sheet_RB24V52.pdf

Unofficial reference. Information may be incorrect. This sheet aggregates the public sources listed above, much of it community-reported. It is not official manufacturer documentation, not an installation guide and not a compliance record. Community-reported values are checked against official manufacturer information before publication; we cannot guarantee accuracy or completeness. Do not rely on this sheet for installation, purchase or compliance decisions: always confirm every value with the manufacturer’s official documentation before buying, wiring or installing equipment. Charged Reviews accepts no responsibility for errors or omissions. Manufacturers can submit documents or corrections.

Page 2 of 2 · Charged Reviews LLC · chargedreviews.com/batteries/relion-rb24v52Some links pay us a commission. That does not affect what we record.