Pytes V16 16kWh

Brand
Pytes
Model
V16
SKU / part number
?
Category
Batteries

chargedreviews.com/batteries/pytes-v16

Energy and chemistry

Nominal voltage
51.2 V [1]
Rated capacity
314 Ah [1]
Nominal energy
16 kWh [1]
Usable energy
?
Chemistry
LiFePO4 [1]
Cell format
?

Charge and discharge

Continuous charge current
200 A [1]
Continuous discharge current
200 A [1]
Maximum charge current
?
Maximum discharge current
?
Peak charge current
?
Peak discharge current
200 A [2]
Continuous output power
?
Peak output
?
Maximum charge voltage
?
Charge cutoff voltage
?
Discharge cutoff voltage
?

BMS and communication

BMS continuous current
?
Communication protocols
CAN / RS485 / RS232 / Dry Contact / WiFi [1]
Wireless monitoring
V16 can be connected with LSW-5 WiFi Dongle. [2]
Inverter compatibility
?

Operating temperature

Charging temperature
0 to 55 °C / 32 to 131 °F converted [1]
Discharging temperature
-20 to 55 °C / -4 to 131 °F converted [1]
Storage temperature
-20 to 45 °C / -4 to 113 °F converted [2]
Self-heating
yes [1]

Mechanical and mounting

Dimensions
W 688.4 × H 700 × D 260 mm / W 27.1 × H 27.6 × D 10.2 in converted [1]
Weight
130.5 kg / 287.7 lb converted [1]
Terminals
Phoenix Plug & Play DC connector, model BPC 250 FT B 35-70 [3]
Mounting / format
Installed upright on a vertical, solid surface, such as a brick or concrete wall [2]
Enclosure rating (IP)
IP66 [1]

Installation (from the manual)

Conductors

Cable size
2/0 AWG (UL10269), 2 m positive and negative power cables included [2]

Clearances and orientation

Installation clearances
Minimum 0.5 meters away from inverter [2]
Mounting orientation
Upright [2]

Grounding

Grounding
Earthing cable included: 1000mm ground wire, UL1015, 10AWG, yellow-green [2]

Communication

Communication ports
Cascade Communication Ports (Port 1/0): RJ45 ports, connect Port 1 of the battery to Port 0 to the next battery; External Communication Port COM (CAN/RS485 protocol): RJ45 port, follow CAN & RS485 protocol, to connect to inverter and output system information; RS232 Console Port: RJ45 port with RS232 protocol, used to connect PC/laptop for local battery data monitoring and firmware upgrades; DCI Port (Dry contact) [2]
Address / DIP setting
DIP Switch: sets protocol address for inverter communication [2]

Not in the manual: Torque, Protection

System limits

Maximum parallel units
16 count [3]
Series connection
no [2]
Maximum system energy
256 kWh [3]
Page 1 of 2 · Installation values · ? means nothing is recordedAggregated, often community-reported information, not official documentation. Do not rely on it for installation, purchase or compliance decisions; always confirm values with the manufacturer’s official documentation. Charged Reviews accepts no responsibility for errors.

Charged Reviews · Quick reference

Pytes V16 16kWh · V16

Warranty

Warranty term10 years[3]
Warranty cycle limit8,000 cycles[3]
Warranted throughput?
Capacity retention?
Cycle rating8,000 cycles[1]
Estimated throughput92 MWh[4] [1]
Coverage starts?
Coverage conditions?
Remedy?
Labor and shipping?
Transfer to another owner?
Registration?

Certifications and listings

UL 1973?
UL 9540?
UL 9540A?
UN 38.3?
IEC 62619?
CE?
UL 9540BClaimed present at observation [3]
CECVerified listed as of snapshot [5]

Documents and sources

  1. Pytes V16 battery datasheet Datasheet · Checked Sep 15, 2026 https://www.pytesusa.com/public/upload/20260519/5d87203a1d9eac449d2386bca1367a4d.pdf
  2. Pytes V16 User Manual EN V20251225 Manufacturer user manual · Revision V20251225 · Checked Sep 25, 2026 https://www.pytesusa.com/public/upload/20260423/d025b5d4d44f0213929027325226b741.pdf
  3. Pytes V16 datasheet (May 2026 upload) Manufacturer datasheet · Checked Sep 21, 2026 https://www.pytesusa.com/public/upload/20260519/5d87203a1d9eac449d2386bca1367a4d.pdf
  4. Pytes V16 Datasheet EN V20260827 Manufacturer datasheet · Revision V20260827 · Checked Sep 25, 2026 https://www.pytesusa.com/public/upload/20260911/04c9579d4f1c06da088e8454136cc26b.pdf
  5. CEC Battery List, official spreadsheet (data unchanged since October 1, 2026; downloaded October 11, 2026) Government equipment list (spreadsheet) · Revision Data unchanged since October 1, 2026 · Revised Oct 1, 2026 · Checked Oct 10, 2026 https://solarequipment.energy.ca.gov/Home/DownloadtoExcel?filename=BatteryList

Unofficial reference. Information may be incorrect. This sheet aggregates the public sources listed above, much of it community-reported. It is not official manufacturer documentation, not an installation guide and not a compliance record. Community-reported values are checked against official manufacturer information before publication; we cannot guarantee accuracy or completeness. Do not rely on this sheet for installation, purchase or compliance decisions: always confirm every value with the manufacturer’s official documentation before buying, wiring or installing equipment. Charged Reviews accepts no responsibility for errors or omissions. Manufacturers can submit documents or corrections.

Page 2 of 2 · Charged Reviews LLC · chargedreviews.com/batteries/pytes-v16Some links pay us a commission. That does not affect what we record.