About brandBattery modules and energy storage systems.
SKU detail
locator: Product page heading "HV48100 SE" and page path /HV-Series/HV48100-SE.html
conditions: Pytes USA publishes this model as "HV48100 SE" with the page path HV48100-SE.html. Pytes lists HV48100 SE, HV48100 and HV48300 Max SE as separate products in the same series navigation.
Cabinet approximate weights for the seven printed configurations: 920 to 1139 kg, endpoints 5S2P and 15S1P. The 45 kg BMU weight is retained in the module-weight row, not cabinet mass. Other configuration weights remain in the configuration rows.
Where: HV48100 SE datasheet p2, General, Approximate weight, seven configuration columns
The 100 Ah row is per BMU and is retained separately. No cabinet Ah row is printed for the seven configurations; no series/parallel capacity is inferred.
Where: HV48100 SE datasheet p2, Battery Module and System tables
Charged Reviews classified this product from the documents it is based on. It is our own grouping, not a manufacturer claim.
Printed as "C&I Energy Storage Solutions OUTDOOR DC ENERGY STORAGE CABINET" and "The maximum configuration per HV48100 SE cabinet is 15S1P / 7S2P.". Classified as Industrial cabinet from the maker's own words for this model (PM decision, October 13, 2026: a commercial or industrial battery cabinet is Industrial cabinet).
Footnote 1 states the number of modules per control unit runs from three to fifteen and that the cabinet has sixteen positions for modules and the control unit, with a maximum configuration of 15S1P or 7S2P.
One HV48100 SE battery module unit (BMU), not the assembled cabinet. One battery module unit, printed as "99 lb / 45 kg". The cabinet's own weight is configuration dependent and runs from 2029 lb / 920 kg (5S2P) to 2511 lb / 1139 kg (15S1P). Pytes's HV48100 datasheet gives the same module as 94.8 lb / 43 kg; that disagreement is recorded in the identity note rather than resolved.
No one nominal system voltage is printed for an unspecified cabinet configuration. The 51.2 V row is per BMU and is retained separately; no series multiplication is used. See the seven printed system operating ranges.
Where: HV48100 SE datasheet p2, Battery Module and System tables
One HV48100 SE battery module unit (BMU), not the assembled cabinet. Rated capacity of one battery module unit. The cabinet holds three to fifteen of them per control unit; a 7S2P cabinet is two strings, so its capacity is twice this figure.
Printed rated energy of the tabulated configurations, 51.20 kWh (5S2P) through 76.80 kWh (15S1P). Each configuration is recorded separately; no module multiplication or usable-energy inference.
Bounds of the seven tabulated cabinet configurations: 5S2P prints 237.5~288 V and 15S1P prints 712.5~864 V. Individual ranges are retained in the configuration rows; this does not assert every intermediate voltage or arbitrary module count is an orderable configuration.
5S2P: rated energy 51.20 kWh; operating voltage 237.5 to 288 V; approximate cabinet weight 920 kg; 6S2P: rated energy 61.44 kWh; operating voltage 285 to 345.6 V; approximate cabinet weight 1013 kg; 7S2P: rated energy 71.68 kWh; operating voltage 332.5 to 403.2 V; approximate cabinet weight 1106 kg; 12S1P: rated energy 61.44 kWh; operating voltage 570 to 691.2 V; approximate cabinet weight 999 kg; 13S1P: rated energy 66.56 kWh; operating voltage 617.5 to 748.8 V; approximate cabinet weight 1046 kg; 14S1P: rated energy 71.68 kWh; operating voltage 665 to 806.4 V; approximate cabinet weight 1092 kg; 15S1P: rated energy 76.80 kWh; operating voltage 712.5 to 864 V; approximate cabinet weight 1139 kg
Transcribed within each printed column, in source order. No module rating is used as a cabinet rating; no arithmetic or continuously selectable range is implied. Footnote 1 discusses 3 to 15 BMUs per BCU; only these seven columns establish the rated energy/weight values here.
Where: HV48100 SE datasheet p2, System and General tables, columns 5S2P / 6S2P / 7S2P / 12S1P / 13S1P / 14S1P / 15S1P
Printed as "-4 °F ~ 131 °F / -20 °C ~ 55 °C" for the cabinet as a whole; the sheet gives no separate charging and discharging ranges. The internal heating film turns on at or below 10 °C and off at or above 15 °C, and the HVAC is rated 2300 W of cooling and 1050 W of heating.
Where: Page 2 specification table, Environmental block, Operating Temperature row
One HV48100 SE battery module unit (BMU), not the assembled cabinet. Nominal voltage of one battery module unit, printed with an operating range of 47.5 V to 57.6 V. The cabinet's own operating voltage depends on the configuration ordered and runs from 237.5-288 V (5S2P) to 712.5-864 V (15S1P).
The largest of the seven tabulated configurations: fifteen modules in series, 76.80 kWh at 38.40 kW and 712.5-864 V. The smallest is 5S2P at 51.20 kWh. A cabinet ordered in any other configuration holds less.
Where: Page 2 specification table, System block, 15S1P column, Rated Energy row
2,644.28 L* (Calculated enclosure volume: W × H × D in mm ÷ 1,000,000)W: 1,100 × H: 2,015 × D: 1,193 mm / W: 43.31 × H: 79.33 × D: 46.97 in
Evidence score
33/100Missing details85% documented
The Evidence score uses the priorities you choose. It counts published documents, such as certificates and warranty terms, and it compares a documented figure with the best documented figure of the same kind. It does not count owner reviews, and it is not a verdict on product quality or on how many people have reviewed it. A low score can mean little is documented, or that a documented figure is below the best of its kind. Undisclosed data scores 0.
Missing details. This number counts only the evidence recorded so far. The source review for this product is not finished, or the maker has not disclosed enough, so the number can only go up.
Missing for this product: Warranty energy disclosure evidence needed; Cell model disclosure evidence needed.
Industrial/Commercial ESS · High voltage · Energy unconfirmed · Rated capacity
The warranty term and the lifetime energy are each scored against the best documented value for a home storage battery: a value earns its share of that best, times the weight. A documented value always earns points; an undisclosed one earns 0.
CertificatesUL 9540 Ed.3 (2023)Claimed15.75 / 45
35 evidence points · 45% weight
UL 9540: strongest qualifying evidence, counted once. Product-scoped manufacturer claim; issuer verification pending. Applies: UL 9540; UL 1973; CEC not assessed for commercial and industrial equipment in this catalog. UL 9540A is recorded but not scored: a thermal-runaway test method, recorded as a documented report and never scored as a listing.
Printed as "System: 3 Years / Battery module: 10 Years"; footnote 3 reads "3 years for the cabinet system (excludes the BMU and BCU), 10 years or 6000 cycles for the battery (whichever comes first)". The 10-year figure recorded here is the battery module term, not the cabinet term. Footnote 4 offers a purchasable 2-year extension.
Research pending, 0 points: Warranty energy disclosure, Cell model disclosure.
Computed from public specifications and evidence records. Warranty duration is not service quality; certificate evidence points are not a safety rating. Compatibility and installation limits still apply.
The HV48100 SE datasheet prints "Certifications UL 9540 Ed.3 (2023), UL 9540A, UL 1973, UN 38.3", "Code Compliance NFPA 68 / 69 / 855" and "Listings CEC, SGIP, OGPe". This is a manufacturer statement on the exact model datasheet: no certificate number, issuing body, certified configuration or validity date was checked.
Printed as "System: 3 Years / Battery module: 10 Years"; footnote 3 reads "3 years for the cabinet system (excludes the BMU and BCU), 10 years or 6000 cycles for the battery (whichever comes first)". The 10-year figure recorded here is the battery module term, not the cabinet term. Footnote 4 offers a purchasable 2-year extension.
Where: Specification table, page 2 of the HV48100 SE datasheet, General, row "Warranty" and footnote 3
Captured by scripts/prepare-brand-sweep-sep21.mjs on 2026-09-22.
Location: Page 2 specification table: Battery Module (BMU), System, General, Battery Module Internal Heating Film, Environmental, Fire Suppression System, HVAC and Compliance blocks with footnotes 1 to 4
Retrieved Sep 21, 2026
The two-page HV48100 SE specification sheet Pytes serves from the Datasheet link of its own HV48100 SE product page, captured byte for byte on September 22, 2026. It establishes the battery module figures (LFP, 5.12 kWh, 51.2 V, 47.5-57.6 V, 100 Ah, 45 kg), the cabinet figures (1100 x 1193 x 2015 mm, IP55, C4-M, 6000 cycles, -20 to 55 °C, 3000 m, 5-80 % humidity), the heating film and HVAC blocks, the four-level fire suppression description and seven tabulated configurations from 5S2P (51.20 kWh) to 15S1P (76.80 kWh), each with its own weight. Because rated energy, power, operating voltage and weight differ by configuration, they are not recorded as single product specifications. It names UL 9540 Ed.3, UL 9540A, UL 1973 and UN 38.3 without a certificate number or issuer record, and NFPA 68/69/855 code compliance and CEC, SGIP and OGPe listings that were not read against any authority register.
Archived copies
Archived copy of a document published by Pytes. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Captured by scripts/prepare-brand-sweep-sep21.mjs on 2026-09-22.
Location: Title block "HV48100 SE"; Datasheet link; product image carousel with alt text "HV48100 SE"
Retrieved Sep 21, 2026
Pytes's own HV48100 SE product page, captured byte for byte on September 22, 2026. It establishes the marketing description, the feature strip, the Datasheet link that serves the May 2026 specification sheet archived alongside it, and the three product photographs the page publishes with alt text "HV48100 SE". The page prints no specification table, no price and no warranty text; every figure recorded for this model comes from the datasheet. It is read here as photograph evidence and as proof that Pytes still lists the model.
Earlier revisions, archived captures and copies published by someone other than the manufacturer. Every one stays reachable.
Archived documents
Pytes HV48100 SE datasheet
Archived copy of a document published by Pytes USA. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
No sourced accessories or replacement parts listed yet.
Model history
Model identity
Model
HV48100 SE
Manufacturer SKU HV48100-SE · US market · Earlier class: DC battery module
Observed Sep 19, 2026
UL 9540 Ed.3 (2023): claimed
Product / system scope unresolved. The HV48100 SE datasheet prints "Certifications UL 9540 Ed.3 (2023), UL 9540A, UL 1973, UN 38.3", "Code Compliance NFPA 68 / 69 / 855" and "Listings CEC, SGIP, OGPe". This is a manufacturer statement on the exact model datasheet: no certificate number, issuing body, certified configuration or validity date was checked.
note: UL 9540: strongest qualifying evidence, counted once. Product-scoped manufacturer claim; issuer verification pending. Applies: UL 9540; UL 1973; CEC not assessed for commercial and industrial equipment in this catalog. UL 9540A is recorded but not scored: a thermal-runaway test method, recorded as a documented report and never scored as a listing.