text: Current manufacturer support for legacy KiloVault products has not been confirmed. The linked HAB warranty names KiloVault, LLC; altE’s later asset acquisition does not establish that a buyer assumed that warranty. No bankruptcy finding is published here.
Printed as "12 V Lithium Iron Phosphate (LiFeP04) with Bluetooth" in the KiloVault HLX and CHLX Lithium Iron Phosphate Deep Cycle Solar Batteries Installation and User Manual (Revision 2.1.2, 04/2021; Internet Archive copy captured 23 February 2024) (PDF page 4, section 1.1, features).
Printed as "KiloVault HLX and CHLX Lithium Iron Phosphate Deep Cycle Solar Batteries" in KiloVault's HLX and CHLX Installation and User Manual (Revision 2.1.2, 04/2021), cover title. Section 1.1 on PDF page 4 prints "12 V Lithium Iron Phosphate (LiFeP04) with Bluetooth" (the formula is printed with a zero).
Printed as "Terminals Stainless Steel M8 - 1.25 x 16 mm Bolts" in KiloVault's HLX and CHLX Installation and User Manual (Revision 2.1.2, 04/2021), 7.3 Physical, Terminals row.
Printed as "3600 CHLX Battery Weight 84.2 lbs (38.2 kg)" in KiloVault's HLX and CHLX Installation and User Manual (Revision 2.1.2, 04/2021), 7.3 Physical, 3600 CHLX Battery Weight row. The CHLX weight; the HLX weight is printed in a separate row.
Printed as "Estimated number of cycles at 100% DoD until 80% of rated watt hour capacity remains 2000" in KiloVault's HLX and CHLX Installation and User Manual (Revision 2.1.2, 04/2021), 7.1 Electrical, estimated cycles at 100% DoD row. The next row prints 5000 cycles at 80% DoD until 80% of rated watt hour capacity remains.
Where: PDF page 28, 7.1 Electrical, estimated cycles at 100% DoD row
Printed as "CHLX Series lithium batteries include all the advantages of the HLX Series with the added benefit of cold weather operation." and "The heater is powered by charging current, not by the battery." in KiloVault's HLX and CHLX Installation and User Manual (Revision 2.1.2, 04/2021), 1.1.3 CHLX Only. PDF page 5 also prints "the CHLX 3600 heater is 192 W".
Printed as "1800/3600 - Peak Discharge Current (<3 seconds) 500 A" in the KiloVault HLX and CHLX Lithium Iron Phosphate Deep Cycle Solar Batteries Installation and User Manual (Revision 2.1.2, 04/2021; Internet Archive copy captured 23 February 2024) (PDF page 27, section 7.1, electrical specifications). Printed as less than 3 seconds.
Where: PDF page 27, section 7.1, electrical specifications
If they will be in a warmer environment you may want to leave a minimum of one inch spacing between each of the batteries.
Printed as "If they will be in a warmer environment you may want to leave a minimum of one inch spacing between each of the batteries." in KiloVault's HLX and CHLX Installation and User Manual (Revision 2.1.2, 04/2021), 3.2 Location.
W 269 × H 221 × L 520 mm / W 10.6 × H 8.7 × L 20.5 in converted
Printed as "3600 HLX/CHLX Height 8.7 in (221 mm)" and "3600 HLX/CHLX Width 10.6 in (269 mm)" and "3600 HLX/CHLX Length 20.5 in (520 mm)" in KiloVault's HLX and CHLX Installation and User Manual (Revision 2.1.2, 04/2021), 7.3 Physical, 3600 HLX/CHLX Height, Width and Length rows. The millimeter figures are printed beside the inch ones (the Length row is on PDF page 31).
Where: PDF page 30 and 31, 7.3 Physical, 3600 HLX/CHLX Height, Width and Length rows
Printed as "Terminals Stainless Steel M8 - 1.25 x 16 mm Bolts" in the KiloVault HLX and CHLX Lithium Iron Phosphate Deep Cycle Solar Batteries Installation and User Manual (Revision 2.1.2, 04/2021; Internet Archive copy captured 23 February 2024) (PDF page 31, section 7.3, physical specifications).
Where: PDF page 31, section 7.3, physical specifications
Printed as "Exception: CHLX can only be wired up to 4 batteries in parallel OR up to 4 batteries in series, but not both." in KiloVault's HLX and CHLX Installation and User Manual (Revision 2.1.2, 04/2021), 3.4 Configurations. Not both: CHLX batteries cannot be wired in a combination series and parallel configuration. PDF page 28 prints "Maximum Configuration - All CHLX Battery Bank Up to 4 batteries in series OR 4 batteries in parallel but not both."
Printed as "1800/3600 - Maximum Charge Current 150 A" in KiloVault's HLX and CHLX Installation and User Manual (Revision 2.1.2, 04/2021), 7.1 Electrical, 1800/3600 Maximum Charge Current row.
Where: PDF page 27, 7.1 Electrical, 1800/3600 Maximum Charge Current row
Printed as "1800/3600 - Peak Discharge Current (<3 seconds) 500 A" in KiloVault's HLX and CHLX Installation and User Manual (Revision 2.1.2, 04/2021), 7.1 Electrical, 1800/3600 Peak Discharge Current row. The printed duration is under 3 seconds.
Where: PDF page 27, 7.1 Electrical, 1800/3600 Peak Discharge Current row
A minimum of 2/0 or 4/0 AWG copper cable for battery interconnect cables
Printed as "A minimum of 2/0 or 4/0 AWG copper cable is recommended for battery interconnect cables." in KiloVault's HLX and CHLX Installation and User Manual (Revision 2.1.2, 04/2021), 3.3 Cabling.
Printed as "Rated Voltage 12.8 VDC" in KiloVault's HLX and CHLX Installation and User Manual (Revision 2.1.2, 04/2021), 7.1 Electrical, Rated Voltage row. A value for every HLX and CHLX battery.
Where: PDF page 28, 7.1 Electrical, Rated Voltage row
Printed as "CHLX can only be wired up to 4 batteries in parallel OR"; "up to 4 batteries in series, but not both." in the KiloVault HLX and CHLX Lithium Iron Phosphate Deep Cycle Solar Batteries Installation and User Manual (Revision 2.1.2, 04/2021; Internet Archive copy captured 23 February 2024) (PDF page 6, section 3.4, configurations). CHLX batteries cannot be wired in a combination series and parallel configuration.
Printed as "1800/3600 - Standard Charge Current 100 A" in KiloVault's HLX and CHLX Installation and User Manual (Revision 2.1.2, 04/2021), 7.1 Electrical, 1800/3600 Standard Charge Current row.
Where: PDF page 27, 7.1 Electrical, 1800/3600 Standard Charge Current row
Printed as "Exception: CHLX can only be wired up to 4 batteries in parallel OR up to 4 batteries in series, but not both." in KiloVault's HLX and CHLX Installation and User Manual (Revision 2.1.2, 04/2021), 3.4 Configurations. Not both: CHLX batteries cannot be wired in a combination series and parallel configuration. PDF page 28 prints "Maximum Configuration - All CHLX Battery Bank Up to 4 batteries in series OR 4 batteries in parallel but not both."
Printed as "3600 - Battery Capacity 3600 Wh, 300 Ah" in KiloVault's HLX and CHLX Installation and User Manual (Revision 2.1.2, 04/2021), 4.1 Inverter/Charger Settings, 3600 Battery Capacity row. Converted from the printed 3600 Wh.
Printed as "Torque all bolts and battery terminals to 88.51 to 97.36 in lb (10 - 11 Nm)." in KiloVault's HLX and CHLX Installation and User Manual (Revision 2.1.2, 04/2021), 3.3 Cabling. The manual prints the range in in lb first and 10 - 11 Nm beside it.
Printed as "1800/3600 - Maximum Continuous Discharge Current 150 A" in the KiloVault HLX and CHLX Lithium Iron Phosphate Deep Cycle Solar Batteries Installation and User Manual (Revision 2.1.2, 04/2021; Internet Archive copy captured 23 February 2024) (PDF page 27, section 7.1, electrical specifications).
Where: PDF page 27, section 7.1, electrical specifications
Printed as "Charging Temperature Range 32°F to 113°F (0°C to 45°C)" in KiloVault's HLX and CHLX Installation and User Manual (Revision 2.1.2, 04/2021), 7.2 Environmental, Charging Temperature Range row. The Celsius figures are printed beside the Fahrenheit ones.
Where: PDF page 29, 7.2 Environmental, Charging Temperature Range row
Printed as "In all of the batteries the heater starts at an internal temperature of 0°C (32°F)." in KiloVault's HLX and CHLX Installation and User Manual (Revision 2.1.2, 04/2021), 1.1.3 CHLX Only.
Printed as "Maximum charge voltage - 14.2 V." in KiloVault's HLX and CHLX Installation and User Manual (Revision 2.1.2, 04/2021), 3.1 Before You Install Your Batteries, requirements for an acceptable charger. A requirement for the charger used to commission each battery.
Where: PDF page 8, 3.1 Before You Install Your Batteries, requirements for an acceptable charger
HLX and CHLX batteries must be placed flat on their bottoms. Any other orientation will void the warranty.
Printed as "HLX and CHLX batteries must be placed flat on their bottoms. Any other orientation will void the warranty." in KiloVault's HLX and CHLX Installation and User Manual (Revision 2.1.2, 04/2021), 3.2 Location. The same section says not to stack them one directly on top of another.
Printed as "1800/3600 - Recommended Charge Current 100 A per HLX in Parallel" in the KiloVault HLX and CHLX Lithium Iron Phosphate Deep Cycle Solar Batteries Installation and User Manual (Revision 2.1.2, 04/2021; Internet Archive copy captured 23 February 2024) (PDF page 13, section 4.1, inverter/charger settings). Per battery (per string in parallel).
Where: PDF page 13, section 4.1, inverter/charger settings
Printed as "Recommended Storage Temperature and Humidity: 15°C to 35°C, 45% to 75% Relative Humidity." in KiloVault's HLX and CHLX Installation and User Manual (Revision 2.1.2, 04/2021), 6 Storage and Recommissioning. The same paragraph allows -20°C to 45°C for 1 month or less and -10°C to 35°C for 3 months or less.
Printed as "1800/3600 - Maximum Continuous Discharge Current 150 A" in KiloVault's HLX and CHLX Installation and User Manual (Revision 2.1.2, 04/2021), 7.1 Electrical, 1800/3600 Maximum Continuous Discharge Current row.
Where: PDF page 27, 7.1 Electrical, 1800/3600 Maximum Continuous Discharge Current row
Printed as "High Voltage Shutoff Protection 14.4 ±0.2 V" in KiloVault's HLX and CHLX Installation and User Manual (Revision 2.1.2, 04/2021), 7.1 Electrical, High Voltage Shutoff Protection row. The printed tolerance is ±0.2 V.
Where: PDF page 28, 7.1 Electrical, High Voltage Shutoff Protection row
Printed as "Discharging Temperature Range -4°F to 140°F (-20°C to 60°C)" in KiloVault's HLX and CHLX Installation and User Manual (Revision 2.1.2, 04/2021), 7.2 Environmental, Discharging Temperature Range row. The Celsius figures are printed beside the Fahrenheit ones.
Where: PDF page 29, 7.2 Environmental, Discharging Temperature Range row
Printed as "HLX iT Bluetooth Monitoring Application (iOS and Android)" in the KiloVault HLX and CHLX Lithium Iron Phosphate Deep Cycle Solar Batteries Installation and User Manual (Revision 2.1.2, 04/2021; Internet Archive copy captured 23 February 2024) (PDF page 4, section 1.1, features).
Printed as "Low Voltage Shutoff Protection 11.5 V" in KiloVault's HLX and CHLX Installation and User Manual (Revision 2.1.2, 04/2021), 7.1 Electrical, Low Voltage Shutoff Protection row.
Where: PDF page 28, 7.1 Electrical, Low Voltage Shutoff Protection row
Printed as "Bulk Voltage 14.1 V" and "Absorb Voltage 14.1 V" in KiloVault's HLX and CHLX Installation and User Manual (Revision 2.1.2, 04/2021), 4.1 Inverter/Charger Settings, Bulk Voltage row. Absorb Voltage 14.1 V is printed on PDF page 12; volts are per battery in a single string.
Where: PDF page 13, 4.1 Inverter/Charger Settings, Bulk Voltage row
30.91 L* (Calculated enclosure volume: W × H × D in mm ÷ 1,000,000)W: 269 × H: 221 × L: 520 mm / W: 10.6 × H: 8.7 × L: 20.5 in38.2 kg / 84.2 lb0.12 kWh/L* (Rated or usable capacity shown on this card ÷ enclosure volume)
Evidence score
12/100Missing details40% documented
The Evidence score uses the priorities you choose. It counts published documents, such as certificates and warranty terms, and it compares a documented figure with the best documented figure of the same kind. It does not count owner reviews, and it is not a verdict on product quality or on how many people have reviewed it. A low score can mean little is documented, or that a documented figure is below the best of its kind. Undisclosed data scores 0.
Missing details. This number counts only the evidence recorded so far. The source review for this product is not finished, or the maker has not disclosed enough, so the number can only go up.
Missing for this product: Certificates evidence needed; Warranty energy disclosure evidence needed; Cell model disclosure evidence needed.
12 V · Format not recorded · Rated capacity
The warranty term and the lifetime energy are each scored against the best documented value for a home storage battery: a value earns its share of that best, times the weight. A documented value always earns points; an undisclosed one earns 0.
Printed as "Prorated Credit Period (months) Total Warranty Period (years)"; "HLX/CHLX 3600 36 54 7.5" in the KiloVault HLX and CHLX Lithium Iron Phosphate Deep Cycle Solar Batteries Installation and User Manual (Revision 2.1.2, 04/2021; Internet Archive copy captured 23 February 2024) (PDF page 32, section 10, limited warranty table).
Research pending, 0 points: Certificates, Warranty energy disclosure, Cell model disclosure.
Computed from public specifications and evidence records. Warranty duration is not service quality; certificate evidence points are not a safety rating. Compatibility and installation limits still apply.
What this shows: what each record says and how far it reaches. It does not mean the product is approved.
Unknown: no certification evidence recorded in this data.
Warranty
Field
Value
Conditions
Source
Remedy
Free replacement or repair for 36 months, then a prorated credit for 54 months
Printed as "Model Free Replacement or Repair Period (months) Prorated Credit Period (months)"; "HLX/CHLX 3600 36 54 7.5" in the KiloVault HLX and CHLX Lithium Iron Phosphate Deep Cycle Solar Batteries Installation and User Manual (Revision 2.1.2, 04/2021; Internet Archive copy captured 23 February 2024) (PDF page 32, section 10, limited warranty table).
Where: PDF page 32, section 10, limited warranty table
Original purchaser only; not transferable to any other person or entity
Printed as "This Limited Warranty is to the original purchaser of the Product and is not transferable" in the KiloVault HLX and CHLX Lithium Iron Phosphate Deep Cycle Solar Batteries Installation and User Manual (Revision 2.1.2, 04/2021; Internet Archive copy captured 23 February 2024) (PDF page 32, section 10, non-transferable).
No obligation for: damage during shipping or mishandling; improper installation (loose terminal connections, under-sized cabling, unequal interconnect cables, incorrect series or parallel connections, reverse polarity, insufficient airflow space); environmental damage (inappropriate storage, extreme heat or cold, fire, freezing, water); damage in operation from collision, over-charging or over-discharging; lightning, fire, water or acts of God; improper maintenance; product that has been opened, modified or tampered with. Claims go to the place of purchase.
Printed as "Damage caused during shipping or mishandling of the Product"; "Damage due to improper installation; loose terminal connections, under-sized cabling"; "Product that has been opened, modified or tampered with"; "Please contact the place of purchase regarding any warranty claim." in the KiloVault HLX and CHLX Lithium Iron Phosphate Deep Cycle Solar Batteries Installation and User Manual (Revision 2.1.2, 04/2021; Internet Archive copy captured 23 February 2024) (PDF page 32, section 10, warranty exclusions and limitations).
Where: PDF page 32, section 10, warranty exclusions and limitations
Printed as "Prorated Credit Period (months) Total Warranty Period (years)"; "HLX/CHLX 3600 36 54 7.5" in the KiloVault HLX and CHLX Lithium Iron Phosphate Deep Cycle Solar Batteries Installation and User Manual (Revision 2.1.2, 04/2021; Internet Archive copy captured 23 February 2024) (PDF page 32, section 10, limited warranty table).
Where: PDF page 32, section 10, limited warranty table
Internet Archive copy of KiloVault's file (capture of 23 February 2024), obtained by Alternative Research on 2 October 2026.
Location: PDF page 1 (cover and revision) and PDF page 4 (1.1 Features, models covered)
Retrieved Oct 1, 2026
KiloVault's own installation and user manual for its HLX and CHLX batteries, originally at https://www.kilovault.com/wp-content/uploads/2021/04/KiloVault_HLX_Series_Manual_V2.1.2_April022021.pdf; the cover prints "Revision: 2.1.2, 04/2021". Section 1.1 lists the models KLV1200HLX and CHLX, KLV1800HLX and CHLX and KLV3800HLX and CHLX (the last with 300 Ah/3600 Wh), and its specification tables give the 1800 and 3600 figures, with separate CHLX rows for weight and heater power. KiloVault's CHLX Series page, as the Internet Archive captured it on 23 February 2024, links this file as the KiloVault CHLX Installation and User Manual. KiloVault's own site could not be read with our research agent (its robots.txt answered HTTP 522), so this copy was obtained by Alternative Research on 2 October 2026 from the Internet Archive, which captured KiloVault's own file on 23 February 2024. It is labeled as an archived copy, not a current download from KiloVault. Manufacturer instructions, not independent tests.
Archived copy of a document published by KiloVault. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Earlier revisions, archived captures and copies published by someone other than the manufacturer. Every one stays reachable.
Archived documents
KiloVault datasheet
Archived copy of a document published by KiloVault. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
No sourced accessories or replacement parts listed yet.
Model history
Model identity
Model
CHLX 3600
No historical observations recorded yet.
Other recorded fields
Field
Value
Conditions
Source
Evidence breakdown
method version: 0.21-personal
documented pct: 40
basis: nominal
missing:
Certificates evidence needed
Warranty energy disclosure evidence needed
Cell model disclosure evidence needed
criteria:
key: certificateEvidence
label: Certificates
value: 0
unit: evidence points
shown: Research pending
shown detail: Unknown
state: pending
points: 0
ceiling: 45
weight: 45
share: 0
covered: no
missing: yes
folded: yes
reason: Unknown
reason text: Unknown
note: No qualifying applicable evidence recorded. This is not proof that certification is absent. Applies: UL 1973; CEC not applicable to 12 V / 24 V / 36 V DC modules; UL 9540 not applicable to 12 V / 24 V / 36 V DC modules.