text: Current manufacturer support for legacy KiloVault products has not been confirmed. The linked HAB warranty names KiloVault, LLC; altE’s later asset acquisition does not establish that a buyer assumed that warranty. No bankruptcy finding is published here.
Printed as "12 V Lithium Iron Phosphate (LiFeP04), a.k.a. LFP, with Bluetooth" in the KiloVault user manual (page 5, 1.1 Features). Monitored with the HLX iT app; applies to all models.
Printed as "Terminals Stainless Steel M8 - 1.25 x 16 mm Bolts" in the KiloVault user manual (page 27, 7.3 Physical, Terminals row). In all models the terminals extend 1 mm above the case.
Printed as "Rated Capacity 100 Ah Recommended Charge Current ≤50 A" in the KiloVault user manual (page 25, 7.1.2 1200 HLX+, Rated Capacity row). 1200 HLX+ table; 1.1 Features also prints 100 Ah.
Where: PDF page 25, 7.1.2 1200 HLX+, Rated Capacity row
Printed as "Internal heater allows the battery to continue charging" in the KiloVault user manual (page 5, 1.1 Features and 1.1.4 Heating System). The heater is powered by charging current, not by the battery. Applies to all models.
Where: PDF page 5, 1.1 Features and 1.1.4 Heating System
Printed as "Terminals Stainless Steel M8 - 1.25 x 16 mm Bolts" in the KiloVault user manual (page 27, 7.3 Physical, Terminals row). Applies to all models.
Printed as "Up to 4 parallel strings of 4 batteries in series. Total of 16." in the KiloVault user manual (page 23, 7.1.1 All Models, Maximum Configuration rows). Without the HLX+ Bridge and below freezing, the limit is 4 in series or 4 in parallel, not both.
Where: PDF page 23, 7.1.1 All Models, Maximum Configuration rows
Printed as "Maximum Continuous Charge Current 80 A Maximum Continuous Discharge Current 80 A" in the KiloVault user manual (page 24, 7.1.2 1200 HLX+, Maximum Continuous Charge Current row). 1200 HLX+ table.
Where: PDF page 24, 7.1.2 1200 HLX+, Maximum Continuous Charge Current row
Printed as "Peak or Surge Discharge Current 350 A for less than 3 seconds" in the KiloVault user manual (page 25, 7.1.2 1200 HLX+, Peak or Surge Discharge Current row). For less than 3 seconds.
Where: PDF page 25, 7.1.2 1200 HLX+, Peak or Surge Discharge Current row
Printed as "where one, two, three or four batteries are connected in series" in the KiloVault user manual (page 9, 3.4 Configurations). Applies to all models.
Printed as "Up to 4 parallel strings of 4 batteries in series. Total of 16." in the KiloVault user manual (page 23, 7.1.1 All Models, Maximum Configuration rows). Counted as parallel strings of up to 4 batteries each. Without the HLX+ Bridge and below freezing, the limit is 4 in series or 4 in parallel, not both.
Where: PDF page 23, 7.1.1 All Models, Maximum Configuration rows
Printed as "Tighten the terminal bolts to between 7.38 and 8.11 ft-lbs"; "(88.51 to 97.36 in-lbs OR 10 to 11 nm)" in the KiloVault user manual (pages 9, 27, 7.3 Physical, Terminal torque row). Applies to all models.
Where: PDF pages 9, 27, 7.3 Physical, Terminal torque row
Printed as "Maximum Continuous Charge Current 80 A Maximum Continuous Discharge Current 80 A" in the KiloVault user manual (page 24, 7.1.2 1200 HLX+, Maximum Continuous Discharge Current row). 1200 HLX+ table.
Where: PDF page 24, 7.1.2 1200 HLX+, Maximum Continuous Discharge Current row
Printed as "Internal Temperature Range - Charging 32°F to 113°F (0°C to 45°C)" in the KiloVault user manual (page 26, 7.2 Environmental, Internal Temperature Range - Charging row). Internal battery temperature; applies to all models.
Where: PDF page 26, 7.2 Environmental, Internal Temperature Range - Charging row
Printed as "the heater starts at an internal temperature of 0°C (32°F)" in the KiloVault user manual (page 6, 1.1.4 Heating System). Stops at an internal temperature of 5°C (41°F). Applies to all models.
Printed as "ii. Maximum charge voltage - 14.1 V." in the KiloVault user manual (page 8, 3.1 Before You Install Your Batteries, acceptable charger list). Printed as a requirement for an acceptable 12 V charger; applies to all models.
Where: PDF page 8, 3.1 Before You Install Your Batteries, acceptable charger list
Printed as "Rated Capacity 100 Ah Recommended Charge Current ≤50 A" in the KiloVault user manual (page 25, 7.1.2 1200 HLX+, Recommended Charge Current row). Printed as an upper limit (≤50 A).
Where: PDF page 25, 7.1.2 1200 HLX+, Recommended Charge Current row
Printed as "Recommended Storage Temperature and Humidity: 15°C to 35°C" in the KiloVault user manual (page 22, 6 Storage and Recommissioning). Recommended storage range; the manual separately allows -20°C to 45°C for 1 month or less and -10°C to 35°C for 3 months or less. Applies to all models.
Where: PDF page 22, 6 Storage and Recommissioning
Sources
-20 to 45 °C
Printed as "(-20°C to 45°C), 45% to 75% Relative Humidity for 1 month or less".
Printed as "High Voltage Shutoff Protection ≈14.4 ±0.2 V" in the KiloVault user manual (page 23, 7.1.1 All Models, High Voltage Shutoff Protection row). Printed as approximate (≈14.4 ±0.2 V); applies to all models.
Where: PDF page 23, 7.1.1 All Models, High Voltage Shutoff Protection row
Printed as "Internal Temperature Range - Discharging -4°F to 131°F (-20°C to 55°C)" in the KiloVault user manual (page 26, 7.2 Environmental, Internal Temperature Range - Discharging row). Internal battery temperature; applies to all models.
Where: PDF page 26, 7.2 Environmental, Internal Temperature Range - Discharging row
Printed as "Ambient Temperature Range -4°F to 113°F (-20° C to 45°C)" in the KiloVault user manual (page 26, 7.2 Environmental, Ambient Temperature Range row). Ambient range; applies to all models.
Where: PDF page 26, 7.2 Environmental, Ambient Temperature Range row
Printed as "Low Voltage Shutoff Protection ≈10.2 ±0.2 V" in the KiloVault user manual (page 23, 7.1.1 All Models, Low Voltage Shutoff Protection row). Printed as approximate (≈10.2 ±0.2 V); applies to all models.
Where: PDF page 23, 7.1.1 All Models, Low Voltage Shutoff Protection row
Printed as "Recommended Charge Voltage 14.1 V" in the KiloVault user manual (page 23, 7.1.1 All Models, Recommended Charge Voltage row). Applies to all models.
Where: PDF page 23, 7.1.1 All Models, Recommended Charge Voltage row
12.33 L* (Calculated enclosure volume: W × H × D in mm ÷ 1,000,000)W: 165 × H: 235 × L: 318 mm / W: 6.5 × H: 9.25 × L: 12.5 in11.7 kg / 25.8 lb0.1 kWh/L* (Rated or usable capacity shown on this card ÷ enclosure volume)
Evidence score
8/100Missing details20% documented
The Evidence score uses the priorities you choose. It counts published documents, such as certificates and warranty terms, and it compares a documented figure with the best documented figure of the same kind. It does not count owner reviews, and it is not a verdict on product quality or on how many people have reviewed it. A low score can mean little is documented, or that a documented figure is below the best of its kind. Undisclosed data scores 0.
Missing details. This number counts only the evidence recorded so far. The source review for this product is not finished, or the maker has not disclosed enough, so the number can only go up.
Missing for this product: Certificates evidence needed; Warranty energy disclosure evidence needed; Lifetime / capacity evidence needed; Cell model disclosure evidence needed.
12 V · Format not recorded · Rated capacity
The warranty term and the lifetime energy are each scored against the best documented value for a home storage battery: a value earns its share of that best, times the weight. A documented value always earns points; an undisclosed one earns 0.
Printed as "HLX+ 1200 36 54 7.5" in the KiloVault user manual (page 30, 10 Limited Warranty table). Total Warranty Period (years) column, HLX+ 1200 row.
Research pending, 0 points: Certificates, Warranty energy disclosure, Cell model disclosure.
Computed from public specifications and evidence records. Warranty duration is not service quality; certificate evidence points are not a safety rating. Compatibility and installation limits still apply.
What this shows: what each record says and how far it reaches. It does not mean the product is approved.
Unknown: no certification evidence recorded in this data.
Warranty
Field
Value
Conditions
Source
Remedy
Free replacement or repair for 36 months, then prorated credit for 54 months
Printed as "Model Free Replacement or Repair Period (months) Prorated Credit Period (months)"; "HLX+ 1200 36 54 7.5" in the KiloVault user manual (page 30, 10 Limited Warranty table). The HLX+ 1200 row of the warranty table.
The manual asks owners to register HLX+ batteries at https://kilovault.com/register/
Printed as "Please register your HLX+ batteries at - https://kilovault.com/register/" in the KiloVault user manual (page 30, 10.1 Registration). Applies to all models.
Printed as "HLX+ 1200 36 54 7.5" in the KiloVault user manual (page 30, 10 Limited Warranty table). Total Warranty Period (years) column, HLX+ 1200 row.
Archived copy of a document published by KiloVault. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Earlier revisions, archived captures and copies published by someone other than the manufacturer. Every one stays reachable.
Archived documents
KiloVault user manual
Archived copy of a document published by KiloVault. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
No sourced accessories or replacement parts listed yet.
Model history
Model identity
Model
1200 HLX+
No historical observations recorded yet.
Other recorded fields
Field
Value
Conditions
Source
Evidence breakdown
method version: 0.21-personal
documented pct: 20
basis: nominal
missing:
Certificates evidence needed
Warranty energy disclosure evidence needed
Lifetime / capacity evidence needed
Cell model disclosure evidence needed
criteria:
key: certificateEvidence
label: Certificates
value: 0
unit: evidence points
shown: Research pending
shown detail: Unknown
state: pending
points: 0
ceiling: 45
weight: 45
share: 0
covered: no
missing: yes
folded: yes
reason: Unknown
reason text: Unknown
note: No qualifying applicable evidence recorded. This is not proof that certification is absent. Applies: UL 1973; CEC not applicable to 12 V / 24 V / 36 V DC modules; UL 9540 not applicable to 12 V / 24 V / 36 V DC modules.