Printed as "Cell Type LFP (LiFePO4)" in GoodWe's Commercial Smart Inverter Solutions User Manual for ET 15-30kW systems (V2.2, 2026-05-25), 9.2.3 BAT-C Series 61.4-112.6kWh C&I Battery System, Technical Data, Battery System, Cell Type row, one entry for every model.
Where: PDF page 304, 9.2.3 BAT-C Series 61.4-112.6kWh C&I Battery System, Technical Data, Cell Type row, GW112.6-BAT-AC-G10 column
Printed as "Conductor cross-sectional area: 16-25mm²" in GoodWe's Commercial Smart Inverter Solutions User Manual for ET 15-30kW systems (V2.2, 2026-05-25), 5.3.2 Preparing Cables, Battery Protective Grounding Cable row for the BAT-C Series 61.4-112.6kWh system, which specifies a single-core outdoor copper cable, customer-supplied. The grounding figure on PDF page 134 prints the same "Cu, 16-25mm²"..
Where: PDF page 128, 5.3.2 Preparing Cables, Battery Protective Grounding Cable row for the BAT-C Series
Printed as "Weight (kg) <950 <1220 <1310 <1400" in GoodWe's Commercial Smart Inverter Solutions User Manual for ET 15-30kW systems (V2.2, 2026-05-25), 9.2.3 BAT-C Series 61.4-112.6kWh C&I Battery System, Technical Data, Weight (kg) row; the GW112.6-BAT-AC-G10 column prints <1400, an upper bound (less than 1400 kg). Re-cited on 1 October 2026 to the manufacturer's own document; previously cited to GoodWe (en.goodwe.com), which stays listed as an additional source.
Where: PDF page 307, 9.2.3 BAT-C Series 61.4-112.6kWh C&I Battery System, Technical Data, Weight (kg) row, GW112.6-BAT-AC-G10 column
Printed as "≥6000 times until 70% SOH under 25±2°C.0.5C and 100% DOD" in GoodWe's Commercial Smart Inverter Solutions User Manual for ET 15-30kW systems (V2.2, 2026-05-25), 9.2.3 BAT-C Series 61.4-112.6kWh C&I Battery System, Technical Data, Cycle Life row, one entry for every model; the figure is printed as a lower bound (at least 6000 cycles). Re-cited on 1 October 2026 to the manufacturer's own document; previously cited to GoodWe (en.goodwe.com), which stays listed as an additional source.
Where: PDF page 306, 9.2.3 BAT-C Series 61.4-112.6kWh C&I Battery System, Technical Data, Cycle Life row, GW112.6-BAT-AC-G10 column
Printed as "Rated Capacity (Ah) 200" in GoodWe's Commercial Smart Inverter Solutions User Manual for ET 15-30kW systems (V2.2, 2026-05-25), 9.2.3 BAT-C Series 61.4-112.6kWh C&I Battery System, Technical Data, Rated Capacity (Ah) row, one figure for every model (cell capacity is printed separately as 100 Ah). Re-cited on 1 October 2026 to the manufacturer's own document; previously cited to GoodWe (en.goodwe.com), which stays listed as an additional source.
Where: PDF page 305, 9.2.3 BAT-C Series 61.4-112.6kWh C&I Battery System, Technical Data, Rated Capacity (Ah) row, GW112.6-BAT-AC-G10 column
Read from rendered page 90: GoodWe's Commercial Smart Inverter Solutions User Manual for ET 15-30kW systems (V2.2, 2026-05-25), 4.2.3 Installation Space Requirements, figure part labeled "BAT 61.4-112.6kWh C&I", which prints "≥300mm" above the cabinet, "≥800mm" to the left beyond the inverter mounted on the cabinet's side, "50mm" on the right, and "≥1200mm" at the front and at the back. The section notes the values can be adjusted to the actual installation scenario and local regulations.
Where: PDF page 90, 4.2.3 Installation Space Requirements, BAT 61.4-112.6kWh C&I figure
W 1,055 × H 2,000 × D 1,055 mm / W 41.54 × H 78.74 × D 41.54 in converted
Printed as "Dimension (W×H×Dmm) 1055*2000*1055" in GoodWe's Commercial Smart Inverter Solutions User Manual for ET 15-30kW systems (V2.2, 2026-05-25), 9.2.3 BAT-C Series 61.4-112.6kWh C&I Battery System, Technical Data, one entry for every model. Re-cited on 1 October 2026 to the manufacturer's own document; previously cited to GoodWe (en.goodwe.com), which stays listed as an additional source.
Where: PDF page 307, 9.2.3 BAT-C Series 61.4-112.6kWh C&I Battery System, Technical Data, Dimension (W×H×Dmm) row, GW112.6-BAT-AC-G10 column
Charged Reviews classified this product from the documents it is based on. It is our own grouping, not a manufacturer claim.
Printed as "Highly integrated cabinet for easy transportation and installation" in the GoodWe BAT-C Series datasheet (GoodWe-Single page -20260313-EN-V2.1), captured September 27, 2026.
Printed as "Communication CAN (RS485 Optional)" in GoodWe's Commercial Smart Inverter Solutions User Manual for ET 15-30kW systems (V2.2, 2026-05-25), 9.2.3 BAT-C Series 61.4-112.6kWh C&I Battery System, Technical Data, one entry for every model.
Where: PDF page 307, 9.2.3 BAT-C Series 61.4-112.6kWh C&I Battery System, Technical Data, Communication row, GW112.6-BAT-AC-G10 column
Printed as "Ingress Protection Rating IP55 IP55 IP55 IP55" in GoodWe's Commercial Smart Inverter Solutions User Manual for ET 15-30kW systems (V2.2, 2026-05-25), 9.2.3 BAT-C Series 61.4-112.6kWh C&I Battery System, Technical Data, one rating per model column. Re-cited on 1 October 2026 to the manufacturer's own document; previously cited to GoodWe (en.goodwe.com), which stays listed as an additional source.
Where: PDF page 307, 9.2.3 BAT-C Series 61.4-112.6kWh C&I Battery System, Technical Data, Ingress Protection Rating row, GW112.6-BAT-AC-G10 column
Printed as "Nominal Voltage (V) 307.2 460.8 512 563.2" in GoodWe's Commercial Smart Inverter Solutions User Manual for ET 15-30kW systems (V2.2, 2026-05-25), 9.2.3 BAT-C Series 61.4-112.6kWh C&I Battery System, Technical Data, Nominal Voltage (V) row; the GW112.6-BAT-AC-G10 column prints 563.2. Re-cited on 1 October 2026 to the manufacturer's own document; previously cited to GoodWe (en.goodwe.com), which stays listed as an additional source.
Where: PDF page 305, 9.2.3 BAT-C Series 61.4-112.6kWh C&I Battery System, Technical Data, Nominal Voltage (V) row, GW112.6-BAT-AC-G10 column
Printed as "Usable Energy (kWh) *1 60 90 100 110" in GoodWe's Commercial Smart Inverter Solutions User Manual for ET 15-30kW systems (V2.2, 2026-05-25), 9.2.3 BAT-C Series 61.4-112.6kWh C&I Battery System, Technical Data, Usable Energy (kWh) row; the GW112.6-BAT-AC-G10 column prints 110. The table's notes give the test conditions as 100% DOD, 0.2C charge and discharge at +25±2 °C at beginning of life, and say system usable energy may vary with system configuration. Re-cited on 1 October 2026 to the manufacturer's own document; previously cited to GoodWe (en.goodwe.com), which stays listed as an additional source.
Where: PDF page 305, 9.2.3 BAT-C Series 61.4-112.6kWh C&I Battery System, Technical Data, Usable Energy (kWh) row, GW112.6-BAT-AC-G10 column
2P DC Switch, Rated Current ≥63A, Nominal Voltage ≥1000V
Printed as "2P DC Switch" in GoodWe's Commercial Smart Inverter Solutions User Manual for ET 15-30kW systems (V2.2, 2026-05-25), 5.3.1 Preparing Breakers, No. 4 Battery Switch row, which reads in full "Select according to local laws and regulations", then "2P DC Switch", "Rated Current ≥63A" and "Nominal Voltage ≥1000V", marked self-provided. The row is written for the battery switch of the whole system, whichever of the manual's batteries is used..
Printed as "Pack Configuration 2P96S 2P144S 2P160S 2P176S" in GoodWe's Commercial Smart Inverter Solutions User Manual for ET 15-30kW systems (V2.2, 2026-05-25), 9.2.3 BAT-C Series 61.4-112.6kWh C&I Battery System, Technical Data, Pack Configuration row; the GW112.6-BAT-AC-G10 column prints 2P176S, a figure that grows with the model's number of packs.
Where: PDF page 305, 9.2.3 BAT-C Series 61.4-112.6kWh C&I Battery System, Technical Data, Pack Configuration row, GW112.6-BAT-AC-G10 column
Printed as "≥6000 times until 70% SOH under 25±2°C.0.5C and 100% DOD" in the same maker document as the recorded cycle life; the cycle life ends at 70% of capacity as printed.
Where: PDF page 306, 9.2.3 BAT-C Series 61.4-112.6kWh C&I Battery System, Technical Data, Cycle Life row, GW112.6-BAT-AC-G10 column
Battery cabinet x1, expansion screw x4, grounding M5 screw x3, grounding terminal x3, inverter battery connection terminal 25mm² x2, inter-battery connection terminal 50mm² x2, pack series wiring harness x10, pack negative to high-voltage box negative wiring harness x1, inverter battery connection (positive) x1, inverter battery connection (negative) x1, adapter bracket x2 (required for ET100 only), battery to inverter communication network cable x1, air conditioner power supply wiring harness kit x1, lifting ring x4, cable tie x20, air conditioner water pipe kit x1, fireproofing mud x8, corrugated pipe connector x6, 25mm² to 10mm² round tube terminal x4, product documentation x1
Listed in section 3.2.2.3 (BAT Series 61.4-112.6kWh Industrial & Commercial Battery System deliverables) of the GoodWe Commercial Smart Inverter Solutions user manual for ET 15-30kW systems (V2.2, 2026-05-25) (PDF pages 77-78); the pack series wiring harness count is printed per model as "GW112.6-BAT-AC-G10:×10".
Where: PDF pages 77-78, 3.2.2.3 BAT Series 61.4-112.6kWh deliverables
Printed as "Only supports a single cluster." in GoodWe's Commercial Smart Inverter Solutions User Manual for ET 15-30kW systems (V2.2, 2026-05-25), 2.2 Product Overview, description listing GW61.4-BAT-AC-G10, GW92.1-BAT-AC-G10, GW102.4-BAT-AC-G10 and GW112.6-BAT-AC-G10; one cluster, no parallel clusters, in a system built on the ET 15-30kW inverters this manual covers.
Where: PDF page 29, 2.2 Product Overview, battery system description for the GW61.4-BAT-AC-G10 to GW112.6-BAT-AC-G10 models
Printed as "Nominal Energy (kWh) 61.4 92.1 102.4 112.6" in GoodWe's Commercial Smart Inverter Solutions User Manual for ET 15-30kW systems (V2.2, 2026-05-25), 9.2.3 BAT-C Series 61.4-112.6kWh C&I Battery System, Technical Data, Nominal Energy (kWh) row; the GW112.6-BAT-AC-G10 column prints 112.6. Re-cited on 1 October 2026 to the manufacturer's own document; previously cited to GoodWe (en.goodwe.com), which stays listed as an additional source.
Where: PDF page 305, 9.2.3 BAT-C Series 61.4-112.6kWh C&I Battery System, Technical Data, Nominal Energy (kWh) row, GW112.6-BAT-AC-G10 column
Printed as "Discharge Current (A) *2 180/220" in GoodWe's Commercial Smart Inverter Solutions User Manual for ET 15-30kW systems (V2.2, 2026-05-25), 9.2.3 BAT-C Series 61.4-112.6kWh C&I Battery System, Technical Data, Max. Charge/Discharge Current (A) row, one figure pair for every model; 180 A is the charge figure. Footnote 1 says actual charge and discharge current derates with cell temperature and state of charge; the table also prints a Rated Charge/Discharge Current of 100/100 A, which footnote 1 marks as for Australia only. The manual labels the recorded figure as a maximum, as the datasheet does. Re-cited on 1 October 2026 to the manufacturer's own document; previously cited to GoodWe (en.goodwe.com), which stays listed as an additional source.
Where: PDF page 306, 9.2.3 BAT-C Series 61.4-112.6kWh C&I Battery System, Technical Data, Max. Charge/Discharge Current (A) row, GW112.6-BAT-AC-G10 column
Printed as "Charging Operating Temperature Range(℃) -20~+55" in GoodWe's Commercial Smart Inverter Solutions User Manual for ET 15-30kW systems (V2.2, 2026-05-25), 9.2.3 BAT-C Series 61.4-112.6kWh C&I Battery System, Technical Data, one range for every model. Re-cited on 1 October 2026 to the manufacturer's own document; previously cited to GoodWe (en.goodwe.com), which stays listed as an additional source.
Where: PDF page 305, 9.2.3 BAT-C Series 61.4-112.6kWh C&I Battery System, Technical Data, Charging Operating Temperature Range row, GW112.6-BAT-AC-G10 column
Printed as "Discharge Current (A) *2 180/220" in GoodWe's Commercial Smart Inverter Solutions User Manual for ET 15-30kW systems (V2.2, 2026-05-25), 9.2.3 BAT-C Series 61.4-112.6kWh C&I Battery System, Technical Data, Max. Charge/Discharge Current (A) row, one figure pair for every model; 220 A is the discharge figure. Footnote 1 says actual charge and discharge current derates with cell temperature and state of charge; the table also prints a Rated Charge/Discharge Current of 100/100 A, which footnote 1 marks as for Australia only. The manual labels the recorded figure as a maximum, as the datasheet does. Re-cited on 1 October 2026 to the manufacturer's own document; previously cited to GoodWe (en.goodwe.com), which stays listed as an additional source.
Where: PDF page 306, 9.2.3 BAT-C Series 61.4-112.6kWh C&I Battery System, Technical Data, Max. Charge/Discharge Current (A) row, GW112.6-BAT-AC-G10 column
Read from rendered page 134: GoodWe's Commercial Smart Inverter Solutions User Manual for ET 15-30kW systems (V2.2, 2026-05-25), 5.4.2 Battery System Grounding, BAT-C series 61.4-112.6kWh figure, step 3, which prints "M5" and "4N·m" for the ground screw.
Where: PDF page 134, 5.4.2 Battery System Grounding, BAT-C series figure, step 3
Printed as "Discharging Operating Temperature Range(℃) -20~+55" in GoodWe's Commercial Smart Inverter Solutions User Manual for ET 15-30kW systems (V2.2, 2026-05-25), 9.2.3 BAT-C Series 61.4-112.6kWh C&I Battery System, Technical Data, one range for every model. Re-cited on 1 October 2026 to the manufacturer's own document; previously cited to GoodWe (en.goodwe.com), which stays listed as an additional source.
Where: PDF page 305, 9.2.3 BAT-C Series 61.4-112.6kWh C&I Battery System, Technical Data, Discharging Operating Temperature Range row, GW112.6-BAT-AC-G10 column
Printed as "General Data Operating Temperature Range (℃) -20~+55" in GoodWe's Commercial Smart Inverter Solutions User Manual for ET 15-30kW systems (V2.2, 2026-05-25), 9.2.3 BAT-C Series 61.4-112.6kWh C&I Battery System, Technical Data, one range for every model.
Where: PDF page 306, 9.2.3 BAT-C Series 61.4-112.6kWh C&I Battery System, Technical Data, Operating Temperature Range (General Data) row, GW112.6-BAT-AC-G10 column
2,226.05 L* (Calculated enclosure volume: W × H × D in mm ÷ 1,000,000)W: 1,055 × H: 2,000 × D: 1,055 mm / W: 41.54 × H: 78.74 × D: 41.54 in1,400 kg / 3,086 lb0.05 kWh/L* (Rated or usable capacity shown on this card ÷ enclosure volume)
Evidence score
11/100Missing details40% documented
The Evidence score uses the priorities you choose. It counts published documents, such as certificates and warranty terms, and it compares a documented figure with the best documented figure of the same kind. It does not count owner reviews, and it is not a verdict on product quality or on how many people have reviewed it. A low score can mean little is documented, or that a documented figure is below the best of its kind. Undisclosed data scores 0.
Missing details. This number counts only the evidence recorded so far. The source review for this product is not finished, or the maker has not disclosed enough, so the number can only go up.
Missing for this product: Certificates evidence needed; Warranty energy disclosure evidence needed; Cell model disclosure evidence needed.
High voltage · Industrial cabinet · Rated capacity
The warranty term and the lifetime energy are each scored against the best documented value for a home storage battery: a value earns its share of that best, times the weight. A documented value always earns points; an undisclosed one earns 0.
Product warranty on the electronics and enclosure, printed as "GOODWE warrants for five (5) years from the warranty start date, that the hardware of electronics and enclosure" in the GOODWE Limited Warranty for BAT 102.4&112.6kWh Energy Storage system (for Global Market) (Rev: 1.1 20250904), captured on September 25, 2026. The policy's Geographical Scope clause limits it to devices bought from authorized channels and installed in the international market it defines, which excludes the regions GoodWe covers with separate terms (the United States and Canada among them).
Research pending, 0 points: Certificates, Warranty energy disclosure, Cell model disclosure.
Computed from public specifications and evidence records. Warranty duration is not service quality; certificate evidence points are not a safety rating. Compatibility and installation limits still apply.
What this shows: what each record says and how far it reaches. It does not mean the product is approved.
Unknown: no certification evidence recorded in this data.
Warranty
Field
Value
Conditions
Source
Retention
70 %
Performance warranty, printed as "the Energy Storage system retains either seventy percent (70%) of *Usable Energy within ten (10) years from the warranty start date" in the GOODWE Limited Warranty for BAT 102.4&112.6kWh Energy Storage system (for Global Market) (Rev: 1.1 20250904), captured on September 25, 2026: 70% of usable energy for ten years or until the minimum throughput, whichever comes first. The performance warranty term (10 years) differs from the product warranty term.
Global-market policy; not the United States or Canada
Product warranty on the electronics and enclosure, printed as "GOODWE warrants for five (5) years from the warranty start date, that the hardware of electronics and enclosure" in the GOODWE Limited Warranty for BAT 102.4&112.6kWh Energy Storage system (for Global Market) (Rev: 1.1 20250904), captured on September 25, 2026. The policy's Geographical Scope clause limits it to devices bought from authorized channels and installed in the international market it defines, which excludes the regions GoodWe covers with separate terms (the United States and Canada among them).
Location: 2.2.2.3 and 9.2.3 BAT-C Series 61.4-112.6kWh C&I Battery System
Retrieved Sep 28, 2026
GoodWe's system user manual for its ET 15-30kW hybrid inverters and the batteries used with them, linked as "ET30+BAT-C" from the BAT-C 60-112kWh page. Captured September 29, 2026. Section 9.2.3 prints the BAT-C Series 61.4-112.6kWh Technical Data with a GW92.1-BAT-AC-G10 column. Manufacturer claims, not independently verified.
Archived copies
Archived copy of a document published by GoodWe Technologies Co., Ltd.. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Captured by scripts/prepare-brand-sweep-sep21.mjs on 2026-09-25.
Location: Technical Data table, one column per model
Retrieved Sep 24, 2026
GoodWe family datasheet (BAT 60-112 Series), fetched from en.goodwe.com (the file the series page en.goodwe.com/bat-60-112-series links as "Datasheet") and archived on September 25, 2026. Its Technical Data table sets the models side by side, one column per model, so each figure is read from the named model column and the whole row is quoted; a value printed once spans every column. It names models, not ordering SKUs. It is a manufacturer claim; no figure was tested independently.
Archived copies
Archived copy of a document published by GoodWe. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Captured by scripts/prepare-brand-sweep-sep21.mjs on 2026-09-25.
Location: Overview and Geographical Scope
Retrieved Sep 24, 2026
GoodWe limited warranty naming the BAT energy storage systems GW61.4-BAT-AC-G10, GW92.1-BAT-AC-G10, GW102.4-BAT-AC-G10 and GW112.6-BAT-AC-G10. Fetched from en.goodwe.com (linked from en.goodwe.com/warranty) and archived on September 25, 2026. The policy's Geographical Scope clause limits it to devices bought from authorized channels and installed in the international market it defines, which excludes the regions GoodWe covers with separate terms (the United States and Canada among them). It is the manufacturer's published policy, not a purchaser-specific contract.
Archived copies
Archived copy of a document published by GoodWe. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Earlier revisions, archived captures and copies published by someone other than the manufacturer. Every one stays reachable.
Archived documents
GoodWe BAT 60-112 Series datasheet (GoodWe-Single page-20260313-EN-V2.1)
Archived copy of a document published by GoodWe. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
GOODWE Limited Warranty for BAT 102.4&112.6kWh Energy Storage system (for Global Market), Rev: 1.1 20250904
Archived copy of a document published by GoodWe. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Commercial Smart Inverter Solutions user manual, ET 15-30kW systems (GoodWe, V2.2, 2026-05-25)
Archived copy of a document published by GoodWe Technologies Co., Ltd.. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Product prices and availability are accurate as of the date/time indicated and are subject to change. Any price and availability information displayed on Amazon.com at the time of purchase will apply to the purchase of this product. CERTAIN CONTENT THAT APPEARS ON THIS SITE COMES FROM AMAZON. THIS CONTENT IS PROVIDED ‘AS IS’ AND IS SUBJECT TO CHANGE OR REMOVAL AT ANY TIME.