The reviewed exact-model sources do not establish terminals for FranklinWH aPower S.
No source on record
Weight
176 kg / 388 lb converted
Printed as "Weight 388 lbs. (176 kg)" in FranklinWH's System Installation Guide for aPower S, aGate X 1.3 & 1.3.1 and the floor mounting bracket (V1.2.3, September 24, 2026), Appendix 2: Datasheet aPower S, Others; PDF page 16 prints "Weight, aPower S Complete 388 lb. (176 kg)" and "Weight, without Cover 365 lb. (166 kg)". Re-cited on 1 October 2026 to the manufacturer's own document; previously cited to FranklinWH (franklinwh.com), which stays listed as an additional source.
The reviewed exact-model sources do not establish cycle life for FranklinWH aPower S.
No source on record
Capacity
Unknown
The reviewed exact-model sources do not establish capacity ah for FranklinWH aPower S.
No source on record
Self heating
Unknown
The reviewed exact-model sources do not establish self heating for FranklinWH aPower S.
No source on record
Surge output
15 kW @ 10 S
Printed as "Maximum peak output power 15 kW @ 10 S" in FranklinWH's System Installation Guide for aPower S, aGate X 1.3 & 1.3.1 and the floor mounting bracket (V1.2.3, September 24, 2026), Appendix 2: Datasheet aPower S, AC Terminal, Bi-Directional (Off-Grid); the next row prints "Maximum transient load capacity 25 kW @ 1 S".
Where: PDF page 84, Appendix 2: Datasheet aPower S, AC Terminal (Off-Grid), Maximum peak output power row
≥ 6 in. (0.15 m) from the top of aPower to the ceiling; 4 in. (0.1 m) between adjacent aPower units and from side wall
Printed as "There should be a minimum clearance of 6 in. (0.15 m) from the top of aPower to the ceiling." in FranklinWH's System Installation Guide for aPower S, aGate X 1.3 & 1.3.1 and the floor mounting bracket (V1.2.3, September 24, 2026), Site Planning, aPower paragraph, which adds "The minimum clearance between adjacent aPower units and from side wall is 4 in. (0.1 m)." FranklinWH recommends 14 inches for tool access; PDF page 19 prints further minimums for vertical and front-to-back stacking.
Where: PDF page 18, Installation Preparations, Site Planning, aPower
W 750 × H 1,149 × D 300 mm / W 29.5 × H 45.24 × D 11.8 in converted
Printed as "Dimensions (H x W x D) 45.2 in. x 29.5 in. x 11.8 in. (1149 mm x 750 mm x 300 mm)" in FranklinWH's System Installation Guide for aPower S, aGate X 1.3 & 1.3.1 and the floor mounting bracket (V1.2.3, September 24, 2026), Appendix 2: Datasheet aPower S, Others; the same figures are printed under Mechanical Specifications on PDF page 16. Re-cited on 1 October 2026 to the manufacturer's own document; previously cited to FranklinWH (franklinwh.com), which stays listed as an additional source.
Where: PDF page 85, Appendix 2: Datasheet aPower S, Others, Dimensions (H x W x D) row
The reviewed exact-model sources do not establish emergency stop for FranklinWH aPower S.
No source on record
Solar input
15 kW
Printed as "Maximum photovoltaic input power 15 kW" in FranklinWH's System Installation Guide for aPower S, aGate X 1.3 & 1.3.1 and the floor mounting bracket (V1.2.3, September 24, 2026), Appendix 2: Datasheet aPower S, Solar Terminal; the table also prints "Maximum solar STC input 20 kW" and 4 MPPTs.
Where: PDF page 84, Appendix 2: Datasheet aPower S, Solar Terminal, Maximum photovoltaic input power row
The reviewed exact-model sources do not establish load start a lra for FranklinWH aPower S.
No source on record
Maximum charge
166 A
Printed as "Max. charging current (A) 166 A" in FranklinWH's System Installation Guide for aPower S, aGate X 1.3 & 1.3.1 and the floor mounting bracket (V1.2.3, September 24, 2026), Appendix 2: Datasheet aPower S, BAT DC Terminal, Bi-Directional.
Where: PDF page 84, Appendix 2: Datasheet aPower S, BAT DC Terminal, Max. charging current row
Printed as "Choose power cables in the 10 AWG to 6 AWG range based on the aPower's rated power specified in the utility contract." in FranklinWH's System Installation Guide for aPower S, aGate X 1.3 & 1.3.1 and the floor mounting bracket (V1.2.3, September 24, 2026), Connect the aPower(s) to the aGate, Cable Requirements, which also says "For all aPower connections, use only copper conductors rated for 194° F (90° C).".
Where: PDF page 59, Connect the aPower(s) to the aGate, Cable Requirements
The reviewed exact-model sources do not establish integrated busbar for FranklinWH aPower S.
No source on record
Nominal voltage
51.2 V
Printed as "Nominal voltage (V) 51.2 V" in FranklinWH's System Installation Guide for aPower S, aGate X 1.3 & 1.3.1 and the floor mounting bracket (V1.2.3, September 24, 2026), Appendix 2: Datasheet aPower S, BAT DC Terminal, Bi-Directional.
Where: PDF page 84, Appendix 2: Datasheet aPower S, BAT DC Terminal, Nominal voltage row
The reviewed exact-model sources do not establish nominal energy kwh for FranklinWH aPower S.
No source on record
AC output voltage
120/208 V, 120/240 V, 60 Hz
Printed as "Nominal AC voltage 120/208 V, 120/240 V, 60 Hz" in FranklinWH's System Installation Guide for aPower S, aGate X 1.3 & 1.3.1 and the floor mounting bracket (V1.2.3, September 24, 2026), Appendix 2: Datasheet aPower S, AC Terminal, Bi-Directional (Grid-Tied).
Where: PDF page 84, Appendix 2: Datasheet aPower S, AC Terminal (Grid-Tied), Nominal AC voltage row
The reviewed exact-model sources do not establish continuous charge a for FranklinWH aPower S.
No source on record
Maximum discharge
201 A
Printed as "Max. discharging current (A) 201 A" in FranklinWH's System Installation Guide for aPower S, aGate X 1.3 & 1.3.1 and the floor mounting bracket (V1.2.3, September 24, 2026), Appendix 2: Datasheet aPower S, BAT DC Terminal, Bi-Directional.
Where: PDF page 84, Appendix 2: Datasheet aPower S, BAT DC Terminal, Max. discharging current row
The reviewed exact-model sources do not establish charge temperature c for FranklinWH aPower S.
No source on record
Continuous output
11.5 kW
Printed as "11.5 kW continuous 10 kW continuous" in FranklinWH's System Installation Guide for aPower S, aGate X 1.3 & 1.3.1 and the floor mounting bracket (V1.2.3, September 24, 2026), Appendix 2: Datasheet aPower S, BAT DC Terminal, Max. discharging power row, whose two lines are "With PV Input" (11.5 kW continuous) and "Battery Only" (10 kW continuous); the AC Terminal (Grid-Tied) table prints nominal output power settings of 5 kW, 7.6 kW, 9.6 kW and 10 kW/11.5 kW. Re-cited on 1 October 2026 to the manufacturer's own document; previously cited to FranklinWH (franklinwh.com), which stays listed as an additional source.
Where: PDF page 84, Appendix 2: Datasheet aPower S, BAT DC Terminal, Max. discharging power row
≤24 hours: -22° F to 140° F (-30˚ C to +60˚ C) ≤ 9 months: -4° F to 113° F (-20˚ C to +45˚ C) ≤ 12 months: -4° F to 95° F (-20˚ C to +35˚ C) °C
Printed as "≤24 hours: -22° F to 140° F (-30˚ C to +60˚ C) ≤ 9 months: -4° F to 113° F (-20˚ C to +45˚ C) ≤ 12 months: -4° F to 95° F (-20˚ C to +35˚ C)" in FranklinWH's System Installation Guide for aPower S, aGate X 1.3 & 1.3.1 and the floor mounting bracket (V1.2.3, September 24, 2026), Appendix 2: Datasheet aPower S, Others, Storage temperature range row.
Where: PDF page 85, Appendix 2: Datasheet aPower S, Others, Storage temperature range row
The reviewed exact-model sources do not establish continuous ac output a for FranklinWH aPower S.
No source on record
Continuous discharge
Unknown
The reviewed exact-model sources do not establish continuous discharge a for FranklinWH aPower S.
No source on record
Discharge temperature
Unknown
The reviewed exact-model sources do not establish discharge temperature c for FranklinWH aPower S.
No source on record
Operating temperature
-20 to 50 °C / -4 to 122 °F converted
Printed as "-4° F to 122° F (-20˚ C to +50˚ C), derating above at +40˚ C" in FranklinWH's System Installation Guide for aPower S, aGate X 1.3 & 1.3.1 and the floor mounting bracket (V1.2.3, September 24, 2026), Appendix 2: Datasheet aPower S, Others, Operation temperature range row; output derates above +40˚ C.
Where: PDF page 85, Appendix 2: Datasheet aPower S, Others, Operation temperature range row
258.52 L* (Calculated enclosure volume: W × H × D in mm ÷ 1,000,000)W: 750 × H: 1,149 × D: 300 mm / W: 29.5 × H: 45.24 × D: 11.8 in176 kg / 388 lb0.06 kWh/L* (Rated or usable capacity shown on this card ÷ enclosure volume)
Evidence score
61/10095% documented
The Evidence score uses the priorities you choose. It counts published documents, such as certificates and warranty terms, and it compares a documented figure with the best documented figure of the same kind. It does not count owner reviews, and it is not a verdict on product quality or on how many people have reviewed it. A low score can mean little is documented, or that a documented figure is below the best of its kind. Undisclosed data scores 0.
Missing for this product: Cell model disclosure evidence needed.
AC-coupled · Wall / floor · Usable capacity
The warranty term and the lifetime energy are each scored against the best documented value for a home storage battery: a value earns its share of that best, times the weight. A documented value always earns points; an undisclosed one earns 0.
CertificatesUL 9540 · UL 1973Claimed13.78 / 45
30.63 evidence points · 45% weight
UL 9540: strongest qualifying evidence, counted once. Product-scoped manufacturer claim; issuer verification pending. Applies: CEC; UL 9540; UL 1973.
Computed from public specifications and evidence records. Warranty duration is not service quality; certificate evidence points are not a safety rating. Compatibility and installation limits still apply.
The reviewed exact-model sources do not establish warranty labor shipping for FranklinWH aPower S.
No source on record
Warranted throughput
60 MWh
Capacity-retention commitment ends at the stated warranty term or 60 MWh aggregate energy throughput, whichever occurs first. The contract does not identify the AC/DC measurement boundary; authorized-sale, certified-installation, and use conditions apply.
Where: Page 4, aPower 2/aPower S Performance Warranty table
Location: PDF page 1 cover (aPower S, SKU: APRS-10K15V1-US); PDF pages 84 and 85, Appendix 2: Datasheet aPower S; PDF page 88 revision history
Retrieved Oct 1, 2026
FranklinWH's own system installation guide for the aPower S (SKU APRS-10K15V1-US) with the aGate X 1.3 and 1.3.1, captured 1 October 2026 from franklinwh.com, where FranklinWH's documentation center lists it among its installation guides. Revision V1.2.3 dated September 24, 2026 as printed; Appendix 2 reprints the aPower S datasheet. Manufacturer instructions, not independent tests.
Archived copies
Archived copy of a document published by FranklinWH Energy Storage Inc.. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Archived copy of a document published by FranklinWH. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Archived copy of a document published by FranklinWH. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Matched to the catalog record because the catalog model designation appears in this page's own title and on no other page captured from this site.
Location: Page title: aPower S Home Battery: Advanced Energy Storage Innovation
Retrieved Sep 19, 2026
Manufacturer-operated product page, captured byte for byte with a plain HTTPS GET and a desktop user agent. It establishes what the manufacturer published at this URL on the access date for this exact model: the specification table it shows, the page photo and the documents it links. Values rendered only by client-side scripts are not part of the capture. Marketing text, certification wording and stock state remain manufacturer claims that were not independently verified, and nothing on it was applied to any other model.
Archived copy of a document published by FranklinWH. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Archived copy of a document published by FranklinWH. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
FranklinWH System Installation Guide, aPower S, aGate X 1.3 & aGate X 1.3.1 and floor mounting bracket (V1.2.3, September 24, 2026)
Archived copy of a document published by FranklinWH Energy Storage Inc.. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
No sourced accessories or replacement parts listed yet.
Model history
Model identity
Model
aPower S
Manufacturer SKU APRS-10K15V1-US · US market
No historical observations recorded yet.
Other recorded fields
Field
Value
Conditions
Source
Hardware revision
Unknown
The reviewed exact-model sources do not establish the physical hardware revision for FranklinWH aPower S.
No source on record
Country of manufacture
Unknown
The reviewed exact-model sources do not establish country of manufacture for FranklinWH aPower S.
No source on record
Manufacturer legal entity
Unknown
The reviewed exact-model sources do not establish the manufacturing legal entity for FranklinWH aPower S.
No source on record
Evidence breakdown
method version: 0.21-personal
documented pct: 95
basis: usable
missing:
Cell model disclosure evidence needed
criteria:
key: certificateEvidence
label: Certificates
value: 30.625
unit: evidence points
shown: UL 9540 · UL 1973
shown detail: Claimed
state: claimed
points: 13.78
ceiling: 45
weight: 45
share: 30.6
covered: yes
missing: no
folded: no
reason: Unknown
reason text: Unknown
note: UL 9540: strongest qualifying evidence, counted once. Product-scoped manufacturer claim; issuer verification pending. Applies: CEC; UL 9540; UL 1973.