Charged Reviews · Quick reference
Fox ESS EQ5000-M-P Battery Module
- Brand
- Fox ESS
- Model
- EQ5000-M-P
- SKU / part number
- ?
- Category
- Batteries
Energy and chemistry
| Nominal voltage | 44.8 V[1] |
|---|---|
| Rated capacity | 111 Ah[1] |
| Nominal energy | 4.97 kWh[1] |
| Usable energy | ? |
| Chemistry | Lithium Iron Phosphate[1] |
| Cell format | ? |
Charge and discharge
| Continuous charge current | 50 A[1] |
|---|---|
| Continuous discharge current | 50 A[1] |
| Maximum charge current | 50 A[1] |
| Maximum discharge current | 50 A[1] |
| Peak charge current | ? |
| Peak discharge current | 65 A[1] |
| Continuous output power | ? |
| Peak output | ? |
| Maximum charge voltage | ? |
| Charge cutoff voltage | ? |
| Discharge cutoff voltage | ? |
BMS and communication
| BMS continuous current | ? |
|---|---|
| Communication protocols | CAN[1] |
| Wireless monitoring | ? |
| Inverter compatibility | ? |
Operating temperature
| Charging temperature | 0 to 55 °C[1] |
|---|---|
| Discharging temperature | -10 to 55 °C[1] |
| Storage temperature | -10 to 35 °C[1] |
| Self-heating | ? |
Mechanical and mounting
| Dimensions | 380 D × 570 W × 188 H mm[1] |
|---|---|
| Weight | 44 kg / 97 lb[1] |
| Terminals | ? |
| Mounting / format | ? |
| Enclosure rating (IP) | ? |
Installation (from the manual)
Torque
| Main terminal torque | ? |
|---|---|
| Communication terminal torque | 1.2±0.2[1] |
| Ground terminal torque | ? |
Protection
| Fuse or breaker | Internal Short Circuit, Over Voltage, Over Current, Over Temp, Under Voltage.[1] |
|---|
Clearances and orientation
| Installation clearances | Rear: ≥20 mm; Top: ≥300 mm; Left: ≥300 mm; Right: ≥300 mm[1] |
|---|---|
| Mounting orientation | Stack the battery modules one by one.[1] |
Grounding
| Grounding | Before wiring, ensure the grounding cable (Item G) is securely connected.[1] |
|---|
Communication
| Communication ports | CAN; RJ45[1] |
|---|---|
| Address / DIP setting | ? |
Not in the manual: Conductors
System limits
| Maximum parallel units | ? |
|---|---|
| Series connection | ? |
| Maximum system energy | ? |
Page 1 of 2 · Installation values · ? means nothing is recordedAggregated, often community-reported information, not official documentation. Do not rely on it for installation, purchase or compliance decisions; always confirm values with the manufacturer’s official documentation. Charged Reviews accepts no responsibility for errors.