Charged ReviewsSaved 0Compare 0Login

Charged Reviews · Quick reference

Enphase IQ Battery 5P (United Kingdom, B05-T02-INT00-1-2)

Brand
Enphase
Model
IQ Battery 5P (B05-T02-INT00-1-2)
SKU / part number
IQBATTERY-5P-1P-INT [1]
Category
Batteries

chargedreviews.com/batteries/enphase-iq-battery-5p-uk

Energy and chemistry

Nominal voltage
76.8 V [1]
Rated capacity
?
Nominal energy
?
Usable energy
5 kWh [1]
Chemistry
Lithium iron phosphate (LFP) [1]
Cell format
?

Charge and discharge

Continuous charge current
?
Continuous discharge current
?
Maximum charge current
?
Maximum discharge current
?
Peak charge current
?
Peak discharge current
27.82 A [1]
Continuous output power
?
Peak output
27.82 A for 3 s; 22.26 A for 10 s [1]
Maximum charge voltage
?
Charge cutoff voltage
?
Discharge cutoff voltage
?

BMS and communication

BMS continuous current
?
Communication protocols
Wired control communication [1]
Wireless monitoring
?
Inverter compatibility
?

Operating temperature

Charging temperature
-20 to 50 °C / -4 to 122 °F converted [1]
Discharging temperature
-20 to 55 °C / -4 to 131 °F converted [1]
Storage temperature
?
Self-heating
?

Mechanical and mounting

Dimensions
W 550 × H 980 × D 188 mm / W 21.7 × H 38.6 × D 7.4 in converted [1]
Weight
78.9 kg / 174 lb converted Needs confirmation [2]
Terminals
?
Mounting / format
Wall-mount (included) or pedestal-mount (sold separately) [1]
Enclosure rating (IP)
Outdoor-IP55; IQ8D-BAT Microinverter Outdoor-IP67 [1]

Installation (from the manual)

Torque

Main terminal torque
2.5 N·m [3]
Communication terminal torque
0.2 N·m [3]
Ground terminal torque
1.5 N·m [3]

Protection

Fuse or breaker
20 A B curve breaker for one unit; max 80 A B curve for four on one circuit [3]

Clearances and orientation

Installation clearances
76 mm minimum between covers side-by-side; 250 mm minimum in front [3]
Mounting orientation
wall mount (pedestal accessory B05-PM-0550-O for floor mount); tilt from vertical less than 5° [3]

Grounding

Grounding
field Earth terminal, max 6 mm2 conductor [3]

Communication

Communication ports
Control connector (C1); Control connector (C2) [3]
Address / DIP setting
?

Not in the manual: Conductors

System limits

Maximum parallel units
?
Series connection
?
Maximum system energy
?
Page 1 of 2 · Installation values · ? means nothing is recordedAggregated, often community-reported information, not official documentation. Do not rely on it for installation, purchase or compliance decisions; always confirm values with the manufacturer’s official documentation. Charged Reviews accepts no responsibility for errors.

Charged Reviews · Quick reference

Enphase IQ Battery 5P (United Kingdom, B05-T02-INT00-1-2) · IQ Battery 5P (B05-T02-INT00-1-2)

Warranty

Warranty term15 years[1]
Warranty cycle limit6,000 cycles[1]
Warranted throughput?
Capacity retention?
Cycle rating?
Estimated throughput?
Coverage starts?
Coverage conditions?
Remedy?
Labor and shipping?
Transfer to another owner?
Registration?

Certifications and listings

UL 1973?
UL 9540?
UL 9540AClaimed present at observation [1]
UN 38.3Claimed present at observation [1]
IEC 62619Claimed present at observation [1]
CEClaimed present at observation [1]
Battery Directive 2006/66/ECClaimed present at observation [1]
Electro Magnetic Compatibility (EMC) Directive 2014/30/EUClaimed present at observation [1]
EN 50065-1Claimed present at observation [1]
EN 50065-2-2Claimed present at observation [1]
EN 55011:2016+A11:2020Claimed present at observation [1]
EN 61000-3Claimed present at observation [1]
EN 61000-6 EMCClaimed present at observation [1]
EN 62040-1Claimed present at observation [1]
EN IEC 62109-1 & 2Claimed present at observation [1]
G100-2Claimed present at observation [1]
G98Claimed present at observation [1]
G98 NIClaimed present at observation [1]
G99Claimed present at observation [1]
G99 NIClaimed present at observation [1]
IEC 61326-1Claimed present at observation [1]
IEC/EN 62116Claimed present at observation [1]
Low Voltage Directive (LVD) 2014/35/EUClaimed present at observation [1]
Restriction of Hazardous Substances (RoHS), 2011/65/EUClaimed present at observation [1]

Documents and sources

  1. Enphase IQ Battery 5P United Kingdom data sheet (DSH-00857-1.0-EN-2025-07-18) Manufacturer data sheet (PDF) · Revision DSH-00857-1.0-EN-2025-07-18 · Checked Sep 27, 2026 https://enphase.com/en-gb/download/iq-battery-5p-data-sheet
  2. Enphase IQ Battery 5P quick install guide, IQBATTERY-5P-1P-INT (140-00333-06, version 6.0, April 2026) Manufacturer installation/instruction manual · Checked Oct 12, 2026 https://enphase.com/en-gb/download/iq-battery-5p-quick-install-guide
  3. Enphase: IQ Battery 5P quick install guide (en-gb, 140-00333-06) Manufacturer manual (PDF) · Checked Oct 15, 2026 https://enphase.com/en-gb/download/iq-battery-5p-quick-install-guide

Unofficial reference. Information may be incorrect. This sheet aggregates the public sources listed above, much of it community-reported. It is not official manufacturer documentation, not an installation guide and not a compliance record. Community-reported values are checked against official manufacturer information before publication; we cannot guarantee accuracy or completeness. Do not rely on this sheet for installation, purchase or compliance decisions: always confirm every value with the manufacturer’s official documentation before buying, wiring or installing equipment. Charged Reviews accepts no responsibility for errors or omissions. Manufacturers can submit documents or corrections.

Page 2 of 2 · Charged Reviews LLC · chargedreviews.com/batteries/enphase-iq-battery-5p-ukSome links pay us a commission. That does not affect what we record.