Charged Reviews · Quick reference
ECO-WORTHY Cubix100 48V 100Ah Server Rack Battery (UK, UK-L12L100ACUB100-1)
- Brand
- ECO-WORTHY
- Model
- ECO-LFP4810002
- SKU / part number
- UK-L12L100ACUB100-1[2]
- Category
- Batteries

Energy and chemistry
| Nominal voltage | 51.2 V[1, 2] |
|---|---|
| Rated capacity | 100 Ah[1, 2] |
| Nominal energy | 5.12 kWh[1, 2] |
| Usable energy | 5.12 kWh[1] |
| Chemistry | ? |
| Cell format | ? |
Charge and discharge
| Continuous charge current | 50 A[1] |
|---|---|
| Continuous discharge current | 50 A[1] |
| Maximum charge current | 100 A[1, 2] |
| Maximum discharge current | 100 A[1, 2] |
| Peak charge current | ? |
| Peak discharge current | ? |
| Continuous output power | ? |
| Peak output | ? |
| Maximum charge voltage | 58.4 V[1, 2] |
| Charge cutoff voltage | ? |
| Discharge cutoff voltage | 40 V[1] |
BMS and communication
| BMS continuous current | ? |
|---|---|
| Communication protocols | RS485; CAN; RS232[1] |
| Wireless monitoring | Yes[1, 2] |
| Inverter compatibility | Default protocol PYLON; supported mainstream brands: SRNE, VICTRON, DEYE, LUXPOWER, GOODWE[1] |
Operating temperature
| Charging temperature | 0 to 55 °C[1, 2] |
|---|---|
| Discharging temperature | -20 to 55 °C[1] |
| Storage temperature | -20 to 25 °C[1] |
| Self-heating | ? |
Mechanical and mounting
| Dimensions | 561 D × 483 D × 143 D mm[1]Needs confirmation |
|---|---|
| Weight | 47 kg / 103.62 lb[1]Needs confirmation |
| Terminals | M8[2] |
| Mounting / format | Rack mounted (inserted into a rack slot)[1] |
| Enclosure rating (IP) | ? |
Installation (from the manual)
Conductors
| Cable size | 2/0 AWG battery-to-inverter cables (sold separately); 2 AWG battery-to-battery parallel cables (included)[1] |
|---|
Protection
| Fuse or breaker | 125 A breaker with shunt release[1] |
|---|
Clearances and orientation
| Installation clearances | ? |
|---|---|
| Mounting orientation | Never upside down or face down[1] |
Grounding
| Grounding | Included grounding wire connects the casings of all batteries in series[1] |
|---|
Communication
| Communication ports | RS485-1: host computer or inverter; CAN: inverter; RS232: host computer or inverter; RS485-2 and RS485-3: communication between batteries[1] |
|---|---|
| Address / DIP setting | DIP switch address (ADD) on the BMS per pack; up to 32 packs in parallel[1] |
Not in the manual: Torque
System limits
| Maximum parallel units | 32 batteries[1] |
|---|---|
| Series connection | ? |
| Maximum system energy | ? |
Page 1 of 2 · Installation values · ? means nothing is recordedAggregated, often community-reported information, not official documentation. Do not rely on it for installation, purchase or compliance decisions; always confirm values with the manufacturer’s official documentation. Charged Reviews accepts no responsibility for errors.