About brandDyness Digital Energy Technology Co., Ltd. says on its Company Profile page that it was established in 2017 and specializes in the research, development, production and sales of energy storage systems for residential, commercial and industrial use. Its site lists its address in Suzhou, China, and Dyness USA runs the dyness.us storefront.
SKU detail
locator: PDF page 1, cover; PDF page 9, Table 2-1 heading row; warranty page 1, section 2
conditions: The manual's Table 2-1 heads a column T7-US; the cover prints "Tower T7/T10/T14/T17/T21-US" and the warranty names "Tower T7-US ESS unit".
Printed as "LFP" in the Cell Technology row. Table 2-1 prints one column per model in the order T21-US, T17-US, T14-US, T10-US, T7-US; the T7-US value is column 5.
Where: PDF page 9 (printed page 7), Table 2-1 The Parameter of Tower-US System, T7-US column
Converted from the printed 232 lb using exactly 0.45359237 kg/lb. The Tower US Series sheet prints 231lbs. Table 2-1 prints one column per model in the order T21-US, T17-US, T14-US, T10-US, T7-US; the T7-US value is column 5.
Printed as 37 in the Battery System Capacity (Ah) row. Table 2-1 prints one column per model in the order T21-US, T17-US, T14-US, T10-US, T7-US; the T7-US value is column 5.
Where: PDF page 9 (printed page 7), Table 2-1 The Parameter of Tower-US System, T7-US column
W 502.92 × H 701.04 × D 381 mm / W 19.8 × H 27.6 × D 15 in converted
Converted from the printed Size [in/W*H*D] 19.8*27.6*15 using exactly 25.4 mm/in. The Tower US Series sheet prints 19.8*14.9*27.5 [W*D*H, inch]. Table 2-1 prints one column per model in the order T21-US, T17-US, T14-US, T10-US, T7-US; the T7-US value is column 5.
Printed as 4X in the NEMA Grade row. Table 2-1 prints one column per model in the order T21-US, T17-US, T14-US, T10-US, T7-US; the T7-US value is column 5.
Printed as 30 in the Battery System Max. Charge & Discharge Current [A] row, "in communication with the inverter". The same table prints 7.4 A (Standard) and 18.5 A (Normal) charge and discharge currents. Table 2-1 prints one column per model in the order T21-US, T17-US, T14-US, T10-US, T7-US; the T7-US value is column 5.
Where: PDF page 9 (printed page 7), Table 2-1 The Parameter of Tower-US System, T7-US column
Printed as 192 in the Battery System Voltage (Vdc) row; the module configuration row prints 2 Series of the HV9637 module. Table 2-1 prints one column per model in the order T21-US, T17-US, T14-US, T10-US, T7-US; the T7-US value is column 5.
Where: PDF page 9 (printed page 7), Table 2-1 The Parameter of Tower-US System, T7-US column
Printed as 6.39 in the Usable Energy [kWh] row, at the manual's 90% max depth of discharge. Table 2-1 prints one column per model in the order T21-US, T17-US, T14-US, T10-US, T7-US; the T7-US value is column 5.
Where: PDF page 9 (printed page 7), Table 2-1 The Parameter of Tower-US System, T7-US column
Printed as 7.10 in the Total Storing Energy [kWh] row. The Tower US Series sheet prints 7.10kWh. Table 2-1 prints one column per model in the order T21-US, T17-US, T14-US, T10-US, T7-US; the T7-US value is column 5.
Where: PDF page 9 (printed page 7), Table 2-1 The Parameter of Tower-US System, T7-US column
Printed as 5.82 in the Max. Charge & Discharge Power [kW] row, "in communication with the inverter". The Tower US Series sheet prints 4.26kW as the maximum continuous charge power, which its footnote ties to 0.6C. Table 2-1 prints one column per model in the order T21-US, T17-US, T14-US, T10-US, T7-US; the T7-US value is column 5.
Printed as 30 in the Battery System Max. Charge & Discharge Current [A] row, "in communication with the inverter". The same table prints 7.4 A (Standard) and 18.5 A (Normal) discharge currents. Table 2-1 prints one column per model in the order T21-US, T17-US, T14-US, T10-US, T7-US; the T7-US value is column 5.
Where: PDF page 9 (printed page 7), Table 2-1 The Parameter of Tower-US System, T7-US column
Printed as 168~219 in the Voltage Range [Vdc] row. Table 2-1 prints one column per model in the order T21-US, T17-US, T14-US, T10-US, T7-US; the T7-US value is column 5.
Where: PDF page 9 (printed page 7), Table 2-1 The Parameter of Tower-US System, T7-US column
Converted from the printed 32~113 F (Charge Temperature Condition [oF]), exactly. The Tower US Series sheet prints 32 to 122 F; the manual's value is recorded. Table 2-1 prints one column per model in the order T21-US, T17-US, T14-US, T10-US, T7-US; the T7-US value is column 5.
Converted from the printed 41~113 F for long-term storage (more than 3 months) of the battery cells, relative humidity below 65%, charged to 50 to 55% SOC before storage. The next sentence prints the module range as 41~113oC; the Fahrenheit reading, which matches the cells line, is recorded.
Where: PDF page 29 (printed page 27), 5 Storage Recommendations
Printed as 90% in the Max Depth of Discharge row. The Tower US Series sheet prints 100%; the manual's value is recorded. Table 2-1 prints one column per model in the order T21-US, T17-US, T14-US, T10-US, T7-US; the T7-US value is column 5.
Where: PDF page 9 (printed page 7), Table 2-1 The Parameter of Tower-US System, T7-US column
Printed as 5.82 in the Max. Charge & Discharge Power [kW] row, "in communication with the inverter". The Tower US Series sheet prints 4.26kW as the maximum continuous discharge power, which its footnote ties to 0.6C. Table 2-1 prints one column per model in the order T21-US, T17-US, T14-US, T10-US, T7-US; the T7-US value is column 5.
Printed as 219 in the Battery System Charge Voltage (Vdc) row. Table 2-1 prints one column per model in the order T21-US, T17-US, T14-US, T10-US, T7-US; the T7-US value is column 5.
Where: PDF page 9 (printed page 7), Table 2-1 The Parameter of Tower-US System, T7-US column
Converted from the printed 14~122 F (Discharge Temperature Condition [oF]), exactly. Table 2-1 prints one column per model in the order T21-US, T17-US, T14-US, T10-US, T7-US; the T7-US value is column 5.
Printed as 168 in the Battery System Discharge lower-Voltage (Vdc) row. Table 2-1 prints one column per model in the order T21-US, T17-US, T14-US, T10-US, T7-US; the T7-US value is column 5.
Where: PDF page 9 (printed page 7), Table 2-1 The Parameter of Tower-US System, T7-US column
134.33 L* (Calculated enclosure volume: W × H × D in mm ÷ 1,000,000)W: 502.92 × H: 701.04 × D: 381 mm / W: 19.8 × H: 27.6 × D: 15 in105.23 kg / 232 lb0.05 kWh/L* (Rated or usable capacity shown on this card ÷ enclosure volume)
Evidence score
9/100Missing details20% documented
The Evidence score uses the priorities you choose. It counts published documents, such as certificates and warranty terms, and it compares a documented figure with the best documented figure of the same kind. It does not count owner reviews, and it is not a verdict on product quality or on how many people have reviewed it. A low score can mean little is documented, or that a documented figure is below the best of its kind. Undisclosed data scores 0.
Missing details. This number counts only the evidence recorded so far. The source review for this product is not finished, or the maker has not disclosed enough, so the number can only go up.
Missing for this product: Certificates evidence needed; Warranty energy disclosure evidence needed; Lifetime / capacity evidence needed; Cell model disclosure evidence needed.
High voltage · Format not recorded · Rated capacity
The warranty term and the lifetime energy are each scored against the best documented value for a home storage battery: a value earns its share of that best, times the weight. A documented value always earns points; an undisclosed one earns 0.
Printed as "seven (7) years from the sales date" on the seller's invoice; extendable to ten years if the customer registers on Dyness's website and Dyness approves; five (5) years for products used without a communication connection. Covers the equivalent of one full cycle per day. North America terms dated 20230630.
Research pending, 0 points: Certificates, Cell model disclosure.
Computed from public specifications and evidence records. Warranty duration is not service quality; certificate evidence points are not a safety rating. Compatibility and installation limits still apply.
Printed as "seven (7) years from the sales date" on the seller's invoice; extendable to ten years if the customer registers on Dyness's website and Dyness approves; five (5) years for products used without a communication connection. Covers the equivalent of one full cycle per day. North America terms dated 20230630.
Where: Page 1, section 3 Product Warranty, Warranty Period
70% of nominal energy for ten years from the invoice date or the minimum energy throughput in Table 4-1, whichever occurs first, used per the warranty's Appendix 1.
Location: PDF page 1, cover; PDF pages 9 and 10 (printed pages 7 and 8), Table 2-1 The Parameter of Tower-US System
Retrieved Oct 28, 2026
Dyness's own 30-page Tower-US user manual, served from its US store's file host and linked from its US download center. The cover prints "Tower T7/T10/T14/T17/T21-US" and "File version-20230803-V2-EN". Table 2-1 (PDF pages 9 and 10, printed pages 7 and 8) prints one column per model. Page 3 restricts excerpting or reproducing the document without Dyness's written authorization; this record cites it and copies no figures. Manufacturer claims, not independent tests.
Archived copies
Archived copy of a document published by Dyness. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Location: Page 1, sections 2 and 3; page 2, section 4 and Table 4-1
Retrieved Oct 28, 2026
Dyness's own 8-page North America limited warranty for the Tower-US series, served from its US store's file host; the header prints "20230630" and section 2 names Tower T7-US, T10-US, T14-US, T17-US and T21-US ESS units. Table 4-1 prints T14-US nominal energy as 14.20 kWh where the user manual prints 14.21. Warranty terms as printed on that date, not a statement of current coverage.
Archived copies
Archived copy of a document published by Dyness. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Earlier revisions, archived captures and copies published by someone other than the manufacturer. Every one stays reachable.
Archived documents
Dyness Tower-US HV battery system user manual, Tower T7/T10/T14/T17/T21-US (file version 20230803-V2-EN)
Archived copy of a document published by Dyness. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Dyness Tower US Series product sheet (Tower T7-US, T10-US, T14-US)
Archived copy of a document published by Dyness. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Dyness Lithium Iron Phosphate Battery Limited Warranty (North America), Tower-US series, 20230630
Archived copy of a document published by Dyness. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].