Charged ReviewsSaved 0Compare 0Login

Duracell Power Center D-14kWh-LFP Battery Cabinet

Key specs

BrandDuracell Power Center
ModelD-14kWh-LFP
RegionUS
Nominal voltage44.5-53.5 V DC
Nominal energy14.2 kWh
ChemistryLithium Iron Phosphate (Pylontech US3000C modules)
Weight145 kg / 320 lb converted

All specifications

Show all 24 specifications

Identity

BrandDuracell Power Center · Website
ModelD-14kWh-LFP
RegionUS
Manufacturer SKUD-14kWh-LFP
About brandDuracell Power Center, whose site carries a Power Center copyright and whose datasheets give a San Jose, California address, sells home battery storage, hybrid inverters, microinverters and an EV charger under the Duracell trademark, which its site says is used under license from Duracell U.S. Operations, Inc. Its datasheets say the products are manufactured under license and warranty supported by Omega Green Power in San Jose.
SKU detail
locator: Section 2.6 component list; Table 3 model row
conditions: Duracell part number of the battery cabinet; Greentech prints it as D-14KWH-LFP.
Sources: [1]
FieldValueConditionsSource
ChemistryLithium Iron Phosphate (Pylontech US3000C modules)Exact table wording.
Where: Table 3, "Battery Mfr / model / chemistry"
[1]
GroundingDC negative grounded; internal ground lug with a 10 AWG ground home run per module
Printed as "Grounding terminal, DC negative grounded 70 mm2 (AWG 2/0)"; "Ground Lug (internal) - 10 AWG home run per module" in the Duracell Power Center 5 kW installation and startup manual (Power Center Essential LFP) (page 32, Tables 3 and 4).
Where: PDF page 32, Tables 3 and 4
[1]
Weight145 kg / 320 lb converted
Printed as 320 lbs (145 kg) including four battery modules.
Where: Table 3, "Weight (including 4 battery modules)"
[1]
DimensionsW 572 × H 1,041 × D 397 mm / W 22.5 × H 40.98 × D 15.6 in converted
Width x height x depth in millimeters as printed beside 22.5 x 41.0 x 15.6 in.
Where: Table 3, "Dimensions"
[1]
Mounting typeWall mounted beside the PCS cabinet on the wall mounting bracket
Printed as "Figure 5: Wall-mounting the cabinets." in the Duracell Power Center 5 kW installation and startup manual (Power Center Essential LFP) (page 14, section 4, Figure 5).
Where: PDF page 14, section 4, Figure 5
[1]
Battery format
Wall / floor
Site classificationBased onOfficial installation manual
Details

Charged Reviews classified this product from the documents it is based on. It is our own grouping, not a manufacturer claim.

Printed as "4 PCS AND BATTERY CABINET WALL-MOUNTING INSTRUCTIONS" and "Figure 5: Wall-mounting the cabinets.". Classified as Wall / floor from the maker's own words for this model.

Official installation manual: Duracell Power Center 5 kW installation and startup manual (Power Center Essential LFP)

Location: Duracell Power Center 5 kW installation and startup manual (Power Center Essential LFP), contents, page 5 and section 4, page 14

Enclosure ratingType 3RAs printed.
Where: Table 3, "Enclosure Rating"
[1]
Battery wire sizeMain DC up to 70 mm² (2/0 AWG)
Printed as "Max wire size of main DC 70 mm2 (AWG 2/0)" in the Duracell Power Center 5 kW installation and startup manual (Power Center Essential LFP) (page 32, Table 3 Battery Cabinet Electrical / Mechanical Ratings).
Where: PDF page 32, Table 3 Battery Cabinet Electrical / Mechanical Ratings
[1]
Nominal voltage44.5-53.5 V DC
The table prints no single nominal voltage; this is the DC voltage range at 100% output power. The operating range is printed as 0 to 80 V DC and the maximum as 80 V DC.
Where: Table 3, "DC Voltage Range at 100% Output Power"
[1]
Usable energy12.8 kWh
Usable capacity of the cabinet with four modules, printed as 3.2 kWh per module and 12.8 kWh for four.
Where: Table 3, "Battery module capacity / Usable capacity (x4 modules)"
[1]
Battery protectionCircuit breaker on the positive pole, 180 A or 175 A, UL 489
Printed as "Circuit Breaker, Positive Pole 180A or 175A, UL 489" in the Duracell Power Center 5 kW installation and startup manual (Power Center Essential LFP) (page 32, Table 3 Battery Cabinet Electrical / Mechanical Ratings).
Where: PDF page 32, Table 3 Battery Cabinet Electrical / Mechanical Ratings
[1]
Nominal energy14.2 kWh
Module capacity of the cabinet with four modules, printed as 3.55 kWh per module and 14.2 kWh for four.
Where: Table 3, "Battery module capacity / Usable capacity (x4 modules)"
[1]
Maximum discharge125 A
One figure, 125 A, is printed for both the maximum and the recommended DC current rating; the cabinet breaker is printed as 180A or 175A, UL 489.
Where: Table 3, "Max DC current rating / Recommended DC current rating"
[1]
Charge temperature0 to 50 °C / 32 to 122 °F converted
The row prints "0 to +50 °C charge / -10 to +50 °C charge"; the first range is recorded for charging. The second range, also labeled charge, is not recorded.
Where: Table 3, "Normal Operation Temperature Range"
[1]
Continuous output5 kW
Printed as 5000 W total in the battery cabinet table.
Where: Table 3, "Maximum Continuous Output Power (total)"
[1]
Storage temperature-20 to 60 °C / -4 to 140 °F convertedAs printed.
Where: Table 3, "Storage Temperature Range"
[1]
Ground terminal torque1.7 N·m
Printed as "Ground Lug (internal) - 10 AWG home run per module 1.7 (15)" in the Duracell Power Center 5 kW installation and startup manual (Power Center Essential LFP) (page 32, Table 4 Battery Cabinet Field Wiring Ratings). Printed as 1.7 N·m (15 in-lb).
Where: PDF page 32, Table 4 Battery Cabinet Field Wiring Ratings
[1]
Operating temperature-10 to 50 °C / 14 to 122 °F converted
Printed as "The battery modules are rated for operating temperature range between -10C to +50C." in the Duracell Power Center 5 kW installation and startup manual (Power Center Essential LFP) (page 13, section 3 Installation Site Preparation).
Where: PDF page 13, section 3 Installation Site Preparation
[1]
Other compliance claimsUL 9540, UL 1973
Exact table wording; manufacturer claims with no certificate numbers or certification bodies printed.
Where: Table 3, "Compliance Safety"
[1]

Owner reviews

No reviews. Be the first to review this product:
Write a review

Sellers

No listed sellers in this data.

Price history

No seller price history.

Evidence score

16/100Missing details45% documented

The Evidence score uses the priorities you choose. It counts published documents, such as certificates and warranty terms, and it compares a documented figure with the best documented figure of the same kind. It does not count owner reviews, and it is not a verdict on product quality or on how many people have reviewed it. A low score can mean little is documented, or that a documented figure is below the best of its kind. Undisclosed data scores 0.

Missing details. This number counts only the evidence recorded so far. The source review for this product is not finished, or the maker has not disclosed enough, so the number can only go up.

Missing for this product: Warranty term needed; Warranty energy disclosure evidence needed; Lifetime / capacity evidence needed; Cell model disclosure evidence needed.

Wall / floor · Rated capacity

The warranty term and the lifetime energy are each scored against the best documented value for a home storage battery: a value earns its share of that best, times the weight. A documented value always earns points; an undisclosed one earns 0.

CertificatesUL 1973 · UL 9540Claimed15.75 / 45

35 evidence points · 45% weight

UL 1973: strongest qualifying evidence, counted once. Product-scoped manufacturer claim; issuer verification pending. Applies: UL 1973; CEC not assessed without a documented voltage class; UL 9540 not assessed without a documented voltage class.

35 / 100 × 45 = 15.75 points.

[1]

Lifetime / capacityResearch pending0 / 20

No qualifying figure · 20% weight

Not published. No lifetime-production bonus.

Not documented. Undisclosed data scores 0.

[1]

Research pending, 0 points: Warranty term, Warranty energy disclosure, Cell model disclosure.

Computed from public specifications and evidence records. Warranty duration is not service quality; certificate evidence points are not a safety rating. Compatibility and installation limits still apply.

Certificates

What this shows: what each record says and how far it reaches. It does not mean the product is approved.
UL 1973manufacturer claimpresent at observation[1]
Scope
battery assembly
Covered models
D-14kWh-LFP
Limitations
Printed in the Compliance, Safety row of the battery cabinet ratings table (Table 3). The manual does not say whether the listing covers the cabinet or the Pylontech US3000C modules inside it. No certificate or issuer record was read.
Record detail
Issued: Not stated
Valid from: Not stated
Expiry: Not stated
Not checked
Source
[1]
UL 9540manufacturer claimpresent at observation[1]
Scope
system
Covered models
D-14kWh-LFP
Limitations
Printed in the Compliance, Safety row of the battery cabinet ratings table (Table 3); UL 9540 applies to an energy storage system, and the manual does not state which PCS and battery cabinet combination it covers. No certificate or issuer record was read.
Record detail
Issued: Not stated
Valid from: Not stated
Expiry: Not stated
Not checked
Edition as printed: Not printed
Source
[1]

Warranty

Unknown: no warranty facts recorded.

Recalls / legal notices

No recalls on file. All notices · Report a notice

This register is incomplete. A missing notice does not establish that a product has no recalls.

Documents

  • Manuals

  • Duracell Power Center 5 kW installation and startup manual (Power Center Essential LFP)Official · Power Center (Duracell Power Center) · Official installation manual · January 10, 2022 · PDF
    Certificate & compliance claims (2)
    UL 9540Manufacturer claim · systemClaimedListed when checked

    Printed in the Compliance, Safety row of the battery cabinet ratings table (Table 3); UL 9540 applies to an energy storage system, and the manual does not state which PCS and battery cabinet combination it covers. No certificate or issuer record was read.

    Manufacturer document

    Official installation manual: Duracell Power Center 5 kW installation and startup manual (Power Center Essential LFP)
    UL 1973Manufacturer claim · battery assemblyClaimedListed when checked

    Printed in the Compliance, Safety row of the battery cabinet ratings table (Table 3). The manual does not say whether the listing covers the cabinet or the Pylontech US3000C modules inside it. No certificate or issuer record was read.

    Manufacturer document

    Official installation manual: Duracell Power Center 5 kW installation and startup manual (Power Center Essential LFP)
    Source details
    Revision
    1.0 (draft)
    Revision date
    January 10, 2022

    Captured by scripts/prepare-brand-sweep-sep21.mjs on 2026-09-24.

    Location: Section 2.6 component list; Section 13 Tables 1 and 3

    Retrieved Sep 23, 2026

    Forty-four page installation and startup manual linked from the Resources page as the Power Center ESSENTIAL LFP Install & Startup Manual, archived on September 24, 2026. Its revision history shows only revision 1.0, a draft dated January 10, 2022. It names the system DURACELL POWER CENTER 5 kW, made of the D-5 kW PCS cabinet and the D-14kWh-LFP battery cabinet holding four Pylontech US3000C modules. Section 13 Tables 1 and 3 give the PCS and battery cabinet ratings. Its compliance rows are manufacturer claims that no issuer record was read against.

    Archived copies

    Archived copy of a document published by Power Center (Duracell Power Center). Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email legal@chargedreviews.com.

    Archived backupRevision not recorded · 4.05 MB

    Archived copy, unaltered, kept as a record of what Power Center (Duracell Power Center) published. Original address: https://duracellpowercenter.com/wp-content/uploads/2024/02/Power-Center-Essential-LFP-Install-Startup-Manual.pdf. Copyright and takedown

    Source first found
    This copy captured
    Archived
    File detailsOriginal source
    Embedded creation date
    Embedded modification date
    Pages
    44

    Embedded dates are file metadata, not independent proof of publication.

    SHA-256: b59c7e7b8d9141bdb7efdcec5d4ea9544f8db431cc5614c2d33f6bc8849a16a5

    Open
  • Other documents

  • Resources - Duracell Power Center (September 24, 2026 capture)Official · Power Center (Duracell Power Center) · Official product page · Web page
    Source details
    Revision
    Not stated
    Revision date
    Not stated

    Captured by scripts/prepare-brand-sweep-sep21.mjs on 2026-09-24.

    Location: Power Center, MA Series and M Series document lists

    Retrieved Sep 23, 2026

    Duracell Power Center Resources page, captured on September 24, 2026. It links the datasheets and manuals cited here (checked in the page markup) and prints no product figures.

    Open

Archive and older revisions

Archive and older revisions0

Earlier revisions, archived captures and copies published by someone other than the manufacturer. Every one stays reachable.

Archived documents

Duracell Power Center 5 kW installation and startup manual (Power Center Essential LFP)

Archived copy of a document published by Power Center (Duracell Power Center). Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email legal@chargedreviews.com.

Archived backupRevision not recorded · 4.05 MB

Archived copy, unaltered, kept as a record of what Power Center (Duracell Power Center) published. Original address: https://duracellpowercenter.com/wp-content/uploads/2024/02/Power-Center-Essential-LFP-Install-Startup-Manual.pdf. Copyright and takedown

Source first found
This copy captured
Archived
File detailsOriginal source
Embedded creation date
Embedded modification date
Pages
44

Embedded dates are file metadata, not independent proof of publication.

SHA-256: b59c7e7b8d9141bdb7efdcec5d4ea9544f8db431cc5614c2d33f6bc8849a16a5

Submit a document

Matched on printed specifications

Not documented: Nominal voltage.

Matched on printed specifications only: each manufacturer's datasheet, as recorded on the product pages. A match means one product's printed figure falls inside the other's printed limit. It does not mean the two have been shown to work together. A figure a manufacturer does not print shows as Not documented and is never assumed. This is not a test or an approval. A qualified installer and the local code decide what can be connected.

Parts and accessories

No sourced accessories or replacement parts listed yet.

Model history

Model identity

Model
D-14kWh-LFP

Manufacturer SKU D-14kWh-LFP · US market

No historical observations recorded yet.

Other recorded fields

FieldValueConditionsSource
Evidence breakdown
method version: 0.21-personal
documented pct: 45
basis: nominal
missing:
Warranty term needed
Warranty energy disclosure evidence needed
Lifetime / capacity evidence needed
Cell model disclosure evidence needed
criteria:
key: certificateEvidence
label: Certificates
value: 35
unit: evidence points
shown: UL 1973 · UL 9540
shown detail: Claimed
state: claimed
points: 15.75
ceiling: 45
weight: 45
share: 35
covered: yes
missing: no
folded: no
reason: Unknown
reason text: Unknown
note: UL 1973: strongest qualifying evidence, counted once. Product-scoped manufacturer claim; issuer verification pending. Applies: UL 1973; CEC not assessed without a documented voltage class; UL 9540 not assessed without a documented voltage class.
display note: Unknown
Sources: [1]
key: years
label: Warranty term
value: Unknown
unit: years
shown: Research pending
shown detail: Unknown
state: pending
points: 0
ceiling: 20
weight: 20
share: Unknown
covered: no
missing: yes
folded: yes
reason: undocumented
reason text: Not documented. Undisclosed data scores 0.
note: Not documented.
display note: Unknown
Sources: No source on record
key: throughputEvidence
label: Warranty energy disclosure
value: 0
unit: evidence points
shown: Research pending
shown detail: Unknown
state: pending
points: 0
ceiling: 10
weight: 10
share: 0
covered: no
missing: yes
folded: yes
reason: Unknown
reason text: Unknown
note: No qualifying quantified warranty energy recorded. This is an evidence gap, not a performance judgment.
display note: Unknown
Sources: No source on record
key: lifetime
label: Lifetime / capacity
value: Unknown
unit: MWh/kWh
shown: Research pending
shown detail: Unknown
state: pending
points: 0
ceiling: 20
weight: 20
share: Unknown
covered: no
missing: yes
folded: no
reason: undocumented
reason text: Not documented. Undisclosed data scores 0.
note: Not published. No lifetime-production bonus.
display note: Unknown
Sources: [1]
key: cellDisclosure
label: Cell model disclosure
value: 0
unit: disclosure points
shown: Research pending
shown detail: Unknown
state: pending
points: 0
ceiling: 5
weight: 5
share: 0
covered: no
missing: yes
folded: yes
reason: Unknown
reason text: Unknown
note: A sourced cell manufacturer and model are needed. Grade A, chemistry and cell capacity alone do not identify a cell model.
display note: Unknown
Sources: No source on record

Community discussions

No discussions linked yet. Search DIY Solar Forum

Sources

  1. Duracell Power Center 5 kW installation and startup manual (Power Center Essential LFP) (Power Center (Duracell Power Center) · manufacturer · observed Sep 23, 2026)

Sign in to report an error on this page

Similar products

All with a price

* Missing details