locator: Data sheet model row; product page specifications table
conditions: Printed in the model row "PAR-106 PAR-160 PAR-210 PAR-266 PAR-318 PAR-372 PAR-426" of the data sheet 808-0058 REV A (seventh column) and in the PAR Rack Systems Specifications table on the product page.
W 1,220 × H 2,285 × D 1,220 mm / W 48.03 × H 89.96 × D 48.03 in converted
An estimate as printed: "Estimated Product Dimensions - Pack&Rack (WxDxH) 1,220x1,220x600 mm 1,220x1,220x950 mm 1,220x1,220x1,220 mm 1,220x1,220x1,505 mm 1,220x1,220x1,765 mm 1,220x1,220x2,025 mm 1,220x1,220x2,285 mm"; PAR-426 is the seventh column (width by depth by height).
Where: Data sheet 808-0058 REV A, Estimated Product Dimensions row
Printed as "System Operating Voltage 312 - 358.8 V 468 - 538.2 V 624 - 717.6 V 780 - 897 V 936 - 1,076.4 V 1,092 - 1,255.8 V 1,248 - 1,435.2 V"; PAR-426 is the seventh column.
Where: Data sheet 808-0058 REV A, System Operating Voltage row
Printed as "Battery Max. Continuous Power 52 kW 79 kW 104 kW 131 kW 157 kW 183 kW 209 kW"; PAR-426 is the seventh column. DC, as printed for the battery.
Where: Data sheet 808-0058 REV A, Battery Max. Continuous Power row
3,400.99 L* (Calculated enclosure volume: W × H × D in mm ÷ 1,000,000)W: 1,220 × H: 2,285 × D: 1,220 mm / W: 48.03 × H: 89.96 × D: 48.03 in3,200 kg / 7,055 lb0.13 kWh/L* (Rated or usable capacity shown on this card ÷ enclosure volume)
Evidence score
11/100Missing details45% documented
The Evidence score uses the priorities you choose. It counts published documents, such as certificates and warranty terms, and it compares a documented figure with the best documented figure of the same kind. It does not count owner reviews, and it is not a verdict on product quality or on how many people have reviewed it. A low score can mean little is documented, or that a documented figure is below the best of its kind. Undisclosed data scores 0.
Missing details. This number counts only the evidence recorded so far. The source review for this product is not finished, or the maker has not disclosed enough, so the number can only go up.
Missing for this product: Warranty term needed; Warranty energy disclosure evidence needed; Lifetime / capacity evidence needed; Cell model disclosure evidence needed.
Industrial/Commercial ESS · High voltage · Over 100 kWh · Rated capacity
The warranty term and the lifetime energy are each scored against the best documented value for a home storage battery: a value earns its share of that best, times the weight. A documented value always earns points; an undisclosed one earns 0.
CertificatesUL 1973 · UL 9540AClaimed11.25 / 45
25 evidence points · 45% weight
UL 1973: strongest qualifying evidence, counted once. Product-scoped manufacturer claim; issuer verification pending. Applies: UL 9540; UL 1973; CEC not assessed for commercial and industrial equipment in this catalog. UL 9540A is recorded but not scored: a thermal-runaway test method, recorded as a documented report and never scored as a listing.
Research pending, 0 points: Warranty term, Warranty energy disclosure, Cell model disclosure.
Computed from public specifications and evidence records. Warranty duration is not service quality; certificate evidence points are not a safety rating. Compatibility and installation limits still apply.
What this shows: what each record says and how far it reaches. It does not mean the product is approved.
StandardEvidenceStatusSource
UL 1973manufacturer claimpresent at observation[1][2]
Scope
battery pack scope unverified
Covered models
PAR-426
Limitations
A manufacturer claim, not a listing or certificate. Printed in Discover Energy Systems' AES Packs & Racks data sheet 808-0058 REV A (one page, captured on October 13, 2026) as "Certified to UL 9540A, UL 1973, and IEC, each module delivers global safety and reliability" and in the "Certifications & Testing" row as "UL1973, UL9540A, IEC62619, IEC61000, GB/T36276, UN38.3". The sheet covers exactly the seven models PAR-106 to PAR-426, printed in its model row; the certifications row holds one value for all seven columns, so it reads for PAR-426. Discover's Packs & Racks page (captured the same day) prints the same sentence. The sentence attaches the claim to "each module" (the 52S1P packs the rack is built from), not to the assembled rack system. No issuer, certificate or report number is printed; the issuer's record was not checked.
UL 9540Amanufacturer claimpresent at observation[1][2]
Scope
battery pack scope unverified
Covered models
PAR-426
Limitations
A manufacturer claim, not a listing or certificate. Printed in Discover Energy Systems' AES Packs & Racks data sheet 808-0058 REV A (one page, captured on October 13, 2026) as "Certified to UL 9540A, UL 1973, and IEC, each module delivers global safety and reliability" and in the "Certifications & Testing" row as "UL1973, UL9540A, IEC62619, IEC61000, GB/T36276, UN38.3". The sheet covers exactly the seven models PAR-106 to PAR-426, printed in its model row; the certifications row holds one value for all seven columns, so it reads for PAR-426. Discover's Packs & Racks page (captured the same day) prints the same sentence. The sentence attaches the claim to "each module" (the 52S1P packs the rack is built from), not to the assembled rack system. UL 9540A is a fire test method; the data sheet prints no test report number and does not say at which level (cell, module or unit) the test was run. No issuer, certificate or report number is printed; the issuer's record was not checked.
UL 1973Manufacturer claim · battery pack scope unverifiedClaimedListed when checked
A manufacturer claim, not a listing or certificate. Printed in Discover Energy Systems' AES Packs & Racks data sheet 808-0058 REV A (one page, captured on October 13, 2026) as "Certified to UL 9540A, UL 1973, and IEC, each module delivers global safety and reliability" and in the "Certifications & Testing" row as "UL1973, UL9540A, IEC62619, IEC61000, GB/T36276, UN38.3". The sheet covers exactly the seven models PAR-106 to PAR-426, printed in its model row; the certifications row holds one value for all seven columns, so it reads for PAR-426. Discover's Packs & Racks page (captured the same day) prints the same sentence. The sentence attaches the claim to "each module" (the 52S1P packs the rack is built from), not to the assembled rack system. No issuer, certificate or report number is printed; the issuer's record was not checked.
UL 9540AManufacturer claim · battery pack scope unverifiedClaimedListed when checked
A manufacturer claim, not a listing or certificate. Printed in Discover Energy Systems' AES Packs & Racks data sheet 808-0058 REV A (one page, captured on October 13, 2026) as "Certified to UL 9540A, UL 1973, and IEC, each module delivers global safety and reliability" and in the "Certifications & Testing" row as "UL1973, UL9540A, IEC62619, IEC61000, GB/T36276, UN38.3". The sheet covers exactly the seven models PAR-106 to PAR-426, printed in its model row; the certifications row holds one value for all seven columns, so it reads for PAR-426. Discover's Packs & Racks page (captured the same day) prints the same sentence. The sentence attaches the claim to "each module" (the 52S1P packs the rack is built from), not to the assembled rack system. UL 9540A is a fire test method; the data sheet prints no test report number and does not say at which level (cell, module or unit) the test was run. No issuer, certificate or report number is printed; the issuer's record was not checked.
Discover Energy Systems' own one-page data sheet for the PAR-106 to PAR-426 pack-and-rack systems, captured on October 13, 2026 from discoverenergysys.com; revision 808-0058 REV A as printed. Each row prints the seven models' values in column order; dimensions and weights are printed as estimates. Manufacturer claims, not independent tests.
Archived copies
Archived copy of a document published by Discover Energy Systems. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Discover Energy Systems' own Packs & Racks page, captured on October 13, 2026. Its PAR Rack Systems Specifications table prints PAR-106 to PAR-426, and it publishes one image per pack count. It carries no revision or date.
Earlier revisions, archived captures and copies published by someone other than the manufacturer. Every one stays reachable.
Archived documents
Discover AES Packs & Racks Energy Storage Solution data sheet (808-0058 REV A)
Archived copy of a document published by Discover Energy Systems. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
No sourced accessories or replacement parts listed yet.
Model history
Model identity
Model
PAR-426
Manufacturer SKU PAR-426
Observed Oct 13, 2026
UL 1973: claimed
Battery pack claim; verification pending. A manufacturer claim, not a listing or certificate. Printed in Discover Energy Systems' AES Packs & Racks data sheet 808-0058 REV A (one page, captured on October 13, 2026) as "Certified to UL 9540A, UL 1973, and IEC, each module delivers global safety and reliability" and in the "Certifications & Testing" row as "UL1973, UL9540A, IEC62619, IEC61000, GB/T36276, UN38.3". The sheet covers exactly the seven models PAR-106 to PAR-426, printed in its model row; the certifications row holds one value for all seven columns, so it reads for PAR-426. Discover's Packs & Racks page (captured the same day) prints the same sentence. The sentence attaches the claim to "each module" (the 52S1P packs the rack is built from), not to the assembled rack system. No issuer, certificate or report number is printed; the issuer's record was not checked.
Battery pack claim; verification pending. A manufacturer claim, not a listing or certificate. Printed in Discover Energy Systems' AES Packs & Racks data sheet 808-0058 REV A (one page, captured on October 13, 2026) as "Certified to UL 9540A, UL 1973, and IEC, each module delivers global safety and reliability" and in the "Certifications & Testing" row as "UL1973, UL9540A, IEC62619, IEC61000, GB/T36276, UN38.3". The sheet covers exactly the seven models PAR-106 to PAR-426, printed in its model row; the certifications row holds one value for all seven columns, so it reads for PAR-426. Discover's Packs & Racks page (captured the same day) prints the same sentence. The sentence attaches the claim to "each module" (the 52S1P packs the rack is built from), not to the assembled rack system. UL 9540A is a fire test method; the data sheet prints no test report number and does not say at which level (cell, module or unit) the test was run. No issuer, certificate or report number is printed; the issuer's record was not checked.
note: UL 1973: strongest qualifying evidence, counted once. Product-scoped manufacturer claim; issuer verification pending. Applies: UL 9540; UL 1973; CEC not assessed for commercial and industrial equipment in this catalog. UL 9540A is recorded but not scored: a thermal-runaway test method, recorded as a documented report and never scored as a listing.