Printed as "D12-120W 12 120 30 27 23 165 125 175 8.80 F13M5" in Discover's VRLA AGM High Rate product guide (REV B), model table (columns Part No., Volts, Watts per Cell 15-min, C20, C10, C1, Length, Width, Height, Weight, Terminal). The Terminal column reads F13M5; Discover sells a model with each listed terminal type.
Where: Model table, VRLA AGM HIGH RATE, row D12-120W
Printed as "D12-120W 12 120 30 27 23 165 125 175 8.80 F13M5" in Discover's VRLA AGM High Rate product guide (REV B), model table (columns Part No., Volts, Watts per Cell 15-min, C20, C10, C1, Length, Width, Height, Weight, Terminal). C20 (20-hour) capacity 30 Ah. The same row prints C10 27 Ah and C1 23 Ah, and 120 watts per cell for a 15-minute discharge. Lead-acid capacity depends on the discharge rate.
Where: Model table, VRLA AGM HIGH RATE, row D12-120W
W 125 × H 175 × L 165 mm / W 4.92 × H 6.89 × L 6.5 in converted
Printed as "D12-120W 12 120 30 27 23 165 125 175 8.80 F13M5" in Discover's VRLA AGM High Rate product guide (REV B), model table (columns Part No., Volts, Watts per Cell 15-min, C20, C10, C1, Length, Width, Height, Weight, Terminal). Length 165 mm, width 125 mm, height 175 mm; the guide notes that the height is the case only and does not include the terminals.
Where: Model table, VRLA AGM HIGH RATE, row D12-120W
3.61 L* (Calculated enclosure volume: W × H × D in mm ÷ 1,000,000)W: 125 × H: 175 × L: 165 mm / W: 4.92 × H: 6.89 × L: 6.5 in8.8 kg / 19 lb
Evidence score
Research pending0% documented
The Evidence score uses the priorities you choose. It counts published documents, such as certificates and warranty terms, and it compares a documented figure with the best documented figure of the same kind. It does not count owner reviews, and it is not a verdict on product quality or on how many people have reviewed it. A low score can mean little is documented, or that a documented figure is below the best of its kind. Undisclosed data scores 0.
Missing for this product: Certificates evidence needed; Warranty term needed; Warranty energy disclosure evidence needed; Lifetime / capacity evidence needed; Cell model disclosure evidence needed.
12 V · Format not recorded · Rated capacity
The warranty term and the lifetime energy are each scored against the best documented value for a home storage battery: a value earns its share of that best, times the weight. A documented value always earns points; an undisclosed one earns 0.
Research pending, 0 points: Certificates, Warranty term, Warranty energy disclosure, Lifetime / capacity, Cell model disclosure.
Computed from public specifications and evidence records. Warranty duration is not service quality; certificate evidence points are not a safety rating. Compatibility and installation limits still apply.
Discover Battery's own product guide for its VRLA AGM High Rate batteries, captured on October 13, 2026 from assets.discoverbattery.com, where each model's product page links it; revision REV B as printed (the file name carries the date 2020-08-31). Its model table prints Part No., Volts, Watts per Cell 15-min, C20, C10, C1, Length, Width, Height, Weight, Terminal for every model of the line. Manufacturer claims, not independent tests.
Archived copies
Archived copy of a document published by Discover Battery. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Earlier revisions, archived captures and copies published by someone other than the manufacturer. Every one stays reachable.
Archived documents
Discover VRLA AGM High Rate product guide (REV B)
Archived copy of a document published by Discover Battery. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
No sourced accessories or replacement parts listed yet.
Model history
Model identity
Model
D12-120W
No historical observations recorded yet.
Other recorded fields
Field
Value
Conditions
Source
Evidence breakdown
method version: 0.21-personal
documented pct: 0
basis: nominal
missing:
Certificates evidence needed
Warranty term needed
Warranty energy disclosure evidence needed
Lifetime / capacity evidence needed
Cell model disclosure evidence needed
criteria:
key: certificateEvidence
label: Certificates
value: 0
unit: evidence points
shown: Research pending
shown detail: Unknown
state: pending
points: 0
ceiling: 45
weight: 45
share: 0
covered: no
missing: yes
folded: yes
reason: Unknown
reason text: Unknown
note: No qualifying applicable evidence recorded. This is not proof that certification is absent. Applies: UL 1973; CEC not applicable to 12 V / 24 V / 36 V DC modules; UL 9540 not applicable to 12 V / 24 V / 36 V DC modules.
display note: Unknown
Sources: No source on record
key: years
label: Warranty term
value: Unknown
unit: years
shown: Research pending
shown detail: Unknown
state: pending
points: 0
ceiling: 20
weight: 20
share: Unknown
covered: no
missing: yes
folded: yes
reason: undocumented
reason text: Not documented. Undisclosed data scores 0.
note: Not documented.
display note: Unknown
Sources: No source on record
key: throughputEvidence
label: Warranty energy disclosure
value: 0
unit: evidence points
shown: Research pending
shown detail: Unknown
state: pending
points: 0
ceiling: 10
weight: 10
share: 0
covered: no
missing: yes
folded: yes
reason: Unknown
reason text: Unknown
note: No qualifying quantified warranty energy recorded. This is an evidence gap, not a performance judgment.
display note: Unknown
Sources: No source on record
key: lifetime
label: Lifetime / capacity
value: Unknown
unit: MWh/kWh
shown: Research pending
shown detail: Unknown
state: pending
points: 0
ceiling: 20
weight: 20
share: Unknown
covered: no
missing: yes
folded: yes
reason: undocumented
reason text: Not documented. Undisclosed data scores 0.
note: Not published. No lifetime-production bonus.
display note: Unknown
Sources: No source on record
key: cellDisclosure
label: Cell model disclosure
value: 0
unit: disclosure points
shown: Research pending
shown detail: Unknown
state: pending
points: 0
ceiling: 5
weight: 5
share: 0
covered: no
missing: yes
folded: yes
reason: Unknown
reason text: Unknown
note: A sourced cell manufacturer and model are needed. Grade A, chemistry and cell capacity alone do not identify a cell model.