Printed as "Terminals are button-type, M8 female" in Discover Energy Systems' 14-24-2800 / 12-36-6700 / 12-48-6650 Operating Manual For Motive Power Applications (805-0001 REV K), section 5.4 Installation. The specification table prints "Terminal M8" with an M8 stainless steel bolt, flat washer and lock washer supplied.
W 347.5 × H 276 × D 329.5 mm / W 13.68 × H 10.9 × D 12.97 in converted
Printed as "Battery Dimensions (HxWxD) 276 x 347.5 x 329.5 mm" in Discover Energy Systems' 14-24-2800 / 12-36-6700 / 12-48-6650 Operating Manual For Motive Power Applications (805-0001 REV K), 14-24-2800 Technical Specifications, Mechanical Specifications. Height by width by depth as printed.
Where: PDF page 12, 14-24-2800 Technical Specifications, Mechanical Specifications
Battery can be strapped in place with non-conductive nylon straps
Printed as "Battery can be strapped in place with non-conductive nylon straps" in the Discover Energy Systems 14-24-2800 / 12-36-6700 / 12-48-6650 Operating Manual For Motive Power Applications (805-0001 REV K) (page 7, 5.3 Securing Battery). Section 5.3 adds hold-down brackets at the base only for the 12-36-6700 and 12-48-6650.
Printed as "Isolated USB and CAN communication" in Discover Energy Systems' 14-24-2800 / 12-36-6700 / 12-48-6650 Operating Manual For Motive Power Applications (805-0001 REV K), section 3.1 Integrated Battery Management System, Communication Ports.
Where: PDF page 5, section 3.1 Integrated Battery Management System, Communication Ports
Printed as "Enclosure IP Rating IP 55" in Discover Energy Systems' 14-24-2800 / 12-36-6700 / 12-48-6650 Operating Manual For Motive Power Applications (805-0001 REV K), 14-24-2800 Technical Specifications, Mechanical Specifications.
Where: PDF page 12, 14-24-2800 Technical Specifications, Mechanical Specifications
Printed as "Nominal Voltage 25.6 V" in Discover Energy Systems' 14-24-2800 / 12-36-6700 / 12-48-6650 Operating Manual For Motive Power Applications (805-0001 REV K), 14-24-2800 Technical Specifications, Electrical Specifications.
Where: PDF page 12, 14-24-2800 Technical Specifications, Electrical Specifications
Printed as "Do not install AES LiFePO4 batteries in series." in Discover Energy Systems' 14-24-2800 / 12-36-6700 / 12-48-6650 Operating Manual For Motive Power Applications (805-0001 REV K), section 5 Installation, caution. The manual tells installers to select the AES model that matches the system voltage instead.
Where: PDF page 6, section 5 Installation, caution
Integrated BMS with solid state relay; internal fuse for backup over-current protection (150 A on hardware 0.0.0.1, 200 A on hardware 0.0.0.2)
Printed as "Hardware 0.0.0.1 150 A Hardware 0.0.0.2 200 A"; "Battery Management System (BMS) Integrated, with Solid State Relay (SSR)" in the Discover Energy Systems 14-24-2800 / 12-36-6700 / 12-48-6650 Operating Manual For Motive Power Applications (805-0001 REV K) (page 12, 14-24-2800 TECHNICAL SPECIFICATIONS, Fuse and Operational Specifications rows). Section 3.3: the BMS opens its internal relay to protect against operation outside maximum specifications.
Where: PDF page 12, 14-24-2800 TECHNICAL SPECIFICATIONS, Fuse and Operational Specifications rows
Printed as "Nominal Energy 2816 Wh" in Discover Energy Systems' 14-24-2800 / 12-36-6700 / 12-48-6650 Operating Manual For Motive Power Applications (805-0001 REV K), 14-24-2800 Technical Specifications, Electrical Specifications. The manual prints the figure in watt hours; it is shown here in kilowatt hours.
Where: PDF page 12, 14-24-2800 Technical Specifications, Electrical Specifications
Printed as "recommended torque is 9.0 Nm (6.64 ft-lb)" in Discover Energy Systems' 14-24-2800 / 12-36-6700 / 12-48-6650 Operating Manual For Motive Power Applications (805-0001 REV K), section 5.4 Installation. Printed as "Terminal Torque 9.0 Nm +/- 3" there as well. The second quote is the Terminal Torque row of the 14-24-2800 specification table (PDF page 12), with its printed tolerance.
Printed as "Isolated USB" in Discover Energy Systems' 14-24-2800 / 12-36-6700 / 12-48-6650 Operating Manual For Motive Power Applications (805-0001 REV K), 14-24-2800 Technical Specifications, Operational Specifications, Communication Ports. Printed as "Isolated CAN (AEBus)" there as well.
Where: PDF page 12, 14-24-2800 Technical Specifications, Operational Specifications, Communication Ports
Printed as "Continuous Discharge Current* 110 Adc 150 Adc 130 Adc" in Discover Energy Systems' 14-24-2800 / 12-36-6700 / 12-48-6650 Operating Manual For Motive Power Applications (805-0001 REV K), section 2.1 Maximum Battery Operating Limits table, 14-24-2800 column. The first figure is the 14-24-2800 column. The BMS disconnects the battery above this limit; the manual adds that the effects of AC ripple must be considered.
Where: PDF page 4, section 2.1 Maximum Battery Operating Limits table, 14-24-2800 column
Printed as "Charge Temperature Range 0°C/45°C (32°F/113°F)" in Discover Energy Systems' 14-24-2800 / 12-36-6700 / 12-48-6650 Operating Manual For Motive Power Applications (805-0001 REV K), 14-24-2800 Technical Specifications, Mechanical Specifications.
Where: PDF page 12, 14-24-2800 Technical Specifications, Mechanical Specifications
Printed as "Storage Temperature Range -20°C/45°C (-4°F/113°F)" in Discover Energy Systems' 14-24-2800 / 12-36-6700 / 12-48-6650 Operating Manual For Motive Power Applications (805-0001 REV K), 14-24-2800 Technical Specifications, Mechanical Specifications.
Where: PDF page 12, 14-24-2800 Technical Specifications, Mechanical Specifications
External fusing sized to protect the circuit and circuit cabling
Printed as "External fusing should be sized correctly to protect the circuit and circuit cabling." in the Discover Energy Systems 14-24-2800 / 12-36-6700 / 12-48-6650 Operating Manual For Motive Power Applications (805-0001 REV K) (page 5, 3.2 Internal Battery Fuse).
Printed as "Discharge Temperature Range -20°C/50°C (-4°F/122°F)" in Discover Energy Systems' 14-24-2800 / 12-36-6700 / 12-48-6650 Operating Manual For Motive Power Applications (805-0001 REV K), 14-24-2800 Technical Specifications, Mechanical Specifications.
Where: PDF page 12, 14-24-2800 Technical Specifications, Mechanical Specifications
Printed as "Charge sources with compliant J1939 Canbus communications can be used directly with AEBus." in the Discover Energy Systems 14-24-2800 / 12-36-6700 / 12-48-6650 Operating Manual For Motive Power Applications (805-0001 REV K) (page 9, 5.7 Configuration with Power Conversion and Monitoring Devices). Other closed-loop communication needs the LYNK Gateway device from Discover Energy Systems.
Where: PDF page 9, 5.7 Configuration with Power Conversion and Monitoring Devices
Printed as "Recommended low voltage cut off: 24 V | 36 V | 48 V" in Discover Energy Systems' 14-24-2800 / 12-36-6700 / 12-48-6650 Operating Manual For Motive Power Applications (805-0001 REV K), section 6.4 Discharging. A recommended setting; the first figure is the 14-24-2800, matching the order of the models in the charge table above it.
Printed as "Charge Voltage 27.2 V" in Discover Energy Systems' 14-24-2800 / 12-36-6700 / 12-48-6650 Operating Manual For Motive Power Applications (805-0001 REV K), 14-24-2800 Technical Specifications, Electrical Specifications. Section 6.3 gives the same figure as the absorption voltage of the open loop charge curve.
Where: PDF page 12, 14-24-2800 Technical Specifications, Electrical Specifications
31.6 L* (Calculated enclosure volume: W × H × D in mm ÷ 1,000,000)W: 347.5 × H: 276 × D: 329.5 mm / W: 13.68 × H: 10.9 × D: 12.97 in40 kg / 88 lb0.09 kWh/L* (Rated or usable capacity shown on this card ÷ enclosure volume)
Evidence score
Research pending0% documented
The Evidence score uses the priorities you choose. It counts published documents, such as certificates and warranty terms, and it compares a documented figure with the best documented figure of the same kind. It does not count owner reviews, and it is not a verdict on product quality or on how many people have reviewed it. A low score can mean little is documented, or that a documented figure is below the best of its kind. Undisclosed data scores 0.
Missing for this product: Certificates evidence needed; Warranty term needed; Warranty energy disclosure evidence needed; Lifetime / capacity evidence needed; Cell model disclosure evidence needed.
24 V · Format not recorded · Rated capacity
The warranty term and the lifetime energy are each scored against the best documented value for a home storage battery: a value earns its share of that best, times the weight. A documented value always earns points; an undisclosed one earns 0.
Research pending, 0 points: Certificates, Warranty term, Warranty energy disclosure, Cell model disclosure.
Computed from public specifications and evidence records. Warranty duration is not service quality; certificate evidence points are not a safety rating. Compatibility and installation limits still apply.
Location: PDF page 1, cover and contents; PDF pages 12 to 14, technical specifications per model
Retrieved Oct 1, 2026
Discover Energy Systems' own operating manual for the 14-24-2800, 12-36-6700 and 12-48-6650 AES batteries, captured 1 October 2026 from discoverenergysys.com; revision 805-0001 REV K as printed; its cover and its three technical specification pages name these three models. Manufacturer instructions, not independent tests.
Archived copies
Archived copy of a document published by Discover Energy Systems. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Archived copy of a document published by Discover. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Archived copy of a document published by Discover. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Archived copy of a document published by Discover. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Archived copy of a document published by Discover. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Archived copy of a document published by Discover. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Archived copy of a document published by Discover. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Discover Energy Systems 14-24-2800 / 12-36-6700 / 12-48-6650 Operating Manual For Motive Power Applications (805-0001 REV K)
Archived copy of a document published by Discover Energy Systems. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
No sourced accessories or replacement parts listed yet.
Model history
Model identity
Model
14-24-2800
No historical observations recorded yet.
Other recorded fields
Field
Value
Conditions
Source
Evidence breakdown
method version: 0.21-personal
documented pct: 0
basis: nominal
missing:
Certificates evidence needed
Warranty term needed
Warranty energy disclosure evidence needed
Lifetime / capacity evidence needed
Cell model disclosure evidence needed
criteria:
key: certificateEvidence
label: Certificates
value: 0
unit: evidence points
shown: Research pending
shown detail: Unknown
state: pending
points: 0
ceiling: 45
weight: 45
share: 0
covered: no
missing: yes
folded: yes
reason: Unknown
reason text: Unknown
note: No qualifying applicable evidence recorded. This is not proof that certification is absent. Applies: UL 1973; CEC not applicable to 12 V / 24 V / 36 V DC modules; UL 9540 not applicable to 12 V / 24 V / 36 V DC modules.
display note: Unknown
Sources: No source on record
key: years
label: Warranty term
value: Unknown
unit: years
shown: Research pending
shown detail: Unknown
state: pending
points: 0
ceiling: 20
weight: 20
share: Unknown
covered: no
missing: yes
folded: yes
reason: undocumented
reason text: Not documented. Undisclosed data scores 0.
note: Not documented.
display note: Unknown
Sources: No source on record
key: throughputEvidence
label: Warranty energy disclosure
value: 0
unit: evidence points
shown: Research pending
shown detail: Unknown
state: pending
points: 0
ceiling: 10
weight: 10
share: 0
covered: no
missing: yes
folded: yes
reason: Unknown
reason text: Unknown
note: No qualifying quantified warranty energy recorded. This is an evidence gap, not a performance judgment.
display note: Unknown
Sources: No source on record
key: lifetime
label: Lifetime / capacity
value: Unknown
unit: MWh/kWh
shown: Research pending
shown detail: Unknown
state: pending
points: 0
ceiling: 20
weight: 20
share: Unknown
covered: no
missing: yes
folded: no
reason: undocumented
reason text: Not documented. Undisclosed data scores 0.
note: Not published. No lifetime-production bonus.