Charged ReviewsSaved 0Compare 0Login

Charged Reviews · Quick reference

Deye SE-F16 Max-6 residential battery (16 kWh, 51.2 V)

Brand
Deye
Model
SE-F16 Max-6
SKU / part number
?
Category
Batteries

chargedreviews.com/batteries/deye-se-f16-max-6

Energy and chemistry

Nominal voltage
51.2 V [1]
Rated capacity
314 Ah [1]
Nominal energy
16 kWh [1]
Usable energy
16 kWh [1]
Chemistry
LiFePO4 [1]
Cell format
?

Charge and discharge

Continuous charge current
160 A [1]
Continuous discharge current
200 A [1]
Maximum charge current
160 A [1]
Maximum discharge current
200 A [1]
Peak charge current
280 A [1]
Peak discharge current
240 A [1]
Continuous output power
?
Peak output
240 A for 10 s [1]
Maximum charge voltage
?
Charge cutoff voltage
?
Discharge cutoff voltage
?

BMS and communication

BMS continuous current
?
Communication protocols
CAN2.0; RS485; Bluetooth [1]
Wireless monitoring
Bluetooth [1]
Inverter compatibility
?

Operating temperature

Charging temperature
-20 to 55 °C / -4 to 131 °F converted [1]
Discharging temperature
-20 to 55 °C / -4 to 131 °F converted [1]
Storage temperature
0 to 35 °C / 32 to 95 °F converted [1]
Self-heating
?

Mechanical and mounting

Dimensions
W 464 × H 914 × D 244.5 mm / W 18.3 × H 36 × D 9.63 in converted [1]
Weight
120 kg / 265 lb converted [1]
Terminals
M8 [1]
Mounting / format
Wall-mounted or floor-mounted [1]
Enclosure rating (IP)
IP65/NEMA 3R [1]

Installation (from the manual)

Torque

Main terminal torque
12 to 19 N·m [1]
Communication terminal torque
?
Ground terminal torque
1.6 to 2.2 N·m [1]

Protection

Fuse or breaker
Built-in circuit breaker [1]

Grounding

Grounding
Factory-installed M4×8 grounding bolt on the battery; other end of the earthing cable to earth ground [1]

Communication

Communication ports
The PCS port is connected to the Power Conversion Unit via the communication cable.; If the battery does not act as the master: The IN port is connected to the OUT port of the previous battery pack via the communication cable; If the battery acts as the master: The OUT port is connected to the IN port of the next battery pack via the communication cable.; If the battery does not act as the master: The OUT port is connected to the IN port of the next battery pack via a communication cable, or the OUT port is left unconnected. [1]
Address / DIP setting
?

Not in the manual: Conductors, Clearances and orientation

System limits

Maximum parallel units
32 count [1]
Series connection
?
Maximum system energy
?
Page 1 of 2 · Installation values · ? means nothing is recordedAggregated, often community-reported information, not official documentation. Do not rely on it for installation, purchase or compliance decisions; always confirm values with the manufacturer’s official documentation. Charged Reviews accepts no responsibility for errors.

Charged Reviews · Quick reference

Deye SE-F16 Max-6 residential battery (16 kWh, 51.2 V) · SE-F16 Max-6

Warranty

Warranty term?
Warranty cycle limit?
Warranted throughput?
Capacity retention?
Cycle rating8,000 cycles[1]
Estimated throughput?
Coverage starts?
Coverage conditions?
Remedy?
Labor and shipping?
Transfer to another owner?
Registration?

Certifications and listings

UL 1973Claimed present at observation [1]
UL 9540?
UL 9540AClaimed present at observation [1]
UN 38.3Claimed present at observation [1]
IEC 62619?
CE?
FCCClaimed present at observation [1]
UL9540A-DCClaimed present at observation [1]

Documents and sources

  1. Deye ESS User Manual, SE-F16 Max-6, North America (EN, FR), V03 Manufacturer user manual (PDF) · Revision V03 · Checked Sep 27, 2026 https://deye.com/wp-content/uploads/2026/09/deye-ess-user-manual-se-f16-max-6-naen-fr-v03_20260810.pdf

Unofficial reference. Information may be incorrect. This sheet aggregates the public sources listed above, much of it community-reported. It is not official manufacturer documentation, not an installation guide and not a compliance record. Community-reported values are checked against official manufacturer information before publication; we cannot guarantee accuracy or completeness. Do not rely on this sheet for installation, purchase or compliance decisions: always confirm every value with the manufacturer’s official documentation before buying, wiring or installing equipment. Charged Reviews accepts no responsibility for errors or omissions. Manufacturers can submit documents or corrections.

Page 2 of 2 · Charged Reviews LLC · chargedreviews.com/batteries/deye-se-f16-max-6Some links pay us a commission. That does not affect what we record.