About brandNingbo Deye Technology Co., Ltd. of Beilun, Ningbo, China makes hybrid inverters and lithium iron phosphate energy storage, from wall-mounted residential packs to rack and cabinet systems for small commercial sites.
SKU detail
conditions: No SKU or part number distinct from the model name "GE-F60" is printed in the manual or on the product page.
Printed as "Nominal 100 Peak Discharge (2 mins"; "125 Max. charging/discharging efficiency 91%" in the Deye ESS User Manual, GE-F60, EU/EN, V06 (page 69, section 12.1 System Parameter). Two minutes expressed as 120 seconds.
Printed as "Installation Style Floor-Mounted Warranty 10 years" in the Deye ESS User Manual, GE-F60, EU/EN, V06 (page 69, section 12.1 System Parameter).
Charged Reviews classified this product from the documents it is based on. It is our own grouping, not a manufacturer claim.
Printed as "Its IP55-rated enclosure houses the battery modules in a floor-mounted format.". Classified as Industrial cabinet from the maker's own words for this model (PM decision, October 13, 2026: an industrial battery with cabinet or enclosure wording is Industrial cabinet).
Printed as "The EU version provides 55.29 kWh of usable energy with a recommended depth of discharge of 90%." on Deye's own GE-F60 product page (deye.com, captured September 28, 2026). The page prints this figure for the EU version only; the AU version's figure belongs to that version.
Where: Deye GE-F60 product page, "Choose the Version for Your Market" section
PCS COM: communication with charging and discharging equipment; IN COM: from the previous GE-F-PDU; OUT COM: to the next GE-F-PDU; COMM1: communication with the cabinet; USB: BMS upgrade and storage expansion interface
Printed as "⑪PCS COM Communication interface with charging and discharging equipment"; "⑩IN COM Connection position with previous GE-F-PDU communication input"; "⑨OUT COM Connection position with next GE-F-PDU communication output"; "⑬COMM1 Communicative connection with the cabinet"; "⑧USB BMS upgrade interface and storage expansion interface" in the Deye ESS User Manual, GE-F60, EU/EN, V06 (page 16, high-voltage control box interface description).
Where: PDF page 16, high-voltage control box interface description
Printed as "Operating Temperature Range(°C) Charge: 0~55/Discharge: -20~55" in the Deye ESS User Manual, GE-F60, EU/EN, V06 (page 69, section 12.1 Battery Technical Specification).
Where: PDF page 69, section 12.1 Battery Technical Specification
Printed as "Charge/Discharge Current (A) 2 Recommend 50 Nominal 100" in the Deye ESS User Manual, GE-F60, EU/EN, V06 (page 69, section 12.1 System Parameter).
Printed as "Operating Temperature Range(°C) Charge: 0~55/Discharge: -20~55" in the Deye ESS User Manual, GE-F60, EU/EN, V06 (page 69, section 12.1 Battery Technical Specification).
Where: PDF page 69, section 12.1 Battery Technical Specification
1,853.26 L* (Calculated enclosure volume: W × H × D in mm ÷ 1,000,000)W: 783 × H: 2,235 × D: 1,059 mm / W: 30.8 × H: 87.99 × D: 41.69 in1,280 kg / 2,822 lb0.03 kWh/L* (Rated or usable capacity shown on this card ÷ enclosure volume)
Evidence score
17/100Missing details40% documented
The Evidence score uses the priorities you choose. It counts published documents, such as certificates and warranty terms, and it compares a documented figure with the best documented figure of the same kind. It does not count owner reviews, and it is not a verdict on product quality or on how many people have reviewed it. A low score can mean little is documented, or that a documented figure is below the best of its kind. Undisclosed data scores 0.
Missing details. This number counts only the evidence recorded so far. The source review for this product is not finished, or the maker has not disclosed enough, so the number can only go up.
Missing for this product: Certificates evidence needed; Warranty energy disclosure evidence needed; Cell model disclosure evidence needed.
Industrial/Commercial ESS · High voltage · 30 to 100 kWh · Rated capacity
The warranty term and the lifetime energy are each scored against the best documented value for a home storage battery: a value earns its share of that best, times the weight. A documented value always earns points; an undisclosed one earns 0.
Research pending, 0 points: Certificates, Warranty energy disclosure, Cell model disclosure.
Computed from public specifications and evidence records. Warranty duration is not service quality; certificate evidence points are not a safety rating. Compatibility and installation limits still apply.
Printed as part of "Battery Module Certification CE, IEC62619, IEC62040, UN38.3" in the Certification row of Deye's GE-F60 user manual. Recorded exactly as printed; the document names no certifying body, certificate number or scope for this standard, no certificate document was read, and no issuer record was checked.
IEC62040manufacturer claimpresent at observation[1]
Scope
unresolved document set
Covered models
deye-ge-f60-eu
Limitations
Printed as part of "Battery Module Certification CE, IEC62619, IEC62040, UN38.3" in the Certification row of Deye's GE-F60 user manual. Recorded exactly as printed; the document names no certifying body, certificate number or scope for this standard, no certificate document was read, and no issuer record was checked.
IEC62619manufacturer claimpresent at observation[1]
Scope
unresolved document set
Covered models
deye-ge-f60-eu
Limitations
Printed as part of "Battery Module Certification CE, IEC62619, IEC62040, UN38.3" in the Certification row of Deye's GE-F60 user manual. Recorded exactly as printed; the document names no certifying body, certificate number or scope for this standard, no certificate document was read, and no issuer record was checked.
Printed as part of "Battery Module Certification CE, IEC62619, IEC62040, UN38.3" in the Certification row of Deye's GE-F60 user manual. Recorded exactly as printed; the document names no certifying body, certificate number or scope for this standard, no certificate document was read, and no issuer record was checked.
CEManufacturer claim · unresolved document setClaimedListed when checked
Printed as part of "Battery Module Certification CE, IEC62619, IEC62040, UN38.3" in the Certification row of Deye's GE-F60 user manual. Recorded exactly as printed; the document names no certifying body, certificate number or scope for this standard, no certificate document was read, and no issuer record was checked.
IEC62619Manufacturer claim · unresolved document setClaimedListed when checked
Printed as part of "Battery Module Certification CE, IEC62619, IEC62040, UN38.3" in the Certification row of Deye's GE-F60 user manual. Recorded exactly as printed; the document names no certifying body, certificate number or scope for this standard, no certificate document was read, and no issuer record was checked.
IEC62040Manufacturer claim · unresolved document setClaimedListed when checked
Printed as part of "Battery Module Certification CE, IEC62619, IEC62040, UN38.3" in the Certification row of Deye's GE-F60 user manual. Recorded exactly as printed; the document names no certifying body, certificate number or scope for this standard, no certificate document was read, and no issuer record was checked.
UN38.3Manufacturer claim · unresolved document setClaimedListed when checked
Printed as part of "Battery Module Certification CE, IEC62619, IEC62040, UN38.3" in the Certification row of Deye's GE-F60 user manual. Recorded exactly as printed; the document names no certifying body, certificate number or scope for this standard, no certificate document was read, and no issuer record was checked.
Captured by scripts/prepare-brand-sweep-sep21.mjs on 2026-09-28.
Location: 12.1 System Parameter
Retrieved Sep 27, 2026
Deye's own user manual for GE-F60, EU English edition, version 06, linked from the product page, captured September 28, 2026. Its own "12.1 System Parameter" table prints one column for the single model GE-F60.
Archived copies
Archived copy of a document published by Ningbo Deye ESS Technology Co., Ltd.. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Earlier revisions, archived captures and copies published by someone other than the manufacturer. Every one stays reachable.
Archived documents
Deye ESS User Manual, GE-F60, EU/EN, V06
Archived copy of a document published by Ningbo Deye ESS Technology Co., Ltd.. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
No sourced accessories or replacement parts listed yet.
Model history
Model identity
Model
GE-F60
Manufacturer SKU unknown · EU market
No historical observations recorded yet.
Other recorded fields
Field
Value
Conditions
Source
Evidence breakdown
method version: 0.21-personal
documented pct: 40
basis: nominal
missing:
Certificates evidence needed
Warranty energy disclosure evidence needed
Cell model disclosure evidence needed
criteria:
key: certificateEvidence
label: Certificates
value: 0
unit: evidence points
shown: CE · IEC62619 +2
shown detail: Research pending
state: pending
points: 0
ceiling: 45
weight: 45
share: 0
covered: no
missing: yes
folded: yes
reason: Unknown
reason text: Unknown
note: No qualifying applicable evidence recorded. This is not proof that certification is absent. Applies: UL 9540; UL 1973; CEC not assessed for commercial and industrial equipment in this catalog. UL 9540A is recorded but not scored: a thermal-runaway test method, recorded as a documented report and never scored as a listing.